Section of the table from the Solispec engine (median zone — Cherkasy)

LONGi

Ground frame for 10 LONGi Hi-MO X10 LR7-54HVH-485M panels (2×5)

2 rows of 5 panels, 4.85 kW. The Solispec engine chose the profiles, the frame pitch and the footings for three snow and wind zones: Kherson has the lowest load of the regional centres, Cherkasy the median, Chernihiv the highest.

Power
4.85kW
Steel
203.9kg
Posts
8
Bolts
74
Materials
27,451₴
Yield
5,523kWh/year

Figures for the median zone (Cherkasy); all three zones are in the table below.

Ground frame designer

Open this frame in the builder

The builder opens with the LONGi Hi-MO X10 LR7-54HVH-485M panel and the 2 × 5 layout; site — Cherkasy. Change the site, the tilt or the profiles and the checks and estimate are recalculated.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Three snow and wind zones

The same table designed for three regional centres: with the lowest, the median and the highest combined snow and wind load under DBN V.1.2-2:2006. For another site, open the frame in the builder.

ParameterLow loadKherson · S₀ 760 · W₀ 480Median loadCherkasy · S₀ 1,520 · W₀ 420High loadChernihiv · S₀ 1,720 · W₀ 410
PostsTube 60×60×2Tube 60×60×2Tube 60×60×2
RaftersC-channel 100×50×2.5C-channel 60×40×2C-channel 60×40×2
Purlins and bracesC-channel 60×40×2C-channel 60×40×2C-channel 60×40×2
Frames4 frames, pitch up to 1,780 mm4 frames, pitch up to 1,780 mm4 frames, pitch up to 1,780 mm
Posts888
Footings (bored concrete)8 pcs, Ø350 mm, depth 1,300 mm8 pcs, Ø300 mm, depth 1,100 mm8 pcs, Ø300 mm, depth 1,300 mm
Concrete1.10 m³0.68 m³0.81 m³
Tilt30°30°30°
Panel bottom / post top600 / 1,848 mm600 / 1,865 mm600 / 1,865 mm
Panel field size5,890 × 2,381 mm5,890 × 2,371 mm5,890 × 2,371 mm
Row spacing between tables (no shade on 21 December)8,120 mm at noon · 9,130 mm ±2 h9,000 mm at noon · 10,400 mm ±2 h9,870 mm at noon · 11,720 mm ±2 h
Steel224.6 kg203.9 kg209.6 kg
BoltsM10 — 50, M8 — 24M10 — 50, M8 — 24M10 — 50, M8 — 24
Panel clampsend 8, middle 16end 8, middle 16end 8, middle 16
Materials35,593 UAH27,451 UAH28,113 UAH
With installation and delivery48,948 UAH40,806 UAH41,468 UAH
Per 1 kW10,092 UAH/kW8,414 UAH/kW8,550 UAH/kW
Yield1,266 kWh/kW · 6,142 kWh/year1,139 kWh/kW · 5,523 kWh/year1,043 kWh/kW · 5,059 kWh/year
Strength σ/fy38%53%57%
Deflection / (L/200)27%37%40%
Rafter strength17%66%71%
Post utilisation10%13%14%
Utilisation62%77%63%
Depth vs frost depthokokok
Checks overallpassespassespasses

Checks and cautions

Member utilisation as the engine computes it. Cautions are checks that pass, but with a small margin.

No cautions.

Bill of materials

The parts of one table for the median zone (Cherkasy): mark, name, profile, cut length, quantity.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,1144
П2Rear postTube 60×60×22,9904
Кр1Rafter (inclined beam)C-channel 60×40×23,0204
Пк1Frame strutC-channel 60×40×21,4504
Х1Longitudinal brace (cross)C-channel 60×40×22,1774
Р1Purlin (rail)C-channel 60×40×25,8904
—Bolt M10×25 set · purlins, braces, connectors——2
—Bolt M10×80 set · purlin to rafter——16
—Bolt M10×90 set · strut to post — through spacer inserts——4
—Bolt M10×130 set · post–rafter — through spacer inserts——16
—Bolt M10×140 set · strut to rafter — through spacer inserts——4
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——16
—Bolt M8×50 + channel nut——24
—Concrete for 8 posts, Ø300×1100——0.68 m³

Profile cutting

13 bars of 6,000 mm, 70.6 m of profile in total.

  • Tube 60×60×24 bars
  • C-channel 60×40×29 bars

Estimated cost

The engine's materials estimate for the median zone (Cherkasy).

Materials
27,451₴
With installation and delivery
40,806₴
Per 1 kW
8,414UAH/kW

The engine's estimate has 22 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,139 kWh per 1 kW a year, ≈ 5,523 kWh a year in total (median zone, Cherkasy; tilt 30°, the optimum for the latitude is 35.3°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other layouts of this panel

The 2×5 layout with other panels