Battery backup calculator: how long will a home battery run your house

Choose the battery, how many, the inverter and the power of what must run without the grid — the calculator shows the hours of autonomy.

Updated:

A 10 kWh battery gives the house about 8.10 kWh: capacity × 0.9 (depth of discharge) × 0.9 (inverter efficiency). A gas boiler with pump, a fridge and a router together (an assumption of 230 W) run 35.2 hours on it, and 17.6 hours on 5 kWh. Enter your own battery, inverter and load below.

How the calculator works

The calculator takes the battery from the catalogue, multiplies its rated capacity by the number of modules and applies two losses. The first is the depth of discharge (DoD), the share of the rated capacity the maker lets you use; for the example battery it is 90 %. The second is the efficiency of the inverter, 0.9 in the calculator, because the inverter turns direct current into alternating current and loses part of the energy on the way.

Usable energy = modules × rated kWh × DoD × inverter efficiency. Backup time in hours = usable energy in watt-hours ÷ the load in watts. Going the other way, the rated capacity you need = load × hours ÷ (DoD × efficiency), which is how the answer above gets 4.9 kWh for 4 kWh of energy.

The inverter has to carry the load as well. If the load in watts is above the rated power of the inverter, the inverter shuts down and the result shows no hours, whatever the battery holds. The example inverter is rated at 5 kW.

No solar recharge is counted. The result is the worst case, a night or an overcast day with the grid down. For a day-by-day balance with panels and a load profile use the system size calculator.

Step by step

  1. Choose the battery. Pick the model from the catalogue so its rated kWh and depth of discharge are used.
  2. Enter the number of modules. Type how many modules of that battery you plan to connect.
  3. Choose the inverter. Its rated power is the limit on the load that can run at once.
  4. Enter the load. Add up in watts only what must run at the same time in an outage: fridge, lights, router, a boiler pump.
  5. Read the hours. The result gives the rated and usable energy, the backup time and whether the inverter carries the load.

Assumptions and limits

  • The inverter efficiency is a fixed assumption of 0.9. A real inverter is a little better or worse depending on the load, so treat the hours as an estimate, not a promise.
  • The depth of discharge comes from the catalogue entry of the battery. Check it against the current datasheet before you buy.
  • The load is constant. A fridge cycles, a kettle and an oven add short peaks, and a start-up current of a pump can be several times its running power.
  • A battery that is old or cold gives less than its nameplate. The calculator uses the new, room-temperature figure.
  • No panels are counted and the grid is assumed to be down for the whole time.

Worked example

Example: a house in Kyiv loses power for 8 hours and the essentials draw 500 W together. The energy is 500 × 8 ÷ 1000 = 4 kWh. With a depth of discharge of 90 % and an inverter efficiency of 0.9, the rated capacity must be 4 ÷ (0.9 × 0.9) = 4.9 kWh.

One 5.12 kWh module gives 4.1 kWh usable, which runs 500 W for 8.3 hours. Two modules give 16.6 hours. Without the two losses the same module would seem to last 10.2 hours, which is why a plain kWh ÷ kW sum overstates the result. At twice the load, 1 000 W, the same hours need 2 modules, 10.24 kWh rated.

The example inverter is rated at 5 kW, so it carries 500 W and even 1 000 W. If the load were above its rating, the calculator would show no hours at all.

Reference table

Backup time in hours by number of battery modules and load, example battery and inverter
Modules250 W500 W1 000 W2 000 W
116.68.34.12.1
233.216.68.34.1
349.824.912.46.2
466.433.216.68.3

Hours = modules × rated kWh × depth of discharge × inverter efficiency ÷ load. The hours double with the modules and halve with the load.

How long does a 5, 10 or 15 kWh battery last?

Usable energy = rated capacity × 0.9 (depth of discharge) × 0.9 (inverter efficiency): 4.05, 8.10 and 12.15 kWh. Hours = usable energy ÷ load. The watts in the table are assumptions for the example, averages over the appliance cycles: replace them with the figures from your nameplates. A fridge and a pump draw several times more at start-up, so the inverter must carry the peak.

Hours of typical loads on a 5, 10 and 15 kWh battery, the watts are assumptions
Load (assumption)Power, W5 kWh10 kWh15 kWh
Router and laptop5081.0162.0243.0
LED lights6067.5135.0202.5
Fridge (cycle average)8050.6101.3151.9
Gas boiler with circulation pump10040.581.0121.5
Boiler, fridge and router together23017.635.252.8
The same plus lights29014.027.941.9

Hours = rated capacity × 0.9 × 0.9 ÷ load. Dividing without the two losses overstates the result by about a fifth.

What battery capacity do I need for 8, 12 or 24 hours without power?

The rated capacity needed = load × hours ÷ (0.9 × 0.9). First work out in watts what stays on the backed-up circuit, then calculate.

Rated battery capacity in kWh for 8, 12 and 24 hours by load
Load, W8 h12 h24 h
2902.864.308.59
5004.947.4114.81
1 0009.8814.8129.63
2 00019.7529.6359.26

Rated capacity = W × hours ÷ 1000 ÷ (0.9 × 0.9).

Do solar panels work when the grid is down?

Not on their own: a grid-tied inverter without a battery shuts down with the grid (anti-islanding protection), so panels without a battery do not power the house in a blackout.

With a hybrid inverter and a battery the panels keep working by day, feed the backed-up load and charge the battery, and at night the battery carries the load. The calculator leaves the recharge out on purpose: its result is the worst case, a night or an overcast day.

What to check with an engineer

  • The real load: the start-up currents of pumps and compressors, and which circuits the hybrid inverter backs up.
  • The battery datasheet: the depth of discharge, the continuous discharge power and the behaviour in the cold.
  • The inverter’s backup output rating and how fast it switches over when the grid fails.
  • The wiring of the backed-up circuits, the protection devices and the rules of your country for a connected generator or battery.
  • The warranty terms of the battery, which often limit the cycles a year.

How this calculator differs from other battery calculators

  • Many online battery calculators multiply watts by hours and stop. This one also applies the depth of discharge of the battery model you pick and an inverter efficiency of 0.9, so the capacity it asks for is the rated capacity printed on a datasheet.
  • It checks that the inverter can carry the load. An overloaded inverter shuts down, so the result then shows no hours.
  • It takes the battery from a catalogue of real models and counts the modules, instead of leaving you to convert kWh into products.
  • It assumes no solar recharge, so the result is the worst case: a night or an overcast day. For a day-by-day balance use the system size calculator.
  • It is free, needs no sign-up, and the inputs are kept in the link, so you can send the exact calculation.

The calculation is preliminary. A qualified engineer must check it before installation. Codes: DBN V.1.2-2:2006 (Ukraine) and the Eurocode; for other countries — snow and wind values from the national annex, entered by hand.

Frequently asked questions

How long does a 10 kWh battery last?

At the assumed 230 W (boiler with pump, fridge, router) it is 35.2 hours, at 500 W about 16.2 hours. The usable energy of 8.10 kWh is divided by the load. The inverter must also carry the load: in the example it is rated at 5 kW.

How do I calculate the battery capacity for 8 hours of backup?

Multiply the load in kW by the hours to get the usable energy: here 500 W × 8 h = 4 kWh. Divide by the depth of discharge and the inverter efficiency to get the rated capacity: 4 / (0.9 × 0.9) = 4.9 kWh.

Is there a free online calculator for solar battery backup time?

Yes. This page is free and needs no account. Choose the battery, how many, the inverter and the load, and it shows the usable energy, the hours and whether the inverter carries the load.

Why not use the full rated capacity of the battery?

Makers allow only a share of the capacity to be used, the depth of discharge (90 % for the example battery), and the inverter loses part of the energy (0.9 is assumed). The full rating would overstate the hours.

Does the result include recharging from the panels?

No. The result is the worst case with no sun. By day the panels extend the backup time, but by how much depends on the season and the weather.

What load should I enter?

Add up only what must run at the same time during an outage, such as the fridge, lights, router and a boiler pump. The inverter rating (5 kW in the example) is the upper limit.

How long will a home battery run a house?

It depends on the load. The usable energy is 4.1 kWh after the depth of discharge and the inverter losses, so at 500 W it runs about 8.3 hours and at 1 000 W about half of that. Divide the usable energy by the watts you actually draw.

How many batteries do I need for a power cut?

Work out the hours you want and the load that must run, then divide the energy by the usable share. For 8 hours at 500 W the example needs 1 of the 5.12 kWh modules; at 1 000 W it needs 2. The table above gives the hours for other loads.

What is depth of discharge and why does it change the answer?

Depth of discharge is the share of the rated capacity a maker allows you to use, so the battery is not drained to zero. With 90 % a 5.12 kWh module gives only 4.1 kWh of usable energy once the inverter loss is counted too.

Does the inverter efficiency matter for backup time?

Yes. The battery stores direct current and the house runs on alternating current, so the inverter loses part of the energy. The calculator assumes 0.9, which takes about a tenth off the hours compared with the plain capacity divided by the load.

What happens if the load is bigger than the inverter?

The inverter overloads and shuts down, so the battery cannot help however full it is. The calculator then shows no hours. The example inverter carries up to 5 kW, so add up the appliances that run together and compare with that.

Can the panels extend the backup time?

By day, yes, but by how much depends on the season, the weather and the size of the plant. The calculator leaves the panels out on purpose, so the figure is the worst case. Use the system size calculator for a balance with solar.

Embed on your website

Free. Paste this code into your page and the calculator runs on your site, with no cookies and no data collected.

<script src="https://solispec.com/widget.js" async></script>
<solispec-calc calc="backup" lang="en"><a href="https://solispec.com/en/calculators/backup?src=embed&utm_source=embed&utm_medium=widget&utm_campaign=calc-backup">How long the battery lasts — Solispec</a></solispec-calc>

Ground frame designer

Design the ground frame for your solar plant

The calculator’s values go to the designer: then the frame, the DBN checks and the estimate.