Worked check, 2026
Worked check: Solispec against a hand calculation, step by step
Three cases from three countries, each done twice: by hand from the formulas and tables of the standard, and by the Solispec engine with the same inputs. The inputs, the clause of each step and both results are in the tables. The results are preliminary and an engineer must verify them.
In the browser, nothing to install, no card: the Start plan is free.
Ground frame designer
Design the ground frame for your solar plant
Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.
What was checked, and how to read the tables
Each table has four columns: the step, the formula with the clause it comes from, the result of the hand calculation, and the result Solispec gives for the same input. The hand calculation uses only the formulas and tables of the standards and a calculator; it does not call the Solispec code. The rounding is stated above each table, and the figures agree at that rounding.
This is a check of the arithmetic and of the chain of coefficients that Solispec applies. It is not a third-party validation and it does not replace the engineer who verifies the design for the site. Where Solispec simplifies a standard, the case says so. The page is tested: an automated test recomputes every number on it from the engine, so the build fails if the engine changes and the page does not.
Case 1: Ukraine, Kyiv, a ground frame
A ground-mounted table in Kyiv, with loads by DBN V.1.2-2:2006 with Changes No. 1 and No. 2. The panel coefficients are the engine’s own: the canopy values of EN 1991-1-4 Table 7.6, which clause 9.8 of the DBN allows where its annexes have none for a PV canopy. Those coefficients are defined on the peak pressure, so the wind on them takes the exposure factor c_e(z) of EN 1991-1-4 4.5 instead of C_h of Table 9.01, and W₀ (the mean pressure, clause 9.6) is taken as the basic pressure q_b. The inputs:
- Site: Kyiv, altitude 150 m, terrain category II.
- Tilt of the panels 30 degrees; the upper edge of the panels is 1.51 m above the ground.
- Service life 50 years, so the load factor for the return period is 1.00 (Tables 8.1 and 9.1); altitude factor 1.00 below 500 m.
- Snow is given per square metre of horizontal projection, wind as a pressure on the plane of the panels.
Kyiv, ground frame at 30 degrees: snow and wind
Rounded to 1 Pa; the pressures on the panel plane to 0.1 Pa.
| Step | Formula and clause | Hand result | Solispec |
|---|---|---|---|
| Characteristic snow load S0 | DBN V.1.2-2 table of regions, Kyiv | 1550 Pa | 1550 Pa |
| Snow shape coefficient μ | Annex Zh, scheme 1: μ = (60 − α) / 35 for 25° < α < 60°, so (60 − 30) / 35 | 0.857 | 0.857 |
| Design snow load S | S = γfm · S0 · Calt · μ = 1.00 · 1550 · 1.00 · 0.857 (clauses 8.2 and 8.5, Table 8.1) | 1329 Pa | 1329 Pa |
| Characteristic wind pressure W0 | DBN V.1.2-2 table of regions, Kyiv | 370 Pa | 370 Pa |
| Exposure factor c_e(z) | EN 1991-1-4 4.5, category II (terrain type II), z = 1.51 m is below z_min = 2 m, so c_e(2 m) = (1 + 7/ln 40)·(0.19·ln 40)² | 1.423 | 1.423 |
| Design wind pressure Wm | Wm = γfm · W0 · c_e(z) · Calt = 1.00 · 370 · 1.4234 · 1.00 (clause 9.1, Table 9.1; the EN 1991-1-4 coefficients are defined on the peak pressure, DBN 9.8) | 527 Pa | 527 Pa |
| Wind uplift on the panel plane | EN 1991-1-4 Table 7.6, canopy at 30°: cf = 1.8 upward, so 526.7 · 1.8 | 948.0 Pa | 948.0 Pa |
| Wind pressure down on the panel plane | the same table: cf = 1.2 downward, so 526.7 · 1.2 | 632.0 Pa | 632.0 Pa |
Checked November 6, 2026
Case 2: Poland, Krakow, a flat roof with ballast
A row of five panels on the flat roof of a 6 m building in Krakow. Snow and wind are the values of the Polish national annex at the city; the loads are combined by EN 1990 with the factor 1.5 on wind and 0.9 on the weight that holds the row down. The ballast is checked for uplift and for sliding. The inputs:
- Site: Krakow, altitude 219 m, snow zone 3 and wind zone 1 of the annex, terrain category II, building height 6 m.
