Comparison
Solispec, an Excel calculation and manufacturer configurators: what to use, and when
Three ways to check a structure for solar panels: your own Excel sheet, a mounting maker’s tool and Solispec. Below is what each does, honestly, and where each is the best choice. About Solispec only what its code does.
In the browser, nothing to install, no card: the Start plan is free.
Ground frame designer
Design the ground frame for your solar plant
Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.
Three tools, three different jobs
An Excel sheet gives full freedom: you write the formulas, choose the standards and lay out the result. That is flexible, but every formula, reference and unit is yours to verify, and the sheet will not find a mistake in a cell for you.
A mounting maker’s configurator (for example K2 Base or fischer SOLARPANEL-FIX) designs the maker’s own system. According to the makers’ public pages, it issues a report and a parts list for their components. Solispec builds a structure from the profiles and panels you choose and goes on to a bill of materials, drawings and a PDF report.
The comparison by capability
The configurator column holds only what the makers’ public pages state (the sources and the date of the check are on the configurators page). The Solispec column holds only what the code does. Where the makers’ pages are silent, that is not a no.
| Question | Excel sheet | Manufacturer configurator | Solispec |
|---|---|---|---|
| Who defines the structure | You, cell by cell | The maker: its own mounting system and components | You: profiles from the Solispec catalogue and a panel of any size |
| Which structures | Those you built the sheet for | Roof systems; ground tables are mostly not stated on the pages checked | Ground tables, ballasted trusses, flat and pitched roofs |
| Snow and wind | You look the values up and key them in | From the site location, according to the makers | From the address: Ukraine by region, Poland, Germany, Spain by the nearest main city as a guide, elsewhere you enter them |
| Strength checks | Only those you wrote and verified yourself | For the maker’s components; a report, according to the makers | Steel by EN 1993-1-3 and EN 1993-1-1, bolts, ballast, uplift, deflection; the result as a utilisation percentage |
| Bill of materials and drawings | You build them | A parts list and a plan for the maker’s system, according to the makers | Bill of materials, drawings and cutting list from the same model |
| PDF report | You lay it out | A report, according to the makers | A PDF report with the engine version and a calculation id, marked preliminary; a sample is on the samples page |
| A maker’s approval or warranty | None | Possible for its own system, according to the makers; ask the maker | None: the result is preliminary and an engineer checks it |
| Repeatability of the result | Depends on the discipline of your file | Not stated on the pages checked | The engine version and calc_id in every report, more than 1 600 automated tests |
Checked November 2, 2026
When each tool fits
None of the three is best for everything:
- Excel fits when you already have a sheet you trust for a standard case and you answer for every formula.
- A maker’s configurator fits a roof on that maker’s system, when its statics approval or warranty is needed.
- Solispec fits when no maker dictates the system: a ground table, a frame of your own profiles, ballast, and when you want the bill of materials, drawings and PDF from the same data.
- Many installers use two or three: a configurator for a standard roof, Solispec for the rest, Excel for their own checks.
What Solispec does not replace
Solispec does not replace an engineer and carries no maker’s approval:
- The result is preliminary, and a qualified engineer must check it before installation.
- It does not compute the roof structure, soil without data, or seismic actions.
- An independent engineering review of the engine is planned and has not happened yet.
- The rules the engine follows are described in full on the engineering method page.
Where to go next
Questions
Can Solispec replace an Excel calculation?
For the checks it covers, yes: it is faster, and the same inputs always give the same result. Unusual nodes and the roof structure you still check separately.
Do I still need a maker’s configurator if I have Solispec?
If the roof is on a maker’s system and its statics approval or warranty is needed, yes. Solispec gives no such approval.
Is Solispec more accurate than the configurators?
We do not compare accuracy: we do not know the makers’ internal models. Each tool checks its own set of components or profiles under its own assumptions.
Can I see what Solispec produces?
Yes. The samples page has a PDF report of a real calculation, with no prices, marked as a preliminary calculation.
Is Solispec free?
There is a free Start plan with the checks and basic drawings. See the pricing page for the paid plans.