Methodology and accuracy: what Solispec computes and by which standards
Solispec is a calculation tool for solar frames and plants. This page states what it computes, by which standards, from which inputs and with which assumptions, and what it does not do. Every result is preliminary.
In the browser, nothing to install, no card: the Start plan is free.
Ground frame designer
Design the ground frame for your solar plant
Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.
What the result is, and what it is not
Solispec turns a site, a layout and a choice of profiles into design loads, member and fixing checks, a bill of materials, drawings and a report. It is meant to take an installer from the address to a defensible estimate fast.
It is not a stamped structural design. Every result is preliminary and must be verified by a qualified engineer who knows the site, the soil or the roof, and the local building rules. The disclaimer page says the same.
Loads and standards
The loads follow the country of the site. Combinations and partial factors depend on it:
- Ukraine: DBN V.1.2-2:2006 with Changes No. 1 and No. 2 for snow and wind, with the region found from the address.
- Poland, Germany, Spain: the characteristic snow load and basic wind pressure of the national annex (PN-EN 1991 with its annex, DIN EN 1991-1-3/NA and -1-4/NA, CTE DB SE-AE) at the nearest main city, offered as a guide the user confirms.
- Combinations abroad: EN 1990 with the factors 1.5 on snow and wind, 1.35 on unfavourable and 1.0 on favourable permanent load, and the accompanying-action factors of the annex tables.
- Snow on a canopy by EN 1991-1-3 (shape coefficient 0.8 up to 30 degrees, falling to 0 at 60); wind on a canopy by the coefficients of EN 1991-1-4 Table 7.6, with the exposure factor of the terrain category.
- Any other country: the user enters the characteristic snow load and the basic wind pressure.
Member, fixing and foundation checks
From the loads the engine checks the parts that are built:
- Steel C profiles and rails by EN 1993-1-3 with the effective-width rules of EN 1993-1-5 and the buckling curves of EN 1993-1-1; tubes by EN 1993-1-1 abroad and ДБН В.2.6-198 in Ukraine.
- The rail as a continuous beam over the supports, the truss members by a frame analysis, deflection against a limit that is an assumption of the tool.
- Bolts at nodes, M10 through factory slots, with the length chosen from the clamped stack.
- Ballast against uplift and sliding, with the resultant of the wind placed as EN 1991-1-4 7.3(6) prescribes.
- Post embedment below a frost depth taken from the country’s practice (a guide), and the load a flat roof must carry against its stated allowance.
Inputs, assumptions and limits
The result is only as good as the inputs: the site and its terrain category, the building height, the profile and panel data, the roof or soil capacity you enter. Check each one.
Known limits, stated plainly:
- The national annex of EN 1993-1-3 is not applied; the recommended partial factors of the EN are used and marked as such.
- The annex values for Poland, Germany and Spain are taken at the nearest main city. A site in the mountains or at a different height than that city needs the exact zone value from the authority.
- Seismic, fatigue, corrosion, soil investigation and roof structure are not computed. Frost depth is a guide, not a geotechnical report.
- Yield uses PVGIS by month and an hourly balance; shading is simplified. It is not an hourly module simulation like PVsyst.
- A maker’s tested system and its statics approval are outside the tool. Use the maker’s own configurator where that approval is required.
Who builds it and how to reach us
Solispec is built by a solar installer and engineer from Ukraine. The engine has automated tests, and the standards it follows, with their versions, are listed on the norms pages.
Found an error or a case the tool gets wrong? Write to [email protected] and include the project link.
Where to go next
Questions
Are the results certified?
No. They are preliminary calculations, not a certified design or a statics proof. A qualified engineer must verify them.
Which standards does Solispec follow?
DBN V.1.2-2 for loads in Ukraine; EN 1990, EN 1991-1-3 and EN 1991-1-4 with national annex values abroad; EN 1993-1-3 and EN 1993-1-1 for steel; string voltage checks by DSTU HD 60364-7-712.
How are snow and wind found for my site?
From the address: by region in Ukraine, and for Poland, Germany and Spain from the nearest main city’s annex zones. You can overwrite the values with the exact ones from your authority.
What happens in a country that is not listed?
You enter the characteristic snow load and the basic wind pressure yourself, and the engine applies the Eurocode combinations and the panel coefficients to them.
Who is responsible for the final design?
The engineer who signs it. Solispec supports the work and does not replace the professional’s responsibility.