Engineering method

Engineering method: what Solispec computes, by which standards, and how

Solispec is a calculation tool for structures that carry solar panels. This page describes, from the engine code, how loads and checks follow from an address and a layout, what the engine does not compute, and who is responsible for the result.

In the browser, nothing to install, no card: the Start plan is free.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

What this page is, and what the result is

This page describes how the Solispec calculation engine turns an address, a panel layout and a choice of profiles into loads, member and fixing checks, ballast and footing conditions, and a report. Every rule below is taken from the engine code, not from a marketing description. What is not listed here, the engine does not compute.

The result is preliminary. It is not a stamped design and not a signed calculation. A qualified engineer who knows the site, the soil or the roof, and the local rules must check it before installation. Every page of the report says the same.

From the address to design loads

The engine first finds the characteristic snow and wind values, then turns them into design values.

Snow and wind coefficients as implemented

For a canopy, that is a ground table or a ballasted truss, these coefficients are used.

Load combinations and factors

What the calculation implements. The ψ0 values and the others are taken from the tables of the standards named.

ItemUkraine (DBN V.1.2-2)Abroad (EN 1990, national annex values)
Permanent load, unfavourable1.05 (metal, Table 5.1; equipment, Table 6.1)1.35
Permanent load, favourable (ballast, uplift)0.91.0
Snow or wind as the leading actionLimit value with γfm (1.0 at a 50-year life), factor 1.01.5 (EN 1990, Table A1.2(B))
The second variable actionFactor 0.9 (clause 4.18 of DBN), both ordersψ0: wind 0.6, snow 0.5 (0.7 above 1 000 m)
Deflection (serviceability)Serviceability values of Tables 8.3 and 9.3 (η = 0.02) against L/200The characteristic combination G + S + ψ0·W against L/200
Partial factors of steel resistanceγM0 = 1.0, γM1 = 1.0, γM2 = 1.25: the EN recommended values, no national annex appliedPoland 1.0 / 1.0, Germany 1.0 / 1.1, Spain 1.05 / 1.05 (γM0 / γM1 of the national annexes), other countries: the recommended values

Checked November 9, 2026

Steel: members and deflection

Every member is checked for the forces of the worst combination.

Bolts, nodes and the rule of one hole, one bolt

The nodes of the frame are bolted, and every bolt is chosen, placed and checked.

Ballast, piles, footings and the load on a roof

The supports are checked for uplift, sliding and the capacity of what they stand on.

What Solispec does not calculate

Stated plainly, so that it is clear what is left to the engineer:

How it is tested and versioned

The calculation engine is a separate package with its own automated tests: more than 1 600 tests in more than 90 files, all passing on 9 November 2026 (engine version 0.14.0). The tests pin the results for fixed projects, check the no-clash rule for many configurations, and compare loads and ballast with a hand calculation from the formulas of the standards.

Three worked examples where the engine’s figures match a hand calculation are on the page “Worked check”. A test recomputes their numbers, so the page cannot drift from the product.

Who is responsible, and independent review

Solispec is built by a solar installer and engineer from Ukraine. The Solispec results are preliminary, and the tool does not sign them. The engineer who checks and signs the final design is responsible for it. Solispec supports the work and does not replace the professional’s responsibility.

Independent engineering review of the calculation engine: planned. It has not happened yet. Found an error or a case the tool gets wrong? Write to [email protected] and include the project link.

Where to go next

Questions

Which standards does Solispec apply?

In Ukraine DBN V.1.2-2:2006 with Changes No. 1 and No. 2 for snow and wind. Abroad EN 1990, EN 1991-1-3 and EN 1991-1-4 with national annex values. For steel EN 1993-1-3 and EN 1993-1-1.

Does anyone sign the Solispec results?

No. The result is preliminary, and a qualified engineer must check it before installation. An independent engineering review of the engine itself is planned.

Are seismic actions and soil covered?

No. Seismic actions are not computed. The soil is taken from an assumption or from a value you enter, and it has to be confirmed by a test or a soil investigation.

Can I see what Solispec produces?

Yes. The samples page has a PDF report of a real calculation, with no prices, marked as a preliminary calculation.

How can I check that the calculation is right?

Compare it with a hand calculation: three worked examples, whose numbers a test checks, are on the page “Worked check”. The final check for a real site is made by an engineer.