Germany: solar plant site data
Solar power plant in Freiburg im Breisgau, Germany: yield, tilt angle and row spacing
Freiburg im Breisgau: 1,120 kWh per kWp a year at the optimal tilt of 38°, 1° east of south (PVGIS). 7.3% above the median of the main cities of Germany (1,045). #22 of 193 main cities of Germany by yield. For comparison, Kyiv: 1,114 kWh/kWp — 0.6% more here.
Freiburg im Breisgau is in Baden-Württemberg. Population 237,460 (GeoNames). 278 m above sea level. 120 km away: Karlsruhe, the nearest bigger city, 1,135 kWh/kWp — 1.3% less here. 10.69 m between rows, pitch 14.46 m, GCR 0.33 (latitude 48.0°).
- Yield of 1 kWp
- 1,120kWh/year
- Tilt
- 38°1° east of south
- 10 kW
- 11,204kWh/year
- Row pitch
- 14.46m · GCR 0.33
- Rank in the country
- 22of 193 cities
Ground frame designer
A ground frame for a solar plant: Freiburg im Breisgau
Latitude 48.0°: the tilt and the row pitch follow it. Enter the snow and wind for Germany in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 129 kWh/kWp, December: 45 — 2.9 times less.
December: 45 against the median of 30 for the main cities of Germany, 50.0% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,602 | 645 | 225 |
| 10 | 11,204 | 1,290 | 450 |
| 15 | 16,806 | 1,935 | 675 |
Snow and wind loads
Snow and wind loads for a site in Germany follow DIN EN 1991-1-3/NA (snow load zone, Schneelastzone) and DIN EN 1991-1-4/NA (wind zone, Windzone). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Germany: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: DIN EN 1991-1-3/NA, DIN EN 1991-1-4/NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.