Solar plant: site data

Solar power plant in Viktorivka, Mykolaivskyi Raion, Mykolaiv Oblast

Viktorivka: 1,285 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 7.3% above the oblast median (1,198). #22 of 238 in the rayon, #22 of 909 in the oblast.

Mykolayiv, the rayon centre, is 56 km away. 5 m above sea level. 22 km away: Berezanka, the nearest bigger centre, 1,260 — 2.0% more here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 56 km. 9.57 m between rows, pitch 13.39 m (latitude 46.7°).

Yield of 1 kWp
1,285kWh/year
Tilt
37°1° east of south
10 kW
12,850kWh/year
Row pitch
13.39m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Viktorivka

The designer opens with this place’s coordinates, latitude 46.7° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 56 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

49Jan66Feb109Mar131Apr147May146Jun156Jul154Aug130Sep101Oct55Nov41Dec

July: 156 kWh/kWp, December: 41 — 3.8 times less.

January: 49 against 38 in the oblast, 28.9% more.

Viktorivka: plants, kWh
kWpA yearJulyDecember
56,425780205
1012,8501,560410
1519,2752,340615

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.