Glossary · Climate

Climatic region (DSTU-N B V.1.1-27)

A region of Ukraine by building climatology; for PV it gives the absolute minimum air temperature used to check string voltage.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Definition

DSTU-N B V.1.1-27:2010 "Building climatology" divides Ukraine into climatic regions (Table 1 and Figure 1). A PV plant needs one number from it: the absolute minimum air temperature of the site. DSTU HD 60364-7-712:2022 (Annex B) calls it Tmin and puts it into the UOC MAX formula.

RegionNameTmin, °C (in Solispec)
INorth-western−40
IISouth-eastern−42
IIIACarpathian−38
IIIBTranscarpathian−32
IVSouthern coast of Crimea−20
VCrimean mountains−27

For regions I and II, Table 1 gives a range (−37…−40 °C and −32…−42 °C). Solispec takes the colder end: a lower temperature means a higher open-circuit voltage, so the result errs on the safe side. Example: Kyiv lies in region I, so Tmin = −40 °C; Odesa is in region II, Tmin = −42 °C. The I/II boundary was read from Figure 1 by eye, so near the line itself the accuracy is about 0.2–0.3°.

Do not confuse the climatic region with the snow and wind districts of DBN V.1.2-2:2006: these are different maps from different norms, and their boundaries do not coincide.

Where the boundary runs in practice. The north and west of the country, including Kyiv, Zhytomyr, Chernihiv, Rivne and Lutsk, lie in region I. The south and east — Odesa, Mykolaiv, Kherson, Zaporizhzhia, Dnipro, Kharkiv — are in region II, and there the Solispec minimum is even lower, −42 °C, because the cold end of the table range is used. This surprises many people: for the string voltage check, southern Ukraine is not 'warmer' than the north. The Transcarpathian lowland (IIIB, −32 °C) is the notable exception. If your site lies near a region boundary, it is safer to enter Tmin by hand from the colder region: spare voltage margin costs at most one panel per string, while a shortfall can cost an inverter.

How Solispec applies it

The Solispec engine finds the region from the site coordinates (climateRegion): Crimea first, then the Transcarpathian lowland and the Carpathian belt, then the I/II boundary. If you have not set Tmin yourself, the string check uses that region’s minimum and shows the source "DSTU-N B V.1.1-27:2010, Table 1". Your own value always wins. For a project with no site placed on the map no region is assigned, and the 1.2·UOC STC rule applies.

String calculator

Norms and clauses

Related terms

The whole glossary

Solispec’s calculation is preliminary: for a design it has to be checked by an engineer. The values and clauses follow the current editions of the norms on the date of the page.