Snow load by city in Ukraine — the S₀ and W₀ table under DBN V.1.2-2

Characteristic snow load S₀ and wind pressure W₀ for the 22 oblast centres and the 40 largest cities of Ukraine, and the formula that turns them into the design load on a pitched roof with μ and γfm, all under DBN V.1.2-2:2006.

By Solispec editorial8 min read

The first thing a mounting design for solar panels on a roof or a ground frame needs is two numbers from DBN V.1.2-2:2006 "Loads and actions": the characteristic snow load S₀ and the characteristic wind pressure W₀ of the site. They are looked up by district on the norm's maps, and that is where most mistakes happen: "1.5 kPa, as in Kyiv" is taken for Chernihiv, where the snow is heavier, or for Kherson, where it is half as heavy. Below are the values for the oblast centres from the Solispec engine, a table for the 40 largest cities, and the formula that turns S₀ into the load on a real roof.

Where S₀ and W₀ come from

DBN V.1.2-2:2006 sets the snow load by snow districts (section 8) and the wind load by wind districts (section 9), with maps in its annex. For the oblast centres the norm gives the characteristic values directly, and that table is what the Solispec engine uses: 22 centres, S₀ and W₀ in pascals. What a characteristic value means is explained in the glossary terms S₀ and W₀: a value with a 50-year return period, before any safety factors.

Pascals look unfamiliar, so the equivalent in kilograms per square metre is given alongside (1 kPa ≈ 102 kg/m²; here Pa / 9.81).

Table: oblast centres

Sorted by snow load. Each city links to its own page with the map, the neighbouring centres and the calculation for a building.

Oblast centreS₀, Pa≈ kg/m²W₀, Pa≈ kg/m²
Chernihiv172017541042
Sumy167017042043
Kharkiv160016343044
Kyiv155015837038
Cherkasy152015542043
Zhytomyr146014946047
Poltava145014847048
Ivano-Frankivsk141014450051
Ternopil139014252053
Vinnytsia136013947048
Dnipro134013747048
Khmelnytskyi134013750051
Uzhhorod134013737038
Chernivtsi132013550051
Rivne132013552053
Lviv131013452053
Lutsk124012648049
Kropyvnytskyi123012541042
Zaporizhzhia111011346047
Odesa8809046047
Mykolaiv8708947048
Kherson7607748049

The ends of the table differ by more than a factor of two: 1720 Pa in Chernihiv against 760 Pa in Kherson. Wind is distributed differently: strongest in the west (Lviv, Ternopil, Rivne at 520 Pa), weakest in Kyiv and Uzhhorod (370 Pa). A project moved from the east to the west "as is" can therefore be overloaded by snow and underloaded by wind.

Table: the 40 largest cities

For a city that is not an oblast centre the engine takes the values of the nearest centre in the table, exactly as the Solispec designer does when you enter an address. The "km" column is the distance to that centre. The cities of Donetsk and Luhansk oblasts and of Crimea are not listed: the engine's table has no rows for them yet, although the norm itself does.

CityOblastDBN table centrekmS₀, PaW₀, Pa
KyivKyiv cityKyiv—1550370
KharkivKharkivKharkiv—1600430
OdesaOdesaOdesa—880460
DniproDnipropetrovskDnipro—1340470
LvivLvivLviv—1310520
ZaporizhzhiaZaporizhzhiaZaporizhzhia—1110460
Kryvyy RihDnipropetrovskKropyvnytskyi1081230410
MykolaivMykolaivMykolaiv—870470
VinnytsiaVinnytsiaVinnytsia—1360470
ChernihivChernihivChernihiv—1720410
PoltavaPoltavaPoltava—1450470
KhmelnytskyiKhmelnytskyiKhmelnytskyi—1340500
CherkasyCherkasyCherkasy—1520420
ChernivtsiChernivtsiChernivtsi—1320500
ZhytomyrZhytomyrZhytomyr—1460460
SumySumySumy—1670420
RivneRivneRivne—1320520
Ivano-FrankivskIvano-FrankivskIvano-Frankivsk—1410500
KamyanskeDnipropetrovskDnipro331340470
TernopilTernopilTernopil—1390520
KremenchukPoltavaPoltava1021450470
KropyvnytskyiKirovohradKropyvnytskyi—1230410
LutskVolynLutsk—1240480
Bila TserkvaKyivKyiv781550370
MelitopolZaporizhzhiaZaporizhzhia1121110460
UzhhorodZakarpattiaUzhhorod—1340370
BrovaryKyivKyiv201550370
BerdyanskZaporizhzhiaZaporizhzhia1741110460
NikopolDnipropetrovskZaporizhzhia641110460
PavlohradDnipropetrovskDnipro611340470
Kamyanets-PodilskyiKhmelnytskyiChernivtsi641320500
MukachevoZakarpattiaUzhhorod371340370
KonotopSumySumy1171670420
UmanCherkasyVinnytsia1391360470
OleksandriyaKirovohradKropyvnytskyi661230410
DrohobychLvivLviv661310520
ShostkaSumySumy1401670420
BerdychivZhytomyrZhytomyr401460460
SamarDnipropetrovskDnipro241340470
IzmayilOdesaOdesa194880460

For a city far from its centre (Kryvyi Rih is 108 km from Kropyvnytskyi, Kremenchuk 102 km from Poltava) the snow district on the norm's map may differ. Then the right value is read from the map and entered as your own S₀ in the calculator.

From S₀ to the load on a pitched roof

The characteristic value is snow on horizontal ground. Formula (8.1) of DBN V.1.2-2:2006 turns it into the limit design value on a tilted roof:

Sm = γfm · S₀ · C_alt · μ

  • γfm is the reliability factor for the limit value, Table 8.1: 1.0 for a mean return period of 50 years, 1.14 for 100 years.
  • C_alt is the altitude factor, formula (8.5): 1 up to 500 m, then 1.4·H + 0.3 (H in km): 1.14 at 600 m, 1.7 at 1000 m.
  • μ is the factor from snow on the ground to snow on the roof, Annex Zh, scheme 1: 1 for a slope up to 25°, 0 from 60°, linear between: μ = (60 − α) / 35. For an array on the ground μ = 1. More in the term factor μ.
  • C_e is the operating-regime factor; for solar arrays the engine takes 1 (cl. 8.9).

An example for Kyiv: S₀ = 1550 Pa, a 35° roof, below 500 m, 50-year life. μ = (60 − 35) / 35 = 0.714; Sm = 1.0 · 1550 · 1 · 0.714 = 1107 Pa, about 113 kg on every square metre of the roof. On a 20° roof μ = 1 and the load is the full 1550 Pa (158 kg/m²). That is what every bracket must carry together with the rail and the panels' weight. The full picture, how the design value enters the check of clamps and rails, is described in the terms design snow load and snow and wind district.

Wind is converted the same way: Wm = γfm · W₀ · C_h · C_alt, where C_h depends on the height above ground and the terrain type (the height factor table in section 9). That pressure goes with DBN’s own aerodynamic coefficients. For panels the coefficients come from EN 1991-1-4, which defines them on the peak pressure, so the wind on them is Wm = γfm · W₀ · c_e(z) · C_alt with the EN 1991-1-4 exposure factor c_e(z); for an array at 2 m in terrain II that is 1.42 in place of C_h = 0.70. Both values for your building are computed by the snow and wind load calculator from the address, height and tilt.

What this means for the mounting

Snow presses the panels onto the roof and loads the rafters; wind tries to lift them, most of all at the roof's edges and corners. In the mounting design both values enter the combinations of cl. 4.18 of the DBN, and the brackets, rails and anchors are checked. For a ground frame the overturning and sliding of the table are checked on top. How this is done for a roof we described in the article on pitched-roof mounting, for the ground in the article on the ground-mount frame. All city pages are collected on the snow and wind loads page, and the norm itself is explained in the overview of DBN V.1.2-2:2006.

Sources

  • DBN V.1.2-2:2006 "Loads and actions" with Changes No. 1 (2007) and No. 2 (2020): section 8 (snow load, formulas (8.1) and (8.5), Table 8.1, Annex Zh), section 9 (wind load, formula (9.1), the height factor C_h), cl. 4.18 (combinations).
  • The Solispec engine's table of oblast centres: the characteristic S₀ and W₀ of the 22 centres in pascals, as the city pages show them.
  • GeoNames (CC BY 4.0): the list and population of the cities from which the 40 largest were chosen; the distance to the centre from the coordinates.
  • DBN V.2.6-198:2014: steel structures, into which the design load passes in the check of the mounting profiles.

Frequently asked questions

What is the snow load in Kyiv?

The characteristic value S₀ for Kyiv is 1550 Pa (about 158 kg/m²), the wind W₀ is 370 Pa. On a 35° roof the design snow load by formula (8.1) with μ = 0.714 is 1107 Pa.

Where in Ukraine is the snow load highest?

Among the oblast centres, in Chernihiv (1720 Pa), Sumy (1670 Pa) and Kharkiv (1600 Pa). The lowest are Kherson (760 Pa), Mykolaiv (870 Pa) and Odesa (880 Pa).

Does the roof pitch reduce the snow load?

Yes: by scheme 1 of Annex Zh the factor μ is 1 up to 25° and falls linearly to 0 at 60°. A 45° roof gets 43 % of the ground snow, a 35° roof 71 %.

How do I convert pascals to kilograms per square metre?

Divide by 9.81: 1550 Pa ≈ 158 kg/m², 1 kPa ≈ 102 kg/m². That is the mass of snow on a square metre of horizontal surface.

What if my city is not in the table?

Take the nearest oblast centre, as the designer does, or find the district on the DBN map and enter your own S₀ in the calculator. For mountain sites above 500 m, C_alt must be applied.

The calculation is preliminary. A qualified engineer must check the system before installation.

StructuresNorms

News and design tips

What’s new in Solispec, changes to the standards and practical tips on designing solar power systems.

What interests you

How we handle your data: privacy policy.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate