East-west or south roof: how much less solar yield (Krakow)

How much less a solar system makes on an east-west roof than on a south roof in Krakow: PVGIS yield per kWp, panels needed for 4000 kWh a year and how much is used in the house.

By Solispec editorial3 min read

In Krakow at 35 degrees a south-facing array makes 1077 kWh per kWp a year and an east-west array (half east, half west) 841 kWh, which is 22 % less. For 4000 kWh a year that means 9 panels of 550 W instead of 7. The east-west roof covers more of the consumption, 39.0 % against 36.7 %.

The numbers come from the same engine functions behind the free system size calculator, with the PVGIS yield. What it costs and when it pays back is worked out in the payback calculator, and a full example for a south roof is in the article on a house using 4000 kWh a year.

Starting data

ItemValue
PlaceKrakow, 50.06° N
Tilt35° in every variant
YieldPVGIS, typical year from 2014 to 2023, system losses 14 %
Consumption4000 kWh a year, the "family" profile
Systemno battery, grid-tied inverter, 550 W panels
East-westhalf the panels on the east slope, half on the west

Yield per kWp

OrientationkWh per kWp a yearAgainst south
South1077.10 %
East848.6−21 %
West833.0−23 %
East and west (half each)840.8−22 %

What it means for the system size

OptionPanels of 550 WPowerOutputUsed on siteConsumption covered
South73.85 kWp4147 kWh35.4 %36.7 %
East and west94.95 kWp4162 kWh37.5 %39.0 %

To make over a year what the house uses, east-west takes 2 more panels. In return the output is spread over the morning and the evening, and a larger share of the energy is used in the house instead of going to the grid.

What changes the result

  • Tilt and azimuth. Change them in the system size calculator: a flat roof or another orientation gives other numbers.
  • Strings. On a roof with two slopes each slope usually gets its own string, which the strings calculator checks.
  • Consumption. A heat pump or an electric car changes the profile and the share used on site.

How to repeat the calculation

  1. Open the system size calculator, enter Krakow, consumption 4000 kWh a year and a tilt of 35°.
  2. Set south, then east and west, and compare the number of panels.
  3. For money, carry the power over to the payback calculator.

The calculation is preliminary. The yield and the balance depend on the PVGIS data and the assumed consumption profile, and the real hourly consumption of a house can differ. Before installation the calculation must be checked by a qualified engineer, and the installation must be done only by a qualified electrician.

FAQ

How much less does an east-west roof produce than a south roof?

In Krakow at 35 degrees, 22 % less from each kWp: 841 against 1077 kWh a year. An east slope alone makes 21 % less and a west slope alone 23 % less.

Do I need more panels on an east-west roof?

Yes. For the same 4000 kWh a year it is 9 panels of 550 W (4.95 kWp) instead of 7 (3.85 kWp).

Is east-west better for self-consumption?

In the hourly balance it is: 37.5 % of the output is used in the house against 35.4 % for south, and 39.0 % of consumption is covered against 36.7 %.

YieldStructures

News and design tips

What’s new in Solispec, changes to the standards and practical tips on designing solar power systems.

What interests you

How we handle your data: privacy policy.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate