Section of the table from the Solispec engine (median zone — Cherkasy)

Jinko

Ground frame for 10 Jinko Tiger Neo JKM485N-60HL4-V panels (2×5)

2 rows of 5 panels, 4.85 kW. The Solispec engine chose the profiles, the frame pitch and the footings for three snow and wind zones: Kherson has the lowest load of the regional centres, Cherkasy the median, Chernihiv the highest.

Power
4.85kW
Steel
208.4kg
Posts
8
Bolts
74
Materials
28,831₴
Yield
5,523kWh/year

Figures for the median zone (Cherkasy); all three zones are in the table below.

Ground frame designer

Open this frame in the builder

The builder opens with the Jinko Tiger Neo JKM485N-60HL4-V panel and the 2 × 5 layout; site — Cherkasy. Change the site, the tilt or the profiles and the checks and estimate are recalculated.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Three snow and wind zones

The same table designed for three regional centres: with the lowest, the median and the highest combined snow and wind load under DBN V.1.2-2:2006. For another site, open the frame in the builder.

ParameterLow loadKherson · S₀ 760 · W₀ 480Median loadCherkasy · S₀ 1,520 · W₀ 420High loadChernihiv · S₀ 1,720 · W₀ 410
PostsTube 60×60×2Tube 60×60×2Tube 60×60×2
RaftersC-channel 100×50×2.5C-channel 60×40×2C-channel 60×40×2
Purlins and bracesC-channel 60×40×2C-channel 60×40×2C-channel 60×40×2
Frames4 frames, pitch up to 1,780 mm4 frames, pitch up to 1,780 mm4 frames, pitch up to 1,780 mm
Posts888
Footings (bored concrete)8 pcs, Ø350 mm, depth 1,300 mm8 pcs, Ø300 mm, depth 1,100 mm8 pcs, Ø300 mm, depth 1,300 mm
Concrete1.10 m³0.68 m³0.81 m³
Tilt30°30°30°
Panel bottom / post top600 / 1,926 mm600 / 1,943 mm600 / 1,943 mm
Panel field size5,890 × 2,516 mm5,890 × 2,506 mm5,890 × 2,506 mm
Row spacing between tables (no shade on 21 December)8,600 mm at noon · 9,670 mm ±2 h9,530 mm at noon · 11,010 mm ±2 h10,440 mm at noon · 12,410 mm ±2 h
Steel230.0 kg208.4 kg214.1 kg
BoltsM10 — 50, M8 — 24M10 — 50, M8 — 24M10 — 50, M8 — 24
Panel clampsend 8, middle 16end 8, middle 16end 8, middle 16
Materials35,593 UAH28,831 UAH29,493 UAH
With installation and delivery48,948 UAH42,186 UAH42,848 UAH
Per 1 kW10,092 UAH/kW8,698 UAH/kW8,835 UAH/kW
Yield1,266 kWh/kW · 6,142 kWh/year1,139 kWh/kW · 5,523 kWh/year1,043 kWh/kW · 5,059 kWh/year
Strength σ/fy41%56%60%
Deflection / (L/200)29%39%42%
Rafter strength19%74%80%
Post utilisation11%15%16%
Utilisation66%82%68%
Depth vs frost depthokokok
Checks overallpasseswith a cautionpasses

Checks and cautions

Member utilisation as the engine computes it. Cautions are checks that pass, but with a small margin.

  • Embedment, mmThe footing resists wind uplift at above 80 % utilisation, or it is shallower than the frost depth. The soil resistance in the calculation is an estimate — check the soil on site.Cherkasy: Foundation Ø300 × 1 100: 0.078 m³ of concrete per post. Wind uplift on the front post ≈ 7.8 kN (with γ=1.5) vs ≈ 9.5 kN (concrete weight + soil friction, estimate) → 82%.

Bill of materials

The parts of one table for the median zone (Cherkasy): mark, name, profile, cut length, quantity.

MarkPartProfileLength, mmQuantity
П1Front postTube 60×60×22,1424
П2Rear postTube 60×60×23,0684
Кр1Rafter (inclined beam)C-channel 60×40×23,1924
Пк1Frame strutC-channel 60×40×21,5184
Х1Longitudinal brace (cross)C-channel 60×40×22,2214
Р1Purlin (rail)C-channel 60×40×25,8904
—Bolt M10×25 set · purlins, braces, connectors——2
—Bolt M10×80 set · purlin to rafter——16
—Bolt M10×90 set · strut to post — through spacer inserts——4
—Bolt M10×130 set · post–rafter — through spacer inserts——16
—Bolt M10×140 set · strut to rafter — through spacer inserts——4
—Bolt M10×150 set · brace to post — through spacer inserts——8
—End clamp 30 mm——8
—Mid clamp (30–40 mm)——16
—Bolt M8×50 + channel nut——24
—Concrete for 8 posts, Ø300×1100——0.68 m³

Profile cutting

14 bars of 6,000 mm, 72.1 m of profile in total.

  • Tube 60×60×24 bars
  • C-channel 60×40×210 bars

Estimated cost

The engine's materials estimate for the median zone (Cherkasy).

Materials
28,831₴
With installation and delivery
42,186₴
Per 1 kW
8,698UAH/kW

The engine's estimate has 22 lines; the full list is in the builder. Prices are the typical market prices built into the Solispec engine, as of 06.10.2026; no margin, no VAT.

Yield

Yield: 1,139 kWh per 1 kW a year, ≈ 5,523 kWh a year in total (median zone, Cherkasy; tilt 30°, the optimum for the latitude is 35.3°).

A preliminary calculation; a design needs an engineer's check. Snow and wind per DBN V.1.2-2:2006 for the regional centre; profiles, footings and estimate by the Solispec engine 0.12.0.

Other layouts of this panel

The 2×5 layout with other panels

Next