Section of the table from the Solispec engine (median zone — Cherkasy)

REC

Ground frame for 24 REC Alpha Pro MG REC610AA Pro MG (HJT, bifacial) panels (2×12)

2 rows of 12 panels, 14.64 kW. The Solispec engine chose the profiles, the frame pitch and the footings for three snow and wind zones: Kherson has the lowest load of the regional centres, Cherkasy the median, Chernihiv the highest.

Power
14.64kW
Steel
491.2kg
Posts
16
Bolts
174
Materials
63,715₴
Yield
16,672kWh/year

Figures for the median zone (Cherkasy); all three zones are in the table below.

Ground frame designer

Open this frame in the builder

The builder opens with the REC Alpha Pro MG REC610AA Pro MG (HJT, bifacial) panel and the 2 × 12 layout; site — Cherkasy. Change the site, the tilt or the profiles and the checks and estimate are recalculated.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Three snow and wind zones

The same table designed for three regional centres: with the lowest, the median and the highest combined snow and wind load under DBN V.1.2-2:2006. For another site, open the frame in the builder.

ParameterLow loadKherson · S₀ 760 · W₀ 480Median loadCherkasy · S₀ 1,520 · W₀ 420High loadChernihiv · S₀ 1,720 · W₀ 410
PostsTube 60×60×2Tube 60×60×2Tube 60×60×2
RaftersC-channel 60×40×2Tube 60×60×2C-channel 60×40×2
Purlins and bracesC-channel 60×40×2C-channel 60×40×2C-channel 60×40×2
Frames8 frames, pitch up to 2,190 mm8 frames, pitch up to 2,190 mm10 frames, pitch up to 1,720 mm
Posts161620
Footings (bored concrete)16 pcs, Ø400 mm, depth 1,100 mm16 pcs, Ø350 mm, depth 1,100 mm20 pcs, Ø300 mm, depth 1,300 mm
Concrete2.43 m³1.86 m³2.02 m³
Tilt30°30°30°
Panel bottom / post top600 / 2,138 mm600 / 2,138 mm600 / 2,138 mm
Panel field size16,020 × 2,844 mm16,020 × 2,844 mm16,020 × 2,844 mm
Row spacing between tables (no shade on 21 December)9,810 mm at noon · 11,020 mm ±2 h10,870 mm at noon · 12,550 mm ±2 h11,910 mm at noon · 14,150 mm ±2 h
Steel462.4 kg491.2 kg539.8 kg
BoltsM10 — 122, M8 — 52M10 — 122, M8 — 52M10 — 142, M8 — 52
Panel clampsend 8, middle 44end 8, middle 44end 8, middle 44
Materials64,486 UAH63,715 UAH67,521 UAH
With installation and delivery102,146 UAH101,735 UAH105,006 UAH
Per 1 kW6,977 UAH/kW6,949 UAH/kW7,173 UAH/kW
Yield1,266 kWh/kW · 18,541 kWh/year1,139 kWh/kW · 16,672 kWh/year1,043 kWh/kW · 15,271 kWh/year
Strength σ/fy72%98%65%
Deflection / (L/200)62%84%44%
Rafter strength86%77%99%
Post utilisation17%23%19%
Utilisation97%100%78%
Depth vs frost depthokokok
Checks overallwith a cautionwith a cautionwith a caution

Checks and cautions

Member utilisation as the engine computes it. Cautions are checks that pass, but with a small margin.

  • Rafter profileThe rafter is used above 80 %, or the frame's posts stand far apart: the structure passes, but the margin is small.Kherson: Rafter C-channel 60×40×2: span between posts 2 094, cantilever 758 mm → strength 86%.Chernihiv: Rafter C-channel 60×40×2: span between posts 2 094, cantilever 758 mm → strength 99%.
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Kherson: Foundation Ø400 × 1 100: 0.138 m³ of concrete per post. Wind uplift on the front post ≈ 12.9 kN (with γ=1.5) vs ≈ 13.4 kN (concrete weight + soil friction, estimate) → 97%.Cherkasy: Foundation Ø350 × 1 100: 0.106 m³ of concrete per post. Wind uplift on the front post ≈ 11.3 kN (with γ=1.5) vs ≈ 11.4 kN (concrete weight + soil friction, estimate) → 100%.
  • Max. frame pitch, mmThe purlins between the frames are used above 80 % (strength or deflection): the structure passes, but the margin is small. A shorter frame pitch or a deeper purlin gives more margin.Cherkasy: Frame spacing 2 190 mm, 8 frames. Purlin C-channel 60×40×2: strength 98%, deflection 84% of L/200 (snow on panel 977 Pa).

Bill of materials

The parts of one table for the median zone (Cherkasy): mark, name, profile, cut length, quantity.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,2168
П2Rear postTube 60×60×23,2638
Кр1Rafter (inclined beam)Tube 60×60×23,6108
Пк1Frame strutC-channel 60×40×21,6888
Х1Longitudinal brace (cross)C-channel 60×40×22,6704
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×26,0002
Р4Purlin (rail)C-channel 60×40×26,0002
Р5Purlin (rail)C-channel 60×40×24,0202
Р6Purlin (rail)C-channel 60×40×24,0202
—Bolt M10×140 / M10×80 set · frame and struts / purlins, braces, connectors——106
—Bolt M10×150 set · brace to post, strut to rafter — through spacer inserts——16
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——44
—Bolt M8×50 + channel nut——52
—Concrete for 16 posts, Ø350×1100——1.86 m³

Profile cutting

32 bars of 6,000 mm, 161.0 m of profile in total.

  • Tube 60×60×216 bars
  • C-channel 60×40×216 bars

Estimated cost

The engine's materials estimate for the median zone (Cherkasy).

Materials
63,715₴
With installation and delivery
101,735₴
Per 1 kW
6,949UAH/kW

Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

All 20 lines of the engine's estimate, with prices
ItemQuantityPrice, UAHSum, UAH
Tube 60×60×2, stock length 6 000 mm16 bar21020,160
C-channel 60×40×2, stock length 6 000 mm16 bar23022,080
C-channel connector (splice plate L 300)8 pcs90720
Bolt M10×140 cl. 8.8 set — frame, struts40 pcs22880
Bolt M10×80 cl. 8.8 set — purlins, braces, connectors79 pcs221,738
Bolt M10×150 cl. 8.8 set — strut to rafter, brace to post — through spacer inserts16 pcs27432
End clamp 30 mm8 pcs35280
Mid clamp (30–40 mm)44 pcs321,408
Bolt M8×50 A2 + spring channel nut M858 pcs14812
Post base anchor pin (M10 / rebar Ø12)16 pcs20320
Borehole casing (roofing felt / PVC, 300 mm)16 pcs60960
Crushed stone 20–40 for the bottom of the boreholes0.15 m³900135
Earth electrode: 2 rods Ø16×1.5 m + strip 40×41 set1,5001,500
Wire PV-3 6 mm² green-yellow38 m351,330
Module earthing clip (under the clamp)24 pcs20480
Cable clip, stainless72 pcs5360
Zinc paint / cold galvanising spray 400 ml2 pcs350700
Concrete M200 for posts1.86 m³3,8007,068
Rebar Ø10 (4 bars per post)84 m282,352
Spacer inserts / packs — pieces of the same profile (from offcuts): 4 × 71 mm, 8 × 70 mm, 4 × 30 mm, 8 × 10 mm24 pcs00
Materials63,715

Yield

Yield: 1,139 kWh per 1 kW a year, ≈ 16,672 kWh a year in total (median zone, Cherkasy; tilt 30°, the optimum for the latitude is 35.3°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other layouts of this panel

The 2×12 layout with other panels

Next