Limit design wind load Wm
The wind load used for strength checks: W_m = γ_fm · W₀ · C, where C covers aerodynamics, height, topography and dynamics.
Ground frame designer
Design the ground frame for your solar plant
Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.
- No sign-up
- Snow and wind check
- Drawings and estimate
Definition
Clause 9.4 of DBN V.1.2-2:2006 gives the limit design wind load as the product of W₀, the reliability factor γfm and the factor C. Clause 9.7 splits C into six multipliers:
Wm = γfm · W0 · C, C = Caer · Ch · Calt · Crel · Cdir · Cd- Caer — the aerodynamic coefficient (cl. 9.8);
- Ch — the height factor (cl. 9.9);
- Calt — the altitude factor (cl. 9.10);
- Crel — topography; equals 1 unless the site is on a hill or slope (cl. 9.11);
- Cdir — direction; normally 1 (cl. 9.12);
- Cd — dynamic factor; 1 for structures with a natural period up to 0.25 s (cl. 9.13).
Example: Kyiv, ground table
W₀ = 370 Pa, a 50-year term (γfm = 1.00), array top at 2 m, terrain type II (Ch = 0.7), altitude below 0.5 km (Calt = 1). Pressure before the aerodynamic coefficient: 370 · 0.7 = 259 Pa. For a panel at 30°, Table 7.6 of EN 1991-1-4:2005 gives cf = −1.8 for uplift and +1.2 downwards, that is 466 Pa up and 311 Pa down.
The serviceability value We = γfe · W₀ · C (formula 9.2), with γfe = 0.21 at η = 0.02, is used for deflections.
How Solispec applies it
Solispec computes Wm = γfm · W₀ · Ch · Calt at the array top, takes Crel = Cdir = Cd = 1 and multiplies the result by the panel cf for the chosen tilt. The resulting uplift and downward forces feed the ballast, rail and truss checks.
Norms and clauses
- DBN V.1.2-2:2006, cl. 9.4–9.13, formulae (9.1)–(9.3)
- EN 1991-1-4:2005, Table 7.6
Related terms
- Characteristic wind pressure W₀The mean wind pressure at 10 m height exceeded on average once in 50 years; Kyiv has 370 Pa under DBN V.1.2-2:2006.
- Height factor ChThe wind correction for height above ground and terrain type, Table 9.01 of DBN V.1.2-2:2006: 0.7 at 5 m and 0.9 at 10 m for type II.
- Aerodynamic coefficient Caer (cf)The multiplier turning wind pressure into force on a shape; for panels Solispec takes c_f from Table 7.6 of EN 1991-1-4:2005, as cl. 9.8 of the DBN allows.
- Terrain type I–IVThe wind classification of a structure’s surroundings under cl. 9.9 of DBN V.1.2-2:2006: from open water (I) to dense urban areas (IV).
- Reliability factor for the limit value γfmThe multiplier on S₀ and W₀ that depends on the mean return period T: 1.00 at 50 years, 1.14 at 100 years (Tables 8.1, 9.1).
- Wind uplift and slidingThe two checks of a ballasted table: wind must neither lift the structure nor slide it across the ground or roof.
- DBN V.1.2-2:2006 “Loads and actions”: what matters for a solar plantNorms explained
Solispec’s calculation is preliminary: for a design it has to be checked by an engineer. The values and clauses follow the current editions of the norms on the date of the page.