- One row of 5 panels of 2350 × 1100 mm (area 12.925 m²), panel weight 12 kg per m², tilt 10 degrees, on one layer of ballast blocks; the upper edge of the row is 0.65 m above the roof, so the wind is taken at 6.65 m.
- Middle roof zone (zone factor 1.0), reliability factor of the building 1.0.
- PVC or TPO membrane with a rubber mat: design friction coefficient 0.40, the tool’s value for that surface.
- The row is treated as an isolated monopitch canopy with an open back: no shelter from other rows and no credit for deflectors.
Krakow, flat roof, 5 panels at 10 degrees: loads and ballast
Rounded to 1 kg, 1 N and 1 Pa; coefficients to three decimals.
| Step | Formula and clause | Hand result | Solispec |
|---|---|---|---|
| Characteristic snow load s_k | PN-EN 1991-1-3 national annex, zone 3: s_k = max(1.2; 0.006 · A − 0.6) at A = 219 m | 1.200 kN/m², 1200 Pa | 1200 Pa |
| Basic wind pressure q_b | PN-EN 1991-1-4 national annex, zone 1, A ≤ 300 m: v_b,0 = 22 m/s, q_b = 0.30 kN/m² (Table NA.1) | 300 Pa | 300 Pa |
| Design snow load | EN 1990 factor 1.5, EN 1991-1-3 Table 5.2: μ1 = 0.8 up to 30°, so 1.5 · 1200 · 0.8 | 1440 Pa | 1440 Pa |
| Exposure factor c_e at 6.65 m | EN 1991-1-4 4.5, category II: z0 = 0.05 m, k_r = 0.19, c_e = (1 + 7 / ln(z / z0)) · (k_r · ln(z / z0))² | 2.099 | 2.099 |
| Design wind pressure Wm | 1.5 · 300 · 2.099 | 945 Pa | 945 Pa |
| Wind force on the row | F = Wm · cf · kz · A · γn, with cf = 0.9 uplift at 10° (EN 1991-1-4 Table 7.6): 944.5 · 0.9 · 1.0 · 12.925 · 1.0 | 10987 N | 10987 N |
| Components of the force | Fz = F · cos 10°, Fx = F · sin 10° | Fz 10820 N, Fx 1908 N | Fz 10820 N, Fx 1908 N |
| Ballast against uplift | (Fz − 0.9 · G · g) / (0.9 · g), with G = 12.925 · 12 = 155.1 kg | 1070 kg | 1070 kg |
| Ballast against sliding | (Fx / μ + Fz) / (0.9 · g) − G, with μ = 0.40 | 1611 kg | 1611 kg |
| Ballast the row needs | the larger of the two; sliding governs here | 1611 kg | 1611 kg |
| Uplift at the most loaded support | resultant d/4 from the windward edge (EN 1991-1-4 7.3(6), Figure 7.16): share 0.836 on the rear line; 1070 / 6 frames · 0.836 | 149 kg per frame | 149 kg per frame |
Checked November 6, 2026
Case 3: Germany, Munich, a ground frame
A ground-mounted table in Munich: the snow and wind values of the German national annex at the city, combined by EN 1990 with the factor 1.5, on the panel plane at 30 degrees. The inputs:
- Site: Munich, altitude 524 m, snow zone 1a and wind zone 2 of the annex, terrain category II.
- Tilt 30 degrees; the upper edge of the panels is 1.51 m above the ground.
