Poland: solar plant site data
Solar power plant in Biała Podlaska, Poland: yield, tilt angle and row spacing
Biała Podlaska: 1,057 kWh per kWp a year at the optimal tilt of 39°, 4° east of south (PVGIS). 0.7% below the median of the main cities of Poland (1,065). #61 of 87 main cities of Poland by yield. For comparison, Kyiv: 1,114 kWh/kWp — 5.1% less here.
Biała Podlaska is in Lublin Voivodeship. Population 57,541 (GeoNames). 142 m above sea level. 58 km away: Siedlce, the nearest bigger city, the same 1,058 kWh/kWp. 14.97 m between rows, pitch 18.69 m, GCR 0.26 (latitude 52.0°).
- Yield of 1 kWp
- 1,057kWh/year
- Tilt
- 39°4° east of south
- 10 kW
- 10,573kWh/year
- Row pitch
- 18.69m · GCR 0.26
- Rank in the country
- 61of 87 cities
Ground frame designer
A ground frame for a solar plant: Biała Podlaska
Latitude 52.0°: the tilt and the row pitch follow it. Enter the snow and wind for Poland in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 133 kWh/kWp, December: 26 — 5.1 times less.
December: 26 against the median of 32 for the main cities of Poland, 18.8% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,287 | 665 | 130 |
| 10 | 10,573 | 1,330 | 260 |
| 15 | 15,860 | 1,995 | 390 |
Snow and wind loads
Snow and wind loads for a site in Poland follow PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) with the Polish National Annex (NA). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Poland: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: PN-EN 1991-1-3 + NA, PN-EN 1991-1-4 + NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.