A house using 4000 kWh a year: kWp and panels (Krakow)
How many kWp and panels a house using 4000 kWh a year needs in Krakow. PVGIS yield, panel count at 450, 550 and 640 W, how much you use on site and the roof area.
A house using 4000 kWh a year needs about 3.7 kWp in Krakow: 7 panels of 550 W (3.85 kWp, 4147 kWh a year) or 6 of 640 W. The PVGIS yield per kWp is 1077 kWh a year, so the sum is 4000 ÷ 1077. About 35 % is used in the house. The calculation is preliminary.
Below is the whole calculation for one address and one consumption. Every figure comes from the same engine functions behind the free system size calculator, so you can repeat it with your own data. The general formula and a table for several consumptions are in the article on how many kW of solar a house needs, and the link between power and panel count in panels per kW.
Starting data
| Item | Value |
|---|---|
| Place | Krakow, 50.06° N, 19.94° E |
| Consumption | 4000 kWh a year, the engine's "family" profile |
| Roof | facing south, tilt 35° |
| Yield | PVGIS, typical year from 2014 to 2023, system losses 14 % |
| Yield per 1 kWp | 1077.1 kWh a year |
| System | no battery, grid-tied inverter |
Power: consumption ÷ yield
4000 kWh ÷ 1077.1 kWh/kWp = 3.71 kWp. That is what it takes for the system to produce over a year what the house uses. The panel count is rounded up to whole panels:
| Panel power | Panels | System power | Yearly output |
|---|---|---|---|
| 450 W | 9 | 4.05 kWp | 4362 kWh |
| 550 W | 7 | 3.85 kWp | 4147 kWh |
| 640 W | 6 | 3.84 kWp | 4136 kWh |
A 550 W panel measures 2350 × 1100 mm and a 640 W panel (Tongwei TWMNH-66HD) 2382 × 1134 mm. Seven 550 W panels take about 18.6 m² of roof with the gaps, six 640 W panels about 16.6 m².
How much of it you use on site
Producing over a year what you consume is not the same as covering your consumption. The engine runs the balance hour by hour: the panels produce at midday, the house consumes in the morning and evening.
| Option | 550 W panels | Power | Output | Used on site | Share of consumption covered | Bought from grid | Surplus to grid |
|---|---|---|---|---|---|---|---|
| For own use | 2 | 1.10 kWp | 1185 kWh | 82 % | 24 % | 3034 kWh | 219 kWh |
| For the whole yearly consumption | 7 | 3.85 kWp | 4147 kWh | 35 % | 37 % | 2531 kWh | 2678 kWh |
Two conclusions. First, a system sized to "zero over the year" covers only 37 % of consumption without a battery, because most of the output (2678 kWh) goes to the grid during the day while the house still buys 2531 kWh in the evening and in winter. Second, the small option uses almost everything itself but covers only a quarter of yearly consumption. Which one makes sense depends on what grid electricity costs and what the surplus earns: work it out in the payback calculator, and an example for 10 kWp is in the article payback of a 10 kWp system.
The engine also gives the lower end of the range: below 1.65 kWp (3 panels of 550 W) the system never makes more in any month than the house uses that month. The range from 1.65 to 3.85 kWp is a sensible bracket for this house.
What changes the result
- Orientation and tilt. East or west give a lower yield per kWp, so more kWp is needed for the same 4000 kWh. Change the tilt and direction in the calculator.
- Battery. A battery raises the share of energy used on site but does not change the power needed for the yearly consumption. How much battery is needed is covered in the article on battery capacity.
- Consumption. A heat pump or an electric car changes the consumption and with it the system size.
- Inverter. The type and power of the inverter depend on the panel power and on whether you want a battery: see the article on inverter types.
How to repeat the calculation
- Open the system size calculator, find Krakow with the address search (or enter 50.06 and 19.94), set consumption 4000 kWh a year, tilt 35° and a south-facing roof.
- The goal "Saving on bills" gives a system without a battery. Pick a panel and the calculator gives the number of panels.
- Compare with the table above. The calculator uses PVGIS when it answers and otherwise an approximate formula that gives a slightly different value (about 1115 kWh/kWp for Krakow).
The calculation is preliminary. The yield and the balance depend on the PVGIS data and the assumed consumption profile, and a house's real hourly consumption can differ. Before installation the calculation must be checked by a qualified engineer, and the installation must be done only by a qualified electrician.
FAQ
How many panels does a house using 4000 kWh a year need in Krakow?
Seven panels of 550 W (3.85 kWp) or six of 640 W. It comes from dividing 4000 kWh by the yield of 1077 kWh per kWp, which is 3.71 kWp, rounded up to whole panels.
Does a system sized for the whole yearly consumption cover the whole bill?
No. Without a battery about 37 % of consumption is covered directly from the panels, the house buys the rest from the grid in the evening and in winter, and the midday surplus goes to the grid.
Where do the 1077 kWh per kWp come from?
From PVGIS, the free tool of the European Commission's Joint Research Centre: a typical year from 2014 to 2023 for 50.06° N, 19.94° E, tilt 35° facing south, losses 14 %.