How many solar panels you need for 5, 10, 15 and 30 kW

Panel count, roof area and weight for 5, 10, 15 and 30 kW plants, by panel class and by specific models from our catalogue, with the real module sizes rather than "about 2 m²".

By Solispec editorial7 min read

The answer to "how many panels for 10 kW" depends on one number only: the power of a single panel. The questions that follow are the ones "about 20" does not answer: how many square metres on the roof, how many kilograms on the rafters, and which inverter to take for that count. Below are tables computed from the sizes and powers of the 98 panels in our catalogue, and an explanation of how these numbers change with tilt and orientation.

The formula and what hides in it

The number of panels is the plant power divided by the power of one panel, rounded up:

n = ⌈P / W⌉, where P is the plant power in watts and W the panel's datasheet power.

10 000 / 590 = 16.95 → 17 panels. Together they give 17 × 590 = 10.03 kWp, slightly more than "10 kW". Two numbers must be kept apart here. kWp (kilowatts peak) is the total datasheet power of the panels at standard test conditions. kW of the inverter is the AC power the plant can actually deliver. Panels are usually installed 10–30 % above the inverter power, and that is normal; why, and where the limit lies, is explained in the article on the DC/AC ratio.

Table by panel class

The catalogue's panels fall into six power classes; for each class we took the median size and weight. The area is the modules' own area (length × width × count), without walkways or edge setbacks.

Panel classModels in catalogueSize and weight (median)Area of one, m²5 kW: pcs / m²10 kW: pcs / m²15 kW: pcs / m²30 kW: pcs / m²
440 W261742 × 1134 · 21.3 kg1.9812 / 23.723 / 45.435 / 69.169 / 136.3
500 W41961 × 1134 · 27.1 kg2.2210 / 22.220 / 44.530 / 66.760 / 133.4
590 W142278 × 1134 · 31.4 kg2.589 / 23.217 / 43.926 / 67.251 / 131.7
620 W172382 × 1134 · 32.5 kg2.709 / 24.317 / 45.925 / 67.549 / 132.4
650 W152382 × 1134 · 32.8 kg2.708 / 21.616 / 43.224 / 64.847 / 127.0
720 W52384 × 1303 · 37.5 kg3.117 / 21.714 / 43.521 / 65.242 / 130.5

What the table shows:

  • The area hardly depends on the class. 10 kW take 43–46 m² of modules whichever panels you choose: the efficiency of current modules is close, and a bigger panel is simply bigger. The gain of more powerful panels is in fewer clamps, cable connections and installation time, not in area.
  • The weight is 490–550 kg per 10 kW. 17 panels of 590 W weigh about 534 kg; with rails and clamps the load on the roof is computed in the mounting design, and for old rafters that is not a rhetorical question; see the article on pitched-roof mounting.
  • 720 W panels are 1303 mm wide. The 2384 × 1303 mm format does not always fit the rows of an older layout and weighs 37.5 kg; lifting it onto a roof with two people is already awkward.

Table by specific model

For 13 models that people most often search for, the brackets show the real total array power in kWp.

ModelWSize, mm5 kW10 kW15 kW30 kW
LONGi Hi-MO 6 LR5-54HTH-435M4351722 × 113412 (5.22 kWp)23 (10.01 kWp)35 (15.23 kWp)69 (30.02 kWp)
Jinko Tiger Neo JKM440N-54HL4R-V4401762 × 113412 (5.28 kWp)23 (10.12 kWp)35 (15.40 kWp)69 (30.36 kWp)
Tongwei TNC 2.0 TWMNH-48HW4704701762 × 113411 (5.17 kWp)22 (10.34 kWp)32 (15.04 kWp)64 (30.08 kWp)
Trina Vertex S+ TSM-500NEG18R.285001961 × 113410 (5.00 kWp)20 (10.00 kWp)30 (15.00 kWp)60 (30.00 kWp)
Qcells Q.TRON M-G3R.12+/BFG 5155151961 × 113410 (5.15 kWp)20 (10.30 kWp)30 (15.45 kWp)59 (30.39 kWp)
LONGi Hi-MO 6 LR5-72HTH-580M5802278 × 11349 (5.22 kWp)18 (10.44 kWp)26 (15.08 kWp)52 (30.16 kWp)
Jinko Tiger Neo JKM590N-72HL4-V5902278 × 11349 (5.31 kWp)17 (10.03 kWp)26 (15.34 kWp)51 (30.09 kWp)
Aiko Comet 2N AIKO-A620-MAH72Mw6202323 × 11349 (5.58 kWp)17 (10.54 kWp)25 (15.50 kWp)49 (30.38 kWp)
Jinko Tiger Neo JKM620N-66HL4M-V6202382 × 11349 (5.58 kWp)17 (10.54 kWp)25 (15.50 kWp)49 (30.38 kWp)
LONGi Hi-MO X10 LR7-72HVH-650M6502382 × 11348 (5.20 kWp)16 (10.40 kWp)24 (15.60 kWp)47 (30.55 kWp)
Canadian Solar TOPBiHiKu7 CS7N-705TB-AG7052384 × 13038 (5.64 kWp)15 (10.58 kWp)22 (15.51 kWp)43 (30.32 kWp)
Jinko Tiger Neo 3.0 JKM720N-66HL5-BDV7202384 × 13037 (5.04 kWp)14 (10.08 kWp)21 (15.12 kWp)42 (30.24 kWp)
Tongwei TNC TWMNF-66HD7207202384 × 13037 (5.04 kWp)14 (10.08 kWp)21 (15.12 kWp)42 (30.24 kWp)

