Section of the table from the Solispec engine (median zone — Cherkasy)

REC

Ground frame for 30 REC Alpha Pure-RX REC470AA Pure-RX (HJT) panels (2×15)

2 rows of 15 panels, 14.10 kW. The Solispec engine chose the profiles, the frame pitch and the footings for three snow and wind zones: Kherson has the lowest load of the regional centres, Cherkasy the median, Chernihiv the highest.

Power
14.10kW
Steel
483.0kg
Posts
18
Bolts
212
Materials
63,303₴
Yield
16,057kWh/year

Figures for the median zone (Cherkasy); all three zones are in the table below.

Ground frame designer

Open this frame in the builder

The builder opens with the REC Alpha Pure-RX REC470AA Pure-RX (HJT) panel and the 2 × 15 layout; site — Cherkasy. Change the site, the tilt or the profiles and the checks and estimate are recalculated.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Three snow and wind zones

The same table designed for three regional centres: with the lowest, the median and the highest combined snow and wind load under DBN V.1.2-2:2006. For another site, open the frame in the builder.

ParameterLow loadKherson · S₀ 760 · W₀ 480Median loadCherkasy · S₀ 1,520 · W₀ 420High loadChernihiv · S₀ 1,720 · W₀ 410
PostsTube 60×60×2Tube 60×60×2Tube 60×60×2
RaftersC-channel 60×40×2C-channel 60×40×2C-channel 60×40×2
Purlins and bracesC-channel 41×41×2.5C-channel 60×40×2C-channel 60×40×2
Frames10 frames, pitch up to 1,990 mm9 frames, pitch up to 2,230 mm9 frames, pitch up to 2,230 mm
Posts201818
Footings (bored concrete)20 pcs, Ø350 mm, depth 900 mm18 pcs, Ø300 mm, depth 1,100 mm18 pcs, Ø300 mm, depth 1,300 mm
Concrete1.91 m³1.54 m³1.82 m³
Tilt30°30°30°
Panel bottom / post top600 / 1,830 mm600 / 1,814 mm600 / 1,814 mm
Panel field size18,495 × 2,273 mm18,495 × 2,282 mm18,495 × 2,282 mm
Row spacing between tables (no shade on 21 December)7,800 mm at noon · 8,770 mm ±2 h8,640 mm at noon · 9,980 mm ±2 h9,470 mm at noon · 11,260 mm ±2 h
Steel497.3 kg483.0 kg495.9 kg
BoltsM10 — 158, M8 — 64M10 — 148, M8 — 64M10 — 148, M8 — 64
Panel clampsend 8, middle 56end 8, middle 56end 8, middle 56
Materials63,759 UAH63,303 UAH64,759 UAH
With installation and delivery99,959 UAH99,585 UAH101,041 UAH
Per 1 kW7,089 UAH/kW7,063 UAH/kW7,166 UAH/kW
Yield1,266 kWh/kW · 17,857 kWh/year1,139 kWh/kW · 16,057 kWh/year1,043 kWh/kW · 14,708 kWh/year
Strength σ/fy82%79%85%
Deflection / (L/200)81%69%74%
Rafter strength50%77%83%
Post utilisation10%16%17%
Utilisation95%91%75%
Depth vs frost depthokokok
Checks overallwith a cautionwith a cautionwith a caution

Checks and cautions

Member utilisation as the engine computes it. Cautions are checks that pass, but with a small margin.

  • Max. frame pitch, mmThe purlins between the frames are used above 80 % (strength or deflection): the structure passes, but the margin is small. A shorter frame pitch or a deeper purlin gives more margin.Kherson: Frame spacing 1 990 mm, 10 frames. Purlin C-channel 41×41×2.5: strength 82%, deflection 81% of L/200 (snow on panel 489 Pa).Chernihiv: Frame spacing 2 230 mm, 9 frames. Purlin C-channel 60×40×2: strength 85%, deflection 74% of L/200 (snow on panel 1 106 Pa).
  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Kherson: Foundation Ø350 × 900: 0.087 m³ of concrete per post. Wind uplift on the front post ≈ 8.8 kN (with γ=1.5) vs ≈ 9.3 kN (concrete weight + soil friction, estimate) → 95%.Cherkasy: Foundation Ø300 × 1 100: 0.078 m³ of concrete per post. Wind uplift on the front post ≈ 8.6 kN (with γ=1.5) vs ≈ 9.5 kN (concrete weight + soil friction, estimate) → 91%.
  • Rafter profileThe rafter is used above 80 %, or the frame's posts stand far apart: the structure passes, but the margin is small.Chernihiv: Rafter C-channel 60×40×2: span between posts 1 691, cantilever 612 mm → strength 83%.

Bill of materials

The parts of one table for the median zone (Cherkasy): mark, name, profile, cut length, quantity.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,0939
П2Rear postTube 60×60×22,9399
Кр1Rafter (inclined beam)C-channel 60×40×22,9169
Пк1Frame strutC-channel 60×40×21,4069
Х1Longitudinal brace (cross)C-channel 60×40×22,5434
Р1Purlin (rail)C-channel 60×40×26,0002
Р2Purlin (rail)C-channel 60×40×26,0002
Р3Purlin (rail)C-channel 60×40×26,0002
Р4Purlin (rail)C-channel 60×40×26,0002
Р5Purlin (rail)C-channel 60×40×26,0002
Р6Purlin (rail)C-channel 60×40×26,0002
Р7Purlin (rail)C-channel 60×40×24952
Р8Purlin (rail)C-channel 60×40×24952
—Bolt M10×25 set · purlins, braces, connectors——50
—Bolt M10×80 set · purlin to rafter——36
—Bolt M10×90 set · strut to post — through spacer inserts——9
—Bolt M10×130 set · post–rafter — through spacer inserts——36
—Bolt M10×140 set · strut to rafter — through spacer inserts——9
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——56
—Bolt M8×50 + channel nut——64
—Concrete for 18 posts, Ø300×1100——1.54 m³

Profile cutting

30 bars of 6,000 mm, 168.3 m of profile in total.

  • Tube 60×60×29 bars
  • C-channel 60×40×221 bars

Estimated cost

The engine's materials estimate for the median zone (Cherkasy).

Materials
63,303₴
With installation and delivery
99,585₴
Per 1 kW
7,063UAH/kW

The engine's estimate has 23 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,139 kWh per 1 kW a year, ≈ 16,057 kWh a year in total (median zone, Cherkasy; tilt 30°, the optimum for the latitude is 35.3°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other layouts of this panel

The 2×15 layout with other panels

Next