Solar power plant in Neumünster, Germany: yield, tilt angle and row spacing
Neumünster: 969 kWh per kWp a year at the optimal tilt of 39°, 1° east of south (PVGIS). 7.2% below the median of the main cities of Germany (1,045). #192 of 193 main cities of Germany by yield. For comparison, Kyiv: 1,114 kWh/kWp — 13.0% less here.
Neumünster is in Schleswig-Holstein. Population 80,196 (GeoNames). 24 m above sea level. 29 km away: Kiel, the nearest bigger city, 990 kWh/kWp — 2.0% less here. 18.32 m between rows, pitch 22.04 m, GCR 0.22 (latitude 54.1°).
- Yield of 1 kWp
- 969kWh/year
- Tilt
- 39°1° east of south
- 10 kW
- 9,693kWh/year
- Row pitch
- 22.04m · GCR 0.22
- Rank in the country
- 192of 193 cities
Ground frame designer
A ground frame for a solar plant: Neumünster
Latitude 54.1°: the tilt and the row pitch follow it. Enter the snow and wind for Germany in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
May: 128 kWh/kWp, December: 21 — 6.1 times less.
December: 21 against the median of 30 for the main cities of Germany, 30.0% less.
| kWp | A year | May | December |
|---|---|---|---|
| 5 | 4,847 | 640 | 105 |
| 10 | 9,693 | 1,280 | 210 |
| 15 | 14,540 | 1,920 | 315 |
Snow and wind loads
Snow and wind loads for a site in Germany follow DIN EN 1991-1-3/NA (snow load zone, Schneelastzone) and DIN EN 1991-1-4/NA (wind zone, Windzone). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Germany: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: DIN EN 1991-1-3/NA, DIN EN 1991-1-4/NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.