- Where Solispec simplifies: the exposure factor is the EN 1991-1-4 category II one with its minimum height of 2 m, not the mixed inland profile of the German annex; the annex values are rounded up to the next 10 Pa.
Munich, ground frame at 30 degrees: snow and wind
Rounded to 1 Pa; the pressures on the panel plane to 0.1 Pa.
| Step | Formula and clause | Hand result | Solispec |
|---|---|---|---|
| Characteristic snow load s_k | DIN EN 1991-1-3/NA, zone 1a = 1.25 × zone 1; zone 1: s_k = 0.19 + 0.91 · ((A + 140) / 760)² = 0.885 at A = 524 m; 1.25 · 0.885 | 1.106 kN/m², 1110 Pa | 1110 Pa |
| Basic wind pressure q_b | DIN EN 1991-1-4/NA, zone 2: q_b = 0.39 kN/m², no altitude factor below 800 m | 390 Pa | 390 Pa |
| Design snow load | EN 1990 factor 1.5, EN 1991-1-3 Table 5.2: μ1 = 0.8 up to 30°, so 1.5 · 1110 · 0.8 | 1332 Pa | 1332 Pa |
| Exposure factor c_e | EN 1991-1-4 4.5, category II; z = 1.51 m is below the minimum 2 m, so z = 2 m: (1 + 7 / ln(2 / 0.05)) · (0.19 · ln(2 / 0.05))² | 1.423 | 1.423 |
| Design wind pressure Wm | 1.5 · 390 · 1.423 | 832.7 Pa | 832.7 Pa |
| Wind on the panel plane | EN 1991-1-4 Table 7.6 at 30°: cf = 1.8 uplift, 1.2 down; 832.7 · 1.8 and 832.7 · 1.2 | 1498.9 Pa up, 999.2 Pa down | 1498.9 Pa up, 999.2 Pa down |
Checked November 6, 2026
What the check does not prove
Agreement with a hand calculation shows that Solispec applies the formulas, tables and factors it states, and applies them correctly. It does not show more than that:
- It is not a validation by a third party. The hand calculation is ours, made from the published standards.
- The annex values are taken at the nearest main city. A site in another snow or wind zone, or at another altitude, needs its own values, which the user enters.
- A maker’s own configurator may allow less ballast for its system, because it can rely on a wind-tunnel report with a shelter factor for rows behind rows. Solispec has no such factor and treats every row as isolated, which leads to more ballast, not less.
- Every result is preliminary. A qualified engineer verifies the design for the actual site, roof or soil, and the local building rules.
Where to go next
Questions
Has Solispec been tested for accuracy by an independent party?
Not by a third party, and we do not claim it. What we publish instead is this check: three cases recomputed by hand from the standards, with the inputs, the clauses and both results, and an automated test that recomputes every number here from the engine. Repeat them in the free calculators, and have an engineer verify any real project.
Can I repeat these numbers myself?
Yes. Enter the inputs listed above each table in the snow and wind calculator and the ballast calculator, with the annex values of the city where the country needs them. The calculators run the same engine as the designer, so the results match the tables.
Which standards do the loads follow?
Ukraine: DBN V.1.2-2:2006 with Changes No. 1 and No. 2. Poland, Germany and Spain: the snow and wind values of the national annex at the nearest main city, combined by EN 1990 with the factor 1.5 on snow and wind, with the canopy coefficients of EN 1991-1-3 and EN 1991-1-4. The methodology page lists the rest.
Why can a maker’s configurator give less ballast?
A maker can use a wind-tunnel report for its own system, which allows a shelter factor for rows behind rows and for deflectors. EN 1991-1-4 gives no such reduction, and Solispec does not model it, so each row is an isolated canopy. Check the maker’s approval if you rely on its system.
Does a matching result mean the design is approved?
No. It shows that the arithmetic and the coefficients are applied as stated. The result is preliminary; a qualified engineer must verify it for the site, the roof or the soil, and the local rules.