Ground-mounted solar panel frame: how to build and size it
A ground-mounted solar panel frame — piles or ballast, profile, height, tilt and row spacing, snow and wind under DBN. Worked example: 20 panels in Kyiv.
A ground-mounted solar panel frame is made of trusses or frames standing on supports — screw piles, concrete blocks or posts set in concrete — and longitudinal rails that carry the panels. The profile, the truss spacing and the type of support are chosen for your site's snow and wind under DBN V.1.2-2, and the depth of the supports for the frost depth of the soil. Below: the types of structure, what to choose, how to set the height, tilt and row spacing, and a worked example for 20 panels in Kyiv computed by our engine.
What a ground mount is made of
Any ground structure for solar panels has four parts:
- supports — what takes the load into the ground: piles, blocks, concrete;
- load-bearing trusses or frames — the inclined rafter, posts, base and strut;
- rails (purlins) — longitudinal profiles the panels lie on;
- braces — crosses between the trusses that keep the row from folding lengthwise.
The trusses stand at equal spacing along the row. The larger the spacing, the fewer trusses and supports, but the longer the rail span and the heavier the load on each truss. So the spacing is not an arbitrary number but the result of a calculation. The overall order of building a plant, from choosing the place to the grid connection, is in the article how to build a home solar plant; here it is only the structure on the ground.
Supports: screw piles, ballast or concrete
Screw piles. The most common choice for a private plot. A pile holds by the soil, not by its own weight: the helix works as an anchor against uplift. In our engine it is a Ø76 × 2000 mm pile with a 200×200 head, two piles under each truss. A pile's capacity depends on the soil, so the value assumed (500 kg per pile) has to be confirmed on site by a trial installation and pull-out. Driven piles work the same way but need machinery to drive them.
Ballast — concrete blocks. The truss stands on heavy elements: lintels, kerbs, FBS foundation blocks or cast cubes. Nothing is dug, but the ballast must outweigh the wind uplift, not tip over and not slide. On an open, windy plot that adds up to many blocks.
Concrete. Two ways. The first is frame posts in bored holes: a Ø350 hole, the post goes 1300 mm into the concrete, gravel at the bottom, a sleeve around, rebar inside. The second is a cast strip under the line of supports, with the trusses fixed to it by anchors. A strip on frost-susceptible soil is designed separately: a shallow strip can be lifted by frost together with the frame.
Depth and frost. A support must go below the frost depth, otherwise the soil pushes it up in winter (frost heave). The engine takes the frost depth of the regional centre under DBN as a reference value: for Kyiv ≈ 1.10 m. A concreted post in Kyiv goes 1300 mm deep — more than 1100. A 2 m pile standing 300 mm out of the ground sits 1.7 m in the soil.
One post or two
A two-post frame is the classic ground table: two posts (front and rear) under an inclined rafter, a strut between them. The posts stand at about 0.21 of the rafter's length from its ends — that way the moment in the span and on the cantilevers comes out about equal. With three or four panel rows up the slope the rafter gets longer, and the engine adds a middle post.
A single-post table carries all the wind and snow on one post that works in bending. It needs a much stronger section and a heavier foundation, and the installation accuracy is critical. Solispec does not calculate single-post tables; for a private plant a two-post frame or a truss is usually simpler.
A truss is a triangle of a rafter, a base, a rear post and an inner strut. It is lighter than a frame because its members work mainly in compression and tension, and it sits well on piles or blocks.
Profile: thin-walled C or tube
Our engine offers two types of profile and checks each under its own standard:
- cold-formed C profile — under EN 1993-1-3: effective section, distortional and flexural-torsional buckling;
- tube — under DBN V.2.6-198.
The C profile is lighter and handier: the rail, the truss and the braces can be one profile, and a perforated C has factory slots for the bolts. A tube is closed and works better in torsion and compression, but its joints are more complex. For a thin-walled profile stability governs, not strength: a member buckles where it is weakest, so each member is checked in both planes. How a truss is checked member by member is in the article how a ground truss is checked.
Height above the ground, tilt and row spacing
Height. The engine requires the bottom of the panel to be at least 300 mm above the soil. That is a minimum, not a recommendation. Snow sliding off the panels collects under the lower edge; if the drift reaches the panel, it holds the rest of the snow on the surface. Tall grass and weeds shade the bottom row of cells, and mowing under a low structure is awkward. For snowy regions and for plots where grass grows, it is sensible to set the bottom at 500–600 mm; the frame in our example below has exactly 600 mm.
Tilt. For annual yield at latitude 50° the optimum is about 35°. But mind the wind: the force coefficient table for canopies in EN 1991-1-4 (Table 7.6), which DBN allows, covers angles of 0–30°. Above 30° the coefficient is extrapolated, and the engine warns about it.
Row spacing. It is set by the winter sun: at noon on 21 December in Kyiv it is only 16.6° above the horizon. For a row of one portrait panel at 34° the row pitch is at least 6370 mm; for two portrait panels at 30°, about 12 030 mm. You can work it out for your latitude, tilt and shade-free window in the calculator tilt angle and row spacing.
Loads: the snow and wind of your site
A frame is calculated for snow, wind and dead weight under DBN V.1.2-2. The values depend on the region: for Kyiv snow S₀ = 1550 Pa, wind W₀ = 370 Pa, and at the height of the panels' top edge, about 1.7 m, the design wind is Wm ≈ 527 Pa (terrain II). The panels’ aerodynamic coefficients come from EN 1991-1-4 and are defined on the peak pressure, so the EN 1991-1-4 exposure factor c_e = 1.42 takes the place of the DBN height factor. For other cities, see the calculator snow and wind load or a city page, for example Kyiv.
Both combinations are checked — snow leading and wind leading — and the wind both ways: pressure onto the panel face and uplift. For a ground frame on piles it is often the uplift that governs: it sets the capacity the supports need.
Bolts and joints
In Solispec frames every profile connection is an M10 bolt, class 8.8 in the frames. Two rules the engine keeps without exception:
- one hole — one bolt;
- no profile passes through another — neither through a neighbouring member nor through a support.
In a perforated C profile the truss joint's bolt goes through the common factory slot of both profiles, without drilling. A second bolt does not fit in such a joint — the axes of the two profiles cross at one point — so the truss is calculated with pinned joints and the joint force is checked on one bolt. Hence a limit: the tilt must be such that the joint holes fall into the slots. The truss calculator suggests the nearest angle at which they do. In a solid C profile the holes are drilled, and the engine puts two bolts per joint.
Corrosion protection
A frame stands outdoors for twenty years or more, so all the steel must be galvanised: profile, piles, bolts, nuts and washers. The weak spots are cuts and drilled holes: there is no zinc there. They are cleaned and coated with zinc-rich paint or a cold-galvanising spray; the engine adds it to the estimate. The bolts of the panel clamps are stainless. Do not leave the profile in contact with wet soil: the foot of a post or the head of a pile should be above the ground.
Example: 20 panels in Kyiv
Inputs: Kyiv, 20 panels of 2350×1100 mm at 550 W (11 kW), terrain II, 150 m above sea level. The numbers below come from our engine, the same checks as in the solar panel truss calculator and the configurator.
Option 1: two portrait rows of 10 panels, a frame with concreted posts. Tilt 30°, panel bottom 600 mm, top 2990 mm. The engine sets 7 frames at 1800 mm spacing, 14 posts of 60×60×2 tube in total, the rafter a C 100×50×2.5, purlins and braces C 60×40×2. The footing is Ø350 × 1300 mm per post, 1.93 m³ of concrete with a 10 % margin. The most loaded element is the purlin: strength 53 %, deflection 21 % of the limit. The rafter is at 23 %, the rear post at 13 %, the footing in uplift at 19 %. Steel: 31 bars of 6 m.
Option 2: the same 20 panels on trusses on screw piles. Here a truss carries one portrait panel up the slope, and the engine's table has six trusses. Put all 10 panels of a row on one table and the truss spacing comes to 2060 mm, and the check fails: the rail at 149 %, the rafter at 130 %. The engine suggests fewer panels per table. With five panