Engineering method
Engineering method: what Solispec computes, by which standards, and how
Solispec is a calculation tool for structures that carry solar panels. This page describes, from the engine code, how loads and checks follow from an address and a layout, what the engine does not compute, and who is responsible for the result.
In the browser, nothing to install, no card: the Start plan is free.
Ground frame designer
Design the ground frame for your solar plant
Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.
What this page is, and what the result is
This page describes how the Solispec calculation engine turns an address, a panel layout and a choice of profiles into loads, member and fixing checks, ballast and footing conditions, and a report. Every rule below is taken from the engine code, not from a marketing description. What is not listed here, the engine does not compute.
The result is preliminary. It is not a stamped design and not a signed calculation. A qualified engineer who knows the site, the soil or the roof, and the local rules must check it before installation. Every page of the report says the same.
From the address to design loads
The engine first finds the characteristic snow and wind values, then turns them into design values.
- Ukraine: the address gives the oblast and its regional centre, which supplies the characteristic snow load S0 and the basic wind pressure W0 of DBN V.1.2-2:2006 with Changes No. 1 and No. 2. For Kyiv these are 1 550 Pa and 370 Pa.
- Poland, Germany, Spain: the engine suggests the national annex values s_k and q_b of the nearest main city, at the height of the site. The user confirms or replaces them. In any other country the user enters both values.
- Altitude: in Ukraine the altitude corrections apply from 500 m (formulas 8.5 and 9.4 of DBN), below that there is none. Abroad the annex values are already taken at the height of the site.
- The terrain type I-IV and the height of the installation above the ground affect the wind. On EN 1991-1-4 coefficients (the canopy of Table 7.6, the reference c_p of the fixings) the wind takes the exposure factor c_e(z) = (1 + 7·I_v)·c_r(z)² of EN 1991-1-4, 4.5, with c_o = 1 and k_l = 1, and z_0 and z_min from Table 4.1 for the category: those coefficients are defined on the peak pressure. In Ukraine this is W₀·c_e(z)·Calt with the DBN γfm (W₀, the mean 50-year pressure at 10 m of clause 9.6, is taken as the basic pressure q_b); DBN’s own coefficients (clause 9.16, Annex I) multiply W₀ with the height coefficient C_h of Table 9.01, interpolated linearly between its rows. Abroad c_e(z) acts on the national annex q_b.
- The service life defaults to 50 years, and then the γfm factors of snow and wind from Tables 8.1 and 9.1 of DBN equal 1.0. The consequence factor γn defaults to 1.0 for a private plant and 1.1 for the roof of an apartment or public building (DBN V.1.2-14:2018). The user can change it. It is never applied to stabilising actions such as ballast.
Snow and wind coefficients as implemented
For a canopy, that is a ground table or a ballasted truss, these coefficients are used.
- Snow on a sloping surface: in Ukraine Annex Zh of DBN, scheme 1: μ = 1 up to 25°, 0 from 60°, linear between, Ce = 1 by clause 8.9. Abroad EN 1991-1-3, Table 5.2: μ1 = 0.8 up to 30°, then linear to 0 at 60°. For an array on the ground (angle 0) μ = 1.
- Wind on a canopy: the c_f coefficients of EN 1991-1-4 Table 7.6 for a monopitch canopy at φ = 0, interpolated linearly by angle. For uplift they grow from 0.5 at 0° to 1.8 at 30°, for downward pressure from 0.2 to 1.2. DBN has no such coefficients for the uplift of a canopy of panels, so the reference data of the EN are used, as clause 9.8 of DBN allows.
- Above 30° the table ends: the coefficient is extrapolated, and the report warns to check it against the manufacturer’s data or a wind-tunnel test.
- The wind resultant on a canopy acts at a quarter of its depth from the windward edge (EN 1991-1-4, 7.3(6), Figure 7.16). That decides which share of the uplift the rear support takes.
- Pitched roof: the fixings take a local uplift with a coefficient of 2.0 in a strip e/10 wide along the roof edge and 3.5 in the corners (clause 9.16 of DBN, on W₀·C_h), and a reference value on W₀·c_e(z) elsewhere; in Ukraine the larger of the two uplifts governs. Abroad these values are kept, but never below c_pe,1 of Tables 7.2-7.4 of EN 1991-1-4.
Load combinations and factors
What the calculation implements. The ψ0 values and the others are taken from the tables of the standards named.
| Item | Ukraine (DBN V.1.2-2) | Abroad (EN 1990, national annex values) |
|---|---|---|
| Permanent load, unfavourable | 1.05 (metal, Table 5.1; equipment, Table 6.1) | 1.35 |
| Permanent load, favourable (ballast, uplift) | 0.9 | 1.0 |
| Snow or wind as the leading action | Limit value with γfm (1.0 at a 50-year life), factor 1.0 | 1.5 (EN 1990, Table A1.2(B)) |
| The second variable action | Factor 0.9 (clause 4.18 of DBN), both orders | ψ0: wind 0.6, snow 0.5 (0.7 above 1 000 m) |
| Deflection (serviceability) | Serviceability values of Tables 8.3 and 9.3 (η = 0.02) against L/200 | The characteristic combination G + S + ψ0·W against L/200 |
| Partial factors of steel resistance | γM0 = 1.0, γM1 = 1.0, γM2 = 1.25: the EN recommended values, no national annex applied | Poland 1.0 / 1.0, Germany 1.0 / 1.1, Spain 1.05 / 1.05 (γM0 / γM1 of the national annexes), other countries: the recommended values |
Checked November 9, 2026
Steel: members and deflection
Every member is checked for the forces of the worst combination.
- Cold-formed C profiles and rails: EN 1993-1-3 with the effective widths of EN 1993-1-5, 4.4, the reduction for distortional buckling and buckling curve b (α = 0.34) of EN 1993-1-1, 6.3. Tension with bending, compression with bending, and stability (flexural and lateral-torsional) are checked. Such profiles are outside DBN V.2.6-198, so even in Ukraine they are checked by EN 1993-1-3.
- Tubes: EN 1993-1-1 abroad and DBN V.2.6-198 in Ukraine.
- The partial factors are in the table above. The national annex of EN 1993-1-3 is not applied in Ukraine: the recommended EN values are used, and the report marks them as such.
- Rails and purlins: a continuous beam, M = q·L²/8 (which covers snow on half the span). Truss and frame members: a frame analysis with pinned nodes and one roller support, the forces going into the member checks.
- Deflection: serviceability values against L/200. The limit L/200 is an assumption of the tool, not a requirement of a standard for your project.
- The component along the slope on a rail is not checked.
Bolts, nodes and the rule of one hole, one bolt
The nodes of the frame are bolted, and every bolt is chosen, placed and checked.
- M10 bolts of class 8.8. The length is the first stock length of the 20-200 mm range that is at least 1.1 × (clamped stack + 17.5 mm for washers, spring washer, nut and thread protrusion).
- In the built-in perforated C trusses every bolt goes through a factory slot of every member it joins. Nothing is drilled. If a bolt cannot land in a slot, the design is flagged, and the optimiser looks for the nearest angle at which it does.
- One hole, one bolt: no profile passes through another or through a support, and one hole never holds two bolts. A clash search in the model checks it, and tests pin the rule for many configurations.
- A rafter splice on a multi-row table: the bolt group (elastic distribution V/n plus the moment) against F_v,Rd of the M10 8.8 bolt, 0.6·f_ub·A_s/γM2 with γM2 = 1.25, and against the bearing resistance of EN 1993-1-3, Table 8.4. The lap eccentricity, the torsion of the C and the axial force are not modelled, so a splice is always marked for an engineer to check.
- Table 8.4 of EN 1993-1-3 covers round holes, not slots. So the bearing capacity of a node in a perforation slot has to come from the profile maker’s data or a test, and the numbers of the table stay informative.
Ballast, piles, footings and the load on a roof
The supports are checked for uplift, sliding and the capacity of what they stand on.
- Ballast: uplift and sliding. The wind resultant acts at a quarter of the canopy depth, so the rear support takes the larger share of the uplift plus the overturning of the horizontal component. The weight of ballast takes the factor 0.9 in Ukraine and 1.0 abroad, and γn is not applied to it.
- Screw piles and concrete footings: the uplift per post is compared with the pull-out capacity. The soil capacity is entered by the user, and without data an assumption is used (500 kg per pile in the sample report) that has to be confirmed by a trial pull-out test. The tool does not replace a soil investigation.
- Frost depth: a guide taken from the practice of the country (Ukraine by oblast, Poland by the zones of the map PN-81/B-03020, Germany at least 0.8 m, Spain 0.8 m), below which the post embedment is set. It is not a geotechnical report.
- A flat roof: the load of the array (steel, panels, ballast over the footprint of the supports) with the factors is compared with the allowed load of the roof, which the user takes from a survey or a design. The roof itself is not calculated.
- A multi-row ground table with middle posts: the rafter as a continuous beam (the three-moment equation), a middle post in compression from the support reaction.
What Solispec does not calculate
Stated plainly, so that it is clear what is left to the engineer:
- The structure the array stands on: roof rafters, trusses, purlins, the roof slab. The tool compares the load with the allowance you enter.
- Soil without data: bearing capacity, settlement, heave. A separate soil investigation is needed.
- Seismic actions, fatigue and corrosion.
- Eccentricities and torsion in splices, and the local strength of the panel and its clamps: take the panel load limits from its datasheet.
- A maker’s tested system and its statics approval. Where they are needed, use the maker’s own configurator.
- The quality and tolerances of the installation on site.
How it is tested and versioned
The calculation engine is a separate package with its own automated tests: more than 1 600 tests in more than 90 files, all passing on 9 November 2026 (engine version 0.14.0). The tests pin the results for fixed projects, check the no-clash rule for many configurations, and compare loads and ballast with a hand calculation from the formulas of the standards.
Three worked examples where the engine’s figures match a hand calculation are on the page “Worked check”. A test recomputes their numbers, so the page cannot drift from the product.
- Every report prints the engine version, the norms pack and a calculation id (calc_id), so a result can be tied to the rules it was made with.
- The standards each value comes from, and their versions, are named on the norms pages and in the tables above.
- The tests show that the code does what is described, not that a standard is applied correctly to your site. That needs an engineer’s check.
Who is responsible, and independent review
Solispec is built by a solar installer and engineer from Ukraine. The Solispec results are preliminary, and the tool does not sign them. The engineer who checks and signs the final design is responsible for it. Solispec supports the work and does not replace the professional’s responsibility.
Independent engineering review of the calculation engine: planned. It has not happened yet. Found an error or a case the tool gets wrong? Write to [email protected] and include the project link.
Where to go next
Questions
Which standards does Solispec apply?
In Ukraine DBN V.1.2-2:2006 with Changes No. 1 and No. 2 for snow and wind. Abroad EN 1990, EN 1991-1-3 and EN 1991-1-4 with national annex values. For steel EN 1993-1-3 and EN 1993-1-1.
Does anyone sign the Solispec results?
No. The result is preliminary, and a qualified engineer must check it before installation. An independent engineering review of the engine itself is planned.
Are seismic actions and soil covered?
No. Seismic actions are not computed. The soil is taken from an assumption or from a value you enter, and it has to be confirmed by a test or a soil investigation.
Can I see what Solispec produces?
Yes. The samples page has a PDF report of a real calculation, with no prices, marked as a preliminary calculation.
How can I check that the calculation is right?
Compare it with a hand calculation: three worked examples, whose numbers a test checks, are on the page “Worked check”. The final check for a real site is made by an engineer.