What size solar system does a house need (in kW)
What size solar system your house needs: annual consumption ÷ the yield of 1 kWp where you live, a table for 2,400–9,000 kWh, panels, inverter and roof area.
A solar system is sized from consumption: kWp = annual consumption, kWh ÷ specific yield, kWh per kWp per year. In Ukraine, 1 kWp of panels facing south at the optimal tilt produces roughly 1,050–1,350 kWh a year depending on the region; in Central Europe it is about 950–1,100, in Spain about 1,400–1,700. A house using 4,000 kWh a year in Kyiv needs about 3.6 kWp — 8 panels of 450 W or 7 of 550 W. Below are the formula, yields by region, a table for typical houses, the inverter choice and the roof area. You can calculate your own case for your address in the solar system size calculator.
The formula: consumption ÷ yield
- Annual consumption. Add up 12 months of meter readings. One month will not do: consumption is higher in winter and lower in summer, and the system would come out too large or too small.
- Specific yield. How many kilowatt-hours a year 1 kWp of panels gives at your address with your tilt and orientation. It already includes the weather, temperature and typical system losses.
- System size. Divide the first by the second and round to a whole number of panels.
Example. 6,000 kWh ÷ 1,100 kWh/kWp ≈ 5.5 kWp. Panels of 450 W: 5,500 ÷ 450 ≈ 12; of 550 W: 5,500 ÷ 550 = 10.
"kWp" (kilowatt peak) is the sum of the panels' rated power under standard test conditions. Real power in the field is almost always lower, and the specific yield already accounts for that.
How much 1 kWp produces in your region
The specific yield depends on latitude, climate, tilt and orientation. Guide values for south-facing panels at the optimal tilt, from PVGIS, for Ukraine:
| Region | Regional centres | Yield, kWh per kWp per year |
|---|---|---|
| West | Lviv, Ternopil, Ivano-Frankivsk | ≈ 1,050–1,100 |
| North and centre | Kyiv, Zhytomyr, Vinnytsia, Cherkasy | ≈ 1,100–1,150 |
| East | Poltava, Kharkiv, Dnipro | ≈ 1,150–1,250 |
| South | Odesa, Mykolaiv, Kherson, Zaporizhzhia | ≈ 1,250–1,350 |
For Kyiv our calculator takes about 1,114 kWh per kWp a year from PVGIS. You can check the value for your own location in PVGIS itself — a free tool of the European Commission's Joint Research Centre.
What changes the yield:
- Orientation. East or west gives roughly 15–20 % less per year than south, but spreads generation into the morning and evening.
- Tilt. Being 10–15° off the optimum costs a few per cent of the annual yield; panels laid flat lose more. The optimal tilt for your latitude is shown by the tilt and row spacing calculator.
- Shade. Trees, chimneys, neighbouring houses. Shade on even part of a string cuts its output by more than the shaded share of its area.
- Season. In December 1 kWp produces several times less than in June. A system that covers the whole year's consumption still takes much of its winter energy from the grid.
Table: typical houses
Calculated for a specific yield of 1,100 kWh/kWp (Ukraine's north and centre), the number of panels rounded to whole units. The area is the area of the panels alone: about 2.0 m² for a 440–450 W module and about 2.6 m² for a 550 W module.
| Annual consumption | Example | System size | ~450 W panels | ~550 W panels | Panel area |
|---|---|---|---|---|---|
| 2,400 kWh | a flat or a small house, gas cooker | ≈ 2.2 kWp | 5 (2.25 kWp) | 4 (2.2 kWp) | ≈ 10 m² |
| 4,000 kWh | a house for 3–4 people, electric cooker or water heater | ≈ 3.6 kWp | 8 (3.6 kWp) | 7 (3.85 kWp) | ≈ 16–18 m² |
| 6,000 kWh | a house with a water heater, air conditioners, a well pump | ≈ 5.5 kWp | 12 (5.4 kWp) | 10 (5.5 kWp) | ≈ 24–26 m² |
| 9,000 kWh | a house with a heat pump or an electric car | ≈ 8.2 kWp | 18 (8.1 kWp) | 15 (8.25 kWp) | ≈ 36–39 m² |
In the south, with about 1,300 kWh/kWp, the same houses need a system roughly 15 % smaller. Models of both classes are in the catalogue: 400–449 W panels and 550–599 W panels.
