How to build a home solar power system: from sizing to switch-on
How to build a solar power system yourself: goal, size, tilt, snow and wind, mounting, strings, batteries, cables and payback — with free calculators.
A home solar power system is built in this order: first the goal and the inverter type, then the size for your consumption, the site and tilt, snow and wind loads, mounting, strings, batteries, cables and protection, payback — and only then installation and grid connection. Each step rests on the one before it, so a mistake at the start gets more expensive with every step that follows. Below is the whole path, with a free Solispec calculator for each step.
All the steps on one page
- Goal and inverter type — outages, self-consumption or selling the surplus; grid-tied or hybrid.
- Size — annual consumption and how much 1 kW of panels yields at your address: what solar system a house needs.
- Site, tilt and rows — roof or ground, orientation, tilt angle, row spacing: tilt angle and row spacing.
- Snow and wind — characteristic values per ДБН В.1.2-2 for the site: snow and wind by address.
- Mounting — attachment spacing on a pitched roof, ballast on a flat one, a truss on the ground.
- Inverter and strings — how many panels in series, frost included: strings and inverter.
- Batteries — how many hours the house runs without the grid: how long the batteries last.
- Cables, protection, earthing — per ДСТУ HD 60364-7-712, ПУЕ:2026 and ДБН В.2.5-23:2025.
- Payback — yield, savings, payback period: solar payback.
- Installation — the order of work and safety.
- Grid connection — the distribution system operator's documents and conditions.
What each step needs and what to calculate it with:
| Step | What you need | Solispec tool |
|---|---|---|
| 1. Goal and inverter type | outage pattern, terms for selling the surplus | the article "Grid-tie or hybrid inverter" |
| 2. System size | 12 months of consumption, address, tilt and orientation | solar system size calculator (PVGIS) |
| 3. Site, tilt, rows | latitude, roof or plot dimensions, shade-free window | tilt and row spacing calculator |
| 4. Snow and wind | address, altitude, terrain category | snow and wind calculator per ДБН В.1.2-2 |
| 5. Mounting | roof covering, rafter spacing, loads from step 4 | attachment, ballast and ground truss calculators |
| 6. Inverter and strings | panel and inverter datasheets, minimum temperature | string calculator |
| 7. Batteries | what runs during an outage and for how many hours | battery backup calculator |
| 8. Cables and protection | layout, cable run lengths, inverter type | Solispec designer (checks per ДСТУ HD 60364-7-712) |
| 9. Payback | system cost, tariffs, export terms | payback calculator |
| 10. Installation | the mounting calculation and the layout | PDF project from the designer |
| 11. Grid connection | the distribution system operator's terms | — the documents are set by the operator |
Step 1. The goal and the inverter type
Where to start with a home solar system? With the question of why you want it. The answer decides the inverter type, and the inverter decides everything else.
- Power during outages. You need a hybrid inverter and batteries. The system keeps working when the grid is down.
- Savings on self-consumption. A grid-tied inverter is enough: the panels power the house by day and the grid covers the rest. A grid-tied inverter has no batteries, so it also shuts down in an outage.
- Selling the surplus. The system can be larger than your daytime consumption, because an exported kilowatt-hour is paid for too. Whether you can sell and on what terms — check with your local grid operator and your supplier.
The goal is often twofold: savings and backup. That also means a hybrid, with batteries sized for the hours of autonomy (step 7).
How to make this decision with five questions and a table is covered in grid-tie or hybrid inverter.
Step 2. Consumption and system size
The system size in kW is the annual consumption in kWh divided by how much 1 kW of panels produces a year at your address. The yield depends on the region, the tilt and the orientation. Take consumption from 12 months of bills, not from a single month: winter and summer differ.
An example following our calculator's logic: a house in Kyiv uses 4,000 kWh a year, the roof faces south at 35°. By the design tool's formula, 1 kW of panels here produces about 1,100 kWh a year. The system that covers the whole year's consumption is 7 panels of 550 W, i.e. 3.85 kW. If the surplus is not sold, the calculator suggests a smaller self-consumption option — 4 panels, 2.2 kW: each extra panel must still be at least half used by the house rather than feeding the grid.
A DIY 10 kW solar system is 18–19 panels of 550 W. By the same calculation it produces about 11,000 kWh a year in Kyiv, so it makes sense for a house with electric heating, a heat pump or an electric car. The panels alone of such a system need about 50 m².
The what solar system a house needs calculator uses PVGIS data for your address and falls back to the design tool's formula when PVGIS does not answer. It shows the panel count, the area, the inverter type and the batteries.