Each model links to its catalogue page with the datasheet values: voltage, current, temperature coefficient and size. Those are the numbers needed next, for the strings and the inverter.

Tilt and orientation: the same panels, a different yield

The panel count gives the power; the kilowatt-hours a year come from tilt, azimuth and place. By PVGIS data for Kyiv (the basis our English pages share with the Ukrainian ones), one kWp gives 1114 kWh a year at the optimal 37° facing south, 1106 at 30°, 1049 at 15° and only 775 on a vertical south façade. So the difference between a "good" and the optimal tilt is within 1 %, between a flat roof and the optimum about 6 %, while a façade loses a third.

Orientation matters more. An east-west array on two slopes yields less than a south one but gives a flatter daily curve and less clipping on the inverter. For a ground plant the row spacing that keeps the rows out of each other's winter shade is computed by the tilt and row-spacing calculator.

Which power to take at all

The tables above answer "how many panels for N kW". But N is often picked at random. For a house the plant power should be derived from the yearly consumption and the hours without the grid to be covered: the system-size calculator does this hour by hour from PVGIS data for your address; the approach is described in the article how to choose the plant size.

For the typical sizes we have separate pages with panels, area, weight and yield by city: 5 kW, 10 kW, 15 kW and 30 kW.

Sources

  • Makers' datasheets of the 98 panels in the catalogue: STC power, length, width, weight. The tables are computed from these values; a class's median is taken over all models within ±10 W.
  • PVGIS v5.3 (Joint Research Centre of the European Commission, PVGIS-SARAH3 database): the yearly yield of 1 kWp in Kyiv at the optimal and at fixed tilts, 14 % system losses.
  • DSTU HD 60364-7-712:2022 — electrical installations of PV systems: string voltage and current, from which the panels' compatibility with the inverter follows.
  • DBN V.1.2-2:2006 — loads and actions: the snow and wind load on the array that, together with the panels' weight, enters the mounting design.

Frequently asked questions

How many panels are needed for 10 kW?

From 14 to 23 depending on the panel power: 23 of 440 W, 20 of 500 W, 17 of 590 or 620 W, 16 of 650 W, 14 of 720 W. The module area is 43–46 m².

How much roof space do 5 kW take?

About 21–24 m² of modules: 12 panels of 440 W, 9 of 590 W or 7 of 720 W. Edge setbacks and service walkways come on top.

How much do the panels of a 10 kW plant weigh?

About 490–550 kg without mounting: for example 17 panels of 590 W are 534 kg by the class's median weight. With the rails, the load on the rafters is computed in the mounting design.

Can more panels be installed than the inverter power?

Yes, usually 10–30 % more; the makers of most inverters allow up to 1.5 times the rating. Where clipping starts and how to calculate it is in the article on the DC/AC ratio.

Do 720 W panels give more energy per square metre?

Hardly: 10 kW take 43.5 m² with 720 W panels against 43.9 m² with 590 W. The gain is fewer modules, clamps and connections, not area.

The calculation is preliminary. A qualified engineer must check the system before installation.

YieldStructures

News and design tips

What’s new in Solispec, changes to the standards and practical tips on designing solar power systems.

What interests you

How we handle your data: privacy policy.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate