Solar plant: site data
Solar power plant in Andriyivka, Mykolaivskyi Raion, Mykolaiv Oblast
Andriyivka: 1,221 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). 2.0% above the oblast median (1,198). #198 of 238 in the rayon, #260 of 909 in the oblast.
Mykolayiv, the rayon centre, is 45 km away. 3 m above sea level. 5 km away: Nova Odesa, the nearest bigger centre, 1,212 — 0.7% more here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 45 km. 9.76 m between rows, pitch 13.63 m (latitude 47.3°).
- Yield of 1 kWp
- 1,221kWh/year
- Tilt
- 36°3° east of south
- 10 kW
- 12,213kWh/year
- Row pitch
- 13.63m · GCR 0.35
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 870 / 470Pa
Ground frame designer
A ground frame for a solar plant: Andriyivka
The designer opens with this place’s coordinates, latitude 47.3° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 45 km: snow 870 Pa, wind 470 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 152 kWh/kWp, December: 35 — 4.3 times less.
January: 42 against 38 in the oblast, 10.5% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 6,107 | 760 | 175 |
| 10 | 12,213 | 1,520 | 350 |
| 15 | 18,320 | 2,280 | 525 |
Example: a 10 kW ground frame
For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.
How these numbers are computed
Nearby
- Troyitske3 km1,221 kWh/kWp
- Sukha Balka4 km1,230 kWh/kWp
- Yasna Polyana4 km1,220 kWh/kWp
- Nova Odesa5 km1,212 kWh/kWp
- Novoandriyivka6 km1,220 kWh/kWp
- Mykhaylivka6 km1,216 kWh/kWp
All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.