A table for typical houses from 2,400 to 9,000 kWh a year, with panel counts and area, is in what size solar system a house needs.
Step 3. The site: roof or ground, tilt and row spacing
A roof needs a cheaper structure, but its angle and orientation are already given. South is best; east and west give less over the year but stretch production into the morning and evening. The ground gives freedom of tilt and orientation but needs a truss, supports and space between rows.
The optimal tilt for annual yield depends on latitude: for Kyiv the design tool's model gives about 36°. Row spacing on the ground or a flat roof is set by the winter sun. The tilt angle and row spacing calculator takes 21 December and computes the shadow of a row's top edge. Example: Kyiv, two panels in portrait up the slope, 35° tilt, shade-free from 10:00 to 14:00 solar time — the row pitch comes out at 15.6 m edge to edge. On a smaller plot you lower the tilt, the number of panels up the slope or the shade-free window — and accept the winter losses knowingly.
Step 4. Snow and wind in your region
The structure is designed for loads, not "like the neighbour's". In Ukraine the basis is ДБН В.1.2-2:2006 (Loads and Actions). For a solar system what matters is snow, wind and the dead weight of the panels and structure.
The snow and wind by address calculator takes the characteristic values of the nearest regional centre (within 200 km) and adjusts them for altitude and terrain category. The terrain changes wind a lot: an open field and a built-up area are different cases. The attachment, ballast and truss calculators then use the same values.
Step 5. Mounting: pitched roof, flat roof or ground
Pitched roof. Attachments go only on rafters, so their spacing is a multiple of the rafter spacing. The attachment spacing on a pitched roof calculator limits the spacing by roof covering and by snow on the panels: above 1.5 kPa of snow, no more than 800 mm. Near the roof edges and corners wind uplift is higher, so the spacing there is shorter. What it looks like for a specific covering — on the metal tile mounting page.
Flat roof. Rows that do not pierce the roof are held by ballast. The flat roof ballast calculator checks uplift and sliding; at the roof edge the wind is multiplied by 1.5, in a corner by 2. The numbers — on the flat roof mounting page.
Ground. You need a truss: beam, posts, brace, supports. The ground truss calculation calculator checks every member: C-profile per ДСТУ-Н Б EN 1993-1-3:2012, tube per ДБН В.2.6-198:2014. What to check before a truss goes to fabrication — in the article how a ground truss is checked. Examples of ground structures — on the ground-mounted system page, other roofs — in mounting by roof type.
Step 6. Inverter and strings, frost included
The inverter's power is chosen for the system and for the house's loads, and the number of panels per string for its MPPT inputs. The main check is frost: a panel's open-circuit voltage rises as it gets colder. Per ДСТУ HD 60364-7-712 (Annex B) it is computed for the site's absolute minimum temperature, and when that or the panel's temperature coefficient is missing — as 1.2 · U_oc.
Example: a panel with U_oc 49.9 V, an inverter with a 500 V input maximum and MPPT 150–425 V. In frost that is 1.2 · 49.9 ≈ 59.9 V per panel, so no more than 8 panels per string. Heat sets the lower limit: the operating voltage must stay within MPPT, so at least 5 panels. The strings and inverter calculator also checks the upper MPPT limit in winter and the input current. The four checks in detail — in the article how many panels per string.
Step 7. Batteries for backup
Usable battery energy = count × capacity × depth of discharge from the datasheet × inverter efficiency (the calculator takes 0.9). Hours of autonomy = usable energy / the power of what must run without the grid.
Example: two batteries of 5.12 kWh with 90 % depth of discharge give about 8.3 kWh of usable energy. A 500 W load — fridge, router, lighting, boiler pump — runs about 16–17 hours on them without recharging from the panels. The inverter must also carry the load, or it shuts down. Work out your own case in the how long the batteries last calculator.
Step 8. Cables, protection and earthing
In Ukraine the electrical requirements are in ПУЕ:2026 and ДБН В.2.5-23:2025, the specifics of PV installations in ДСТУ HD 60364-7-712:2022. What the Solispec design tool checks:
- DC cable — solar H1Z2Z2-K, rated for the heat under the panels (at least 70 °C, 712.523.101). We keep the voltage drop within 1.5 % — our target, not a requirement of the norm.
- gPV fuses — when three or more strings run in parallel on one MPPT input, on both poles of each string (712.431, 712.432).
- DC load-break switch, if the inverter has none built in (712.537.2).
- Surge protection (SPD): on DC — type 2, or type 1+2 with lightning protection (712.534); on AC — at the service entrance and next to the inverter (ДБН В.2.5-23, 8.6).
- AC breaker and a type B RCD, if the inverter has no separation — see the inverter datasheet (712.433.104).
- Equipotential bonding — 6 mm² copper to the main earthing terminal, 16 mm² with lightning protection (ПУЕ:2026, 1.7.149). The system's earthing is shared with the house (ПУЕ:2026, 1.7.59).
Step 9. Payback
Payback is computed from the annual yield, the share of self-consumption and the tariffs. Self-consumption saves at the tariff you pay, exports at the selling price, if you have one; panels lose about 0.5 % of output a year. The solar payback calculator shows the annual yield, savings, payback period and cumulative savings over 25 years. You enter the system cost and tariffs yourself: we do not insert a price we do not know. If you do not sell, set the selling price to 0.
Step 10. How to install solar panels: order and safety
- Check the state of the roof or the ground. For piles, do a test screw-in on the site.
- Install the attachments or the truss as calculated: spacing, bolt count, ballast.
- Lay the rails and the panels. Do not connect the strings to the inverter until the rest of the circuit is ready.
- Run the DC and AC cables, install the protection and do the equipotential bonding.
- Before connecting, measure each string's voltage and check the continuity of the protective conductors.
- Switch the inverter on following the manufacturer's instructions.
Panels produce voltage as soon as light falls on them, and the inverter cannot switch it off. Treat DC circuits as live. Work at height with fall protection. The connection to the panel board and the grid is done by a licensed electrician.
Step 11. Grid connection and paperwork
A system running in parallel with the grid is connected under the distribution system operator's rules. In Ukraine the general requirements are in the Distribution System Code. The list of documents, timelines, the meter and the terms for selling the surplus depend on your local grid operator and the type of system, so check them with the operator before buying equipment. That way you will not buy an inverter you have to replace.
Installers do the whole project — from loads to the PDF and the client quote — in Solispec (for installers).
Common mistakes
- Sizing from one month's bill. Take the year: a winter month oversizes the system, a summer one undersizes it.
- A grid-tied inverter for backup. It shuts down with the grid, and batteries cannot be connected to it.
- Rows spaced by eye. There is no shade in summer, but in winter the front row shades the back one.
- Snow and wind "as in the next region". Take the values for the site and its terrain category.
- Attachments off the rafters. The spacing must be a multiple of the rafter spacing and shorter near the roof edges.
- A string sized from the summer datasheet. Voltage is higher in frost — check for the coldest morning.
- Buying equipment before talking to the grid operator. Connection terms first, then the inverter.
Sources
- ДБН В.1.2-2:2006 "Loads and actions. Design code" (with amendments) — snow, wind, self-weight.
- ДСТУ HD 60364-7-712:2022 — requirements for photovoltaic power supply systems in low-voltage installations (the Ukrainian adoption of HD 60364-7-712).
- ПУЕ:2026 — Ukraine's electrical installation rules: earthing and equipotential bonding.
- ДБН В.2.5-23:2025 — design of electrical equipment of civil buildings, surge protection.
- ДСТУ-Н Б EN 1993-1-3:2012 — cold-formed thin-gauge steel members (Eurocode 3, part 1-3).
- ДБН В.2.6-198:2014 "Steel structures. Design code".
- IEC 62446-1 — grid-connected photovoltaic systems: testing, documentation and maintenance (string commissioning measurements).
- IEC 61215 and IEC 61730 — design qualification and safety of PV modules; IEC 62109-1/-2 — safety of inverters.
- The Distribution Code (NEURC resolution No. 310 of 14.03.2018) — connection to the distribution system operator's grid in Ukraine.
- PVGIS of the European Commission's Joint Research Centre — solar radiation and yield data.
Frequently asked questions
Can I build a solar power system myself?
The structure and the panels — yes, if you have calculated the loads, mounting and strings. The connection to the board and the grid, protection and earthing must be done by a licensed electrician, and a qualified engineer should check the calculation before installation.
How many panels do I need for 10 kW?
18–19 panels of 550 W, or more panels of lower power. In Kyiv on a south roof at 35° such a system produces about 11,000 kWh a year by our design tool's formula.
Grid-tied or hybrid inverter?
Grid-tied — for savings, when outages do not bother you. Hybrid — when you need power without the grid: it works with batteries.
How much space does the system need?
One 550 W panel measures about 2.35 × 1.1 m. On a roof the area is the sum of the panels with the gaps. On the ground the row spacing is added, and it can be several times the depth of the row itself.
Do I need a permit for a home solar system?
It depends on whether the system works with the grid and whether you sell the surplus. Check the procedure and documents with your local grid operator: we do not describe a procedure that the distribution system operator sets.