Norms · DBN V.1.2-2:2006
DBN V.1.2-2:2006 “Loads and actions”: what matters for a solar plant
In Ukraine, snow and wind loads on a solar mounting structure are taken from DBN V.1.2-2:2006. This page collects the clauses that a ground frame or a roof mounting actually uses and explains what Changes 1 and 2 brought.
Ground frame designer
Design the ground frame for your solar plant
Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.
- No sign-up
- Snow and wind check
- Drawings and estimate
Edition and status
The 2006 edition with Change 1 (order No. 143 of 13.08.2007, in force from 01.10.2007) and Change 2 (order No. 5 of 16.01.2020, in force from 01.06.2020). Status as of 14.10.2026 per the norms register Solispec checked on 04.10.2026.
The official text: Building norms register, e-construction.gov.ua. Solispec does not host the norm texts. Look for the current edition at the official source.
What Changes 1 and 2 changed
Change 1 (2007) rewrote clause 9.9 — the height factor Ch, Tables 9.01 and 9.02 and the four terrain types I–IV — as well as clause 9.10 (Calt) and 9.13. Change 2 (2020) rewrote clauses 4.17 and 4.18 (combination factors) and 9.16 (edge zone e/10, corners with Caer = −3.5), added clauses 9.17, 9.18 and Annex K, and changed clause 10.1 on icing.
So “DBN loads and actions Change 2” is not a new code but the same 2006 document with both changes. For a solar array Change 1 matters most: the wind pressure at panel height depends on it.
Snow: section 8
S0 is the characteristic snow load, Pa: the weight of snow cover on 1 m² of ground exceeded on average once in 50 years (clause 8.5). The limit design value is formula (8.1), the serviceability value (8.2), and C is a product of three factors (8.4):
Sm = γfm · S0 · C, C = μ · Ce · Caltγfm comes from Table 8.1 by the return period T: 1.00 for 50 years and 1.14 for 100. The shape coefficient μ of a monopitch plane follows scheme 1 of Annex Zh: 1 up to 25°, 0 from 60°, linear between. Ce = 1 when there are no data on the operating regime (clause 8.9). Calt = 1.4H + 0.3 for an altitude H ≥ 0.5 km, otherwise 1 (formula 8.5).
Kyiv example: S0 = 1,550 Pa, panels at 30°, μ = (60 − 30)/35 = 0.857, T = 50 years. Sm = 1.00 · 1,550 · 0.857 ≈ 1,329 Pa on the horizontal projection.
Wind: section 9
W0 is the characteristic wind pressure: the mean component at 10 m height exceeded once in 50 years (clause 9.6). The limit value is formula (9.1), and C is made of six factors (9.3):
Wm = γfm · W0 · C, C = Caer · Ch · Calt · Crel · Cdir · CdCh comes from Table 9.01 by height and terrain type (clause 9.9): I — open sea, lake surfaces and plains without obstacles; II — countryside with fences, small structures and trees; III — suburban and industrial zones, forests; IV — urban areas. When in doubt, take the type with the larger Ch. Calt = 2H for H > 0.5 km (formula 9.4). Annex I has no ready aerodynamic coefficients for panels, and clause 9.8 allows them to be taken from other sources.
Kyiv, panel top at 2 m, terrain II: Ch = 0.7, Wm = 370 · 0.7 = 259 Pa. With an uplift coefficient of 1.8 at 30° the uplift is about 466 Pa.
The city table and icing
The informative annex with the city table gives each city W0, S0, the ice thickness b and the wind pressure with ice WB. Kyiv: 370 Pa, 1,550 Pa, 19 mm, 160 Pa. The snow and wind districts are on the maps (Fig. 8.1, 9.1), but Solispec pages give values in pascals from the table, not a district number.
Under clause 10.1 as amended by Change 2, ice-and-wind loads are taken for overhead communication lines, contact networks, antenna masts and parts of roofs and walls at 150 m and higher. A ground-mounted array is not on that list.
One quirk of the text itself: clause 8.5 refers to “Annex Zh” for S0 and clause 8.7 to “Annex E” for μ. It is the other way round: the city table is in Annex E, the snow schemes in Annex Zh. We do not host a PDF of the code; the official text is in the register linked below.
How Solispec applies it
The Solispec engine takes S0 and W0 of the 22 regional centres from the city table (all 22 match the code), γfm from Tables 8.1 and 9.1 with linear interpolation, and γfe from Tables 8.3 and 9.3 for a time share η = 0.02. The default service life is 50 years, so γfm = 1.00; it can be changed in the constructor.
The engine takes Ch from Table 9.01 by the panel top height and terrain type, Ce = 1, Crel = Cdir = Cd = 1. The pressure coefficients on the panel come from Table 7.6 of EN 1991-1-4:2005, as clause 9.8 allows. The calculation is preliminary: an engineer checks it for design.
Terms
- Characteristic snow load S₀The weight of snow cover per 1 m² of ground exceeded on average once in 50 years; under DBN V.1.2-2:2006 Kyiv has 1,550 Pa.
- Characteristic wind pressure W₀The mean wind pressure at 10 m height exceeded on average once in 50 years; Kyiv has 370 Pa under DBN V.1.2-2:2006.
- Reliability factor for the limit value γfmThe multiplier on S₀ and W₀ that depends on the mean return period T: 1.00 at 50 years, 1.14 at 100 years (Tables 8.1, 9.1).
- Snow shape coefficient μThe conversion from ground snow to roof snow: μ = 1 up to 25°, 0 from 60°, linear in between (DBN V.1.2-2:2006, Annex Zh, scheme 1).
- Height factor ChThe wind correction for height above ground and terrain type, Table 9.01 of DBN V.1.2-2:2006: 0.7 at 5 m and 0.9 at 10 m for type II.
- Terrain type I–IVThe wind classification of a structure’s surroundings under cl. 9.9 of DBN V.1.2-2:2006: from open water (I) to dense urban areas (IV).
- Icing: ice thickness b and wind pressure WBIce-wind load under section 10 of DBN V.1.2-2:2006; Kyiv has b = 19 mm and W_B = 160 Pa, but it is not required for ground PV.
- Snow and wind zonesThe zones of maps Fig. 8.1 and 9.1 of DBN V.1.2-2:2006; for calculations the S₀ and W₀ values in Pa from the city table are easier to use.
Other norms
- DBN V.2.6-198:2014 “Steel structures”: tubes in PV framesHow the Ukrainian steel structures code applies to closed tubes in a ground PV frame: Ry, γm, the buckling factor φ and the checks Solispec runs.
- DSTU-N B EN 1993-1-3:2012: designing C-profiles for PV mountingWhy a perforated 41×41 C-channel is checked to Eurocode 3 rather than DBN V.2.6-198: effective section, γ_M factors, bolts in slots.
- DSTU-N B V.1.1-27:2010: climatic regions and Tmin for PV stringsBuilding climatology for a solar plant: Ukraine’s climatic regions, the minimum temperature and why the string length depends on it.
Solispec’s calculation is preliminary: for a design it has to be checked by an engineer. The values and clauses follow the current editions of the norms on the date of the page.