Solar plant: site data

Solar power plant in Elevatorne, Mykolaivskyi Raion, Mykolaiv Oblast

Elevatorne: 1,269 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 5.9% above the oblast median (1,198). #41 of 238 in the rayon, #41 of 909 in the oblast.

Mykolayiv, the rayon centre, is 48 km away. 9 m above sea level. 13 km away: Berezanka, the nearest bigger centre, 1,260 — 0.7% more here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 48 km. 9.63 m between rows, pitch 13.45 m (latitude 46.7°).

Yield of 1 kWp
1,269kWh/year
Tilt
37°1° east of south
10 kW
12,687kWh/year
Row pitch
13.45m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Elevatorne

The designer opens with this place’s coordinates, latitude 46.7° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 48 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

46Jan64Feb108Mar130Apr145May145Jun154Jul152Aug129Sep101Oct55Nov40Dec

July: 154 kWh/kWp, December: 40 — 3.9 times less.

December: 40 against 33 in the oblast, 21.2% more.

Elevatorne: plants, kWh
kWpA yearJulyDecember
56,344770200
1012,6871,540400
1519,0312,310600

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.