Why the annual total is not the whole answer
A system "sized to annual consumption" covers the year in total, not every hour. In the daytime it produces more than the house uses; in the evening and in winter, less. So what happens to the surplus matters:
- The surplus is paid for or credited. It makes sense to size the system to the whole annual consumption, or even more if the rules and the connection capacity allow.
- The surplus is not paid for. A large system will give energy to the grid for free. In that case our calculator suggests a smaller option: each additional panel should work at least half for the house.
- There is a battery. It shifts the daytime surplus into the evening, so the system can be larger than without one — but the capacity is calculated separately.
Inverter power: the panels and the peak load
The inverter is chosen by two different questions.
How many panels it can take. The panels' power (DC) is usually a little higher than the inverter's rated power (AC). The guide is a DC/AC ratio of up to 1.3; above that the inverter clips the peaks in the sunniest hours. For 5.4 kWp a 5 kW inverter fits (≈ 1.1) — see 5–6 kW inverters. For 8.1 kWp, 8 kW (≈ 1.0) or, if you knowingly accept clipping, 6 kW (≈ 1.35). For 10–12 kWp see 10–12 kW inverters.
What it must carry. A grid-tie inverter does not care about the house's peak load: the grid supplies whatever is missing. A hybrid inverter in backup mode powers the loads by itself, so its power must cover everything that runs at once, with margin for starting currents. A fridge compressor, a pump or an air conditioner draws several times its rating at start-up; the permissible short overload is in the inverter's datasheet.
Above all this sits your contract with the grid operator: the permitted connection capacity and the terms for generation. Check them before buying the inverter.
Roof area per kW
The panels alone take about 4.4 m² per kWp with 440–450 W modules and about 4.7 m² with 550 W modules. On a roof you add gaps between panels and clearances from the edges, so in practice allow 5–6 m² of roof per kWp. A 5.5 kWp system needs 28–33 m² of usable roof slope; 10 kWp, 50–60 m².
On a flat roof or on the ground the rows stand at an angle and need spacing so that the front row does not shade the back one in winter. There the plot area can be several times the panel area. How panels are mounted on different roofs is in the section mounting by roof type.
A battery is a separate question
The system size answers "how much energy a year", the battery capacity "how many hours without the grid". They are calculated separately: the battery from the load during an outage and its duration. The formula with depth of discharge and efficiency is in how to calculate battery capacity.
Step by step
- Collect the annual consumption from 12 months of bills.
- Take the specific yield for your address, tilt and orientation.
- Divide and round to whole panels of the chosen power.
- Decide whether you need backup: the inverter type depends on it — see grid-tie or hybrid inverter.
- Check that the system fits on the roof and the inverter within the permitted capacity.
- Lay the panels out into strings with frost in mind in the string calculator.
- Calculate the payback with your tariffs in the payback calculator.
Frequently asked questions
What size solar system does a 100 m² house need?
The floor area says little: consumption is what counts. A 100 m² house with gas heating may use 3,000–4,000 kWh a year, which means a system of about 2.7–3.6 kWp; with a heat pump, several times more. Take the annual consumption from your bills and calculate it in the solar system size calculator.
How many panels do I need for 5 kW?
11–12 panels of 450 W or 9–10 of 550 W. At a yield of 1,100 kWh/kWp such a system gives about 5,500 kWh a year.
How much does a 5 kW system produce in a year?
Roughly from 5,250 kWh in the west to 6,750 kWh in the south of Ukraine, facing south at the optimal tilt. East, west, a low tilt and shade reduce the figure.
Should I oversize the system?
If a heat pump, air conditioner or electric car is coming in the next few years — yes, or at least choose an inverter with headroom in PV power and number of MPPTs so you can add panels later. If the surplus is not paid for, extra capacity without a battery mostly goes to the grid for free.
How much roof space does 10 kW need?
The panels alone take about 44–47 m²; with gaps and clearances, 50–60 m² of usable roof slope.
A preliminary estimate. A qualified engineer must check it before installation.