Solar plant: site data

Solar power plant in Mykhaylivka, Mykolaivskyi Raion, Mykolaiv Oblast

Mykhaylivka: 1,216 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.5% above the oblast median (1,198). #208 of 238 in the rayon, #289 of 909 in the oblast.

Mykolayiv, the rayon centre, is 50 km away. 22 m above sea level. 11 km away: Nova Odesa, the nearest bigger centre, the same 1,212. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 51 km. 9.78 m between rows, pitch 13.65 m (latitude 47.4°).

Yield of 1 kWp
1,216kWh/year
Tilt
36°2° east of south
10 kW
12,157kWh/year
Row pitch
13.65m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Mykhaylivka

The designer opens with this place’s coordinates, latitude 47.4° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 51 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

41Jan59Feb104Mar124Apr140May141Jun152Jul149Aug125Sep97Oct50Nov36Dec

July: 152 kWh/kWp, December: 36 — 4.2 times less.

February: 59 against 54 in the oblast, 9.3% more.

Mykhaylivka: plants, kWh
kWpA yearJulyDecember
56,079760180
1012,1571,520360
1518,2362,280540

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.