Which solar panels to choose: TOPCon, bifacial, power and size
Which solar panels to choose for a home — TOPCon, HJT or back-contact, bifacial or not, what power and size, Voc in frost, warranties. With a checklist.
Which solar panels to choose for a home depends not on the "best technology" but on your roof, the snow and wind in your region and your inverter. For most roofs a modern monocrystalline panel of 430–500 W fits: it is easy to carry, fits a roof slope more easily and needs no reinforced mounting. Large 580–720 W panels and bifacial models pay off on the ground, and before buying any panel check its Voc in frost, its mechanical load rating and the warranties in the datasheet.
Monocrystalline or polycrystalline solar panels
Manufacturers have settled this question themselves. Polycrystalline panels have practically disappeared from new ranges, and our catalogue has none: all 98 models in the panel catalogue are monocrystalline. So today the comparison is not mono versus poly but between monocrystalline cell technologies: PERC, TOPCon, HJT and back-contact.
If you are offered polycrystalline panels as a "cheaper option", it is most likely old warehouse stock. Compare it with current models by the same datasheet values: power per square metre, temperature coefficients, degradation and warranty.
Cell technologies: PERC, TOPCon, HJT and back-contact
The name of a technology guarantees nothing by itself. What matters to a buyer are the datasheet numbers that depend on it.
- PERC — the previous generation, on p-type silicon. There are fewer and fewer such models. They usually show higher first-year degradation and lose more power in heat than the newer n-type ones.
- TOPCon — the most common technology among new panels, n-type silicon. Many TOPCon models are bifacial.
- HJT (heterojunction) — also n-type, cells with thin layers of amorphous silicon. HJT datasheets usually show the smallest temperature coefficients and high bifaciality.
- Back-contact (IBC, ABC, HPBC) — the contacts are moved to the rear of the cell, the front has no busbars. This gives more power per square metre. Bifaciality of such panels is usually lower, and most models are monofacial.
What to compare between technologies:
- Temperature coefficient of power Pmax, %/°C. The closer to zero, the less the panel loses in heat. In summer a cell on a roof easily runs 20–30 °C above the air.
- Temperature coefficient of voltage Voc, %/°C. It sets how much the voltage rises in frost. In our catalogue it ranges from −0.20 to −0.28 %/°C.
- Degradation — in the datasheet or warranty: how much power the panel may lose in the first year and each year after, and what percentage is guaranteed in year 25 or 30.
- Bifaciality (%) — how much the rear side gives relative to the front under the same light. It only matters for bifacial panels.
Bifacial or monofacial solar panels
A bifacial panel also takes light on its rear side: reflected from the ground, snow or a light roof. Our catalogue has 67 bifacial models out of 98, about 68 %. But more is not always better for your site.
When bifacial panels help:
- a ground-mounted plant or a carport with space and light under the panels;
- a bright surface under the panels: snow, gravel, a light flat-roof membrane, sand;
- the height of the lower edge above the ground — the higher, the more evenly light reaches the rear;
- vertical or nearly vertical rows (a fence), where both sides see the sky.
When there is little benefit:
- a pitched roof, where the panel sits 10–15 cm above the covering: the rear is almost in shade, and dark tiles reflect little;
- the rear side is blocked by rails, brackets or neighbouring rows.
A bifacial panel usually has glass on both sides and is heavier. Our catalogue has pairs of 590 W models from one range: the monofacial one weighs 27 kg, the bifacial one 31 kg. On a roof this weight adds to the snow. The "rear-side gain" tables in a datasheet show possible values, not a guarantee: the real gain depends on the surface, height and angle.
One more consequence: the rear side increases current. If you put bifacial panels on the ground, leave a margin on the inverter's maximum input current — this is the fourth check in the article how many panels in a string.
What panel power to choose and solar panel size
A panel's power is almost always its area. Efficiency of current models differs by a few percent, size by a factor of one and a half. In our catalogue power ranges from 400 to 720 W, length from 1722 to 2465 mm, width from 1032 to 1305 mm, frame depth 30–40 mm, weight from 19.7 to 38.7 kg.
Panels up to 500 W (38 such models in the catalogue, 1722–1961 mm long, mostly 1134 mm wide, 19.7–27.7 kg):
- one person can lift and hold one on a roof, though two are safer;
- they are easier to lay out on a small or complex roof slope, around windows, a chimney and the roof edges;
- a smaller area means less wind force per fixing.
Panels of 580–720 W (55 such models in the catalogue, 2175–2465 mm long, 2.58–3.11 m² in area, 26.9–38.7 kg):
- fewer panels, clamps and connections for the same power;
- on the ground and on large flat roofs they save structure;
- but on a roof it is a sail of over 3 m²: carry it only with two people and not in windy weather;
- wind force on a panel is proportional to its area, so the load on fixings and clamps is higher.
Will it fit on the roof. Lay out the rows with the edges in mind: ДБН В.1.2-2 (cl. 9.16) requires increased wind uplift to be calculated in a strip along the roof perimeter and in the corners. A long panel enters this strip more often, so the fixing spacing there is smaller. Details are in the article solar panel roof mounting.
Clamping zones. The manufacturer states in the datasheet on which parts of the frame the panel may be clamped and what load it then withstands. For long panels these zones matter more: rails placed elsewhere may reduce the allowed load and void the warranty.
How many panels your consumption needs is worked out by the calculator what size system a house needs. The whole path from the goal to the grid connection is in the article how to build a home solar plant.
Electrical parameters for the inverter: Voc, frost and current
Before buying panels, check them against the inverter. From the panel datasheet you need:
- Voc — open-circuit voltage at STC. In our catalogue from 36 to 65.7 V. The higher the Voc, the fewer panels fit in a string.
- Temperature coefficient of Voc — in frost the voltage rises. Under ДСТУ HD 60364-7-712 it is calculated for the absolute minimum temperature of the site.
- Vmp — the operating voltage, which must stay within the MPPT range both in heat and in frost.
- Isc and Imp — current; large panels have higher current, and it must fit the input limits.
Example: a panel with Voc 50 V at −30 °C. With a coefficient of −0.25 %/°C the voltage in frost is 50 · (1 + 0.25 · 55 / 100) ≈ 56.9 V, with −0.20 %/°C it is 55.5 V. For a string of 16 panels the difference is already about 22 V, and that can be the difference between "fits" and "exceeds the input maximum".
The four string checks in detail are in the article how many panels in a string. You can work out your own case in the string calculator, and find a panel–inverter pair that works together in the compatibility table.
Warranties and certificates: what to read in the datasheet
A panel usually has two warranties, and they are often confused:
- Product warranty — covers manufacturing defects: delamination, cracks, faulty frame or junction box. Its term is given in years.
- Power warranty — what percentage of rated power the panel will keep after a certain number of years. It is usually given as the first-year loss, the annual loss after that and the remainder at the end of the term.
Read the manufacturer's warranty document itself, not an advertising brochure: it has conditions — installation per the manual, clamping zones, who records a defect and how. Also make sure the warranty is valid in your country and who services it.
Among certificates, look for compliance with IEC 61215 (design qualification: heat, humidity, ultraviolet and mechanical load tests) and IEC 61730 (safety). Check that the certificate covers your exact model and rating, not just the range.
Mechanical load and the snow of your region
A panel datasheet states the mechanical load it withstands on the front (snow, wind pressure) and the rear (wind uplift), in Pa. Manufacturers often give two values: test load and design load. The design load is lower — the test load divided by a safety factor. Compare the design value with the load at your site, and for the mounting method you will actually use.
Snow in Ukraine varies. In the table of oblast centres our engine uses (ДБН В.1.2-2:2006), the characteristic snow load ranges from 760 Pa in Kherson to 1720 Pa in Chernihiv. Reliability factors, altitude and snow drifts near obstacles are added to it, and terrain type to the wind. Work out snow and wind for your address in the snow and wind calculator, then compare with the panel datasheet.
Checklist: which solar panels to choose for a home
- Decide on the location: pitched roof, flat roof or ground. For a slope, monofacial 430–500 W panels are most often simpler; for the ground, large bifacial ones make sense.
- Work out the required system power and the number of panels.
- Lay out the panels on the roof, with edges and obstacles, before choosing a model.
- Compare the Pmax and Voc temperature coefficients, degradation and bifaciality — from the datasheet.
- Check Voc in frost, the MPPT range and current for your inverter.
- Compare the panel's mechanical load rating with the snow and wind at the site.
- Find the clamping zones in the datasheet and make sure the mounting matches them.
- Read both warranties and their conditions, check the IEC 61215 and IEC 61730 certificates for the model.
- Buy all panels of a plant as one model: different panels in one string limit each other.
Frequently asked questions
Which solar panels are better — TOPCon or PERC?
Most new models are already TOPCon, and their datasheets usually show smaller temperature coefficients and lower degradation than PERC. But compare the actual datasheet numbers of two models, not the names of technologies.
Is it worth putting bifacial panels on a roof?
On a pitched roof the gain from the rear side is usually small, because the panel sits close to the covering. A bifacial panel is also heavier. If price and weight are the same there is no harm, but do not count on the gain. On the ground and over a bright surface bifacial panels are justified.
What panel power to choose for a private house?
For a pitched roof 430–500 W panels are most often convenient: they are easier to carry and lay out. Panels of 580–720 W pay off better on the ground and on large flat roofs. In the end it is decided by how many panels fit on your roof without entering the edge zones.
What size is a 450 W and a 600 W solar panel?
In our catalogue 440–460 W panels are 1722–1872 mm long, 1032–1134 mm wide and weigh 20.3–26 kg. Panels of 600–650 W are 2175–2465 mm long, 1134–1305 mm wide and 27.7–36.8 kg. Take the exact size from the datasheet of the specific model.
Can different panels be combined in one plant?
Not in one string: the string current is limited by the weakest panel, and Voc and Vmp must match. Different panels go on different MPPT inputs, and each input is checked separately in the string calculator.
The calculation is preliminary. A qualified engineer must check it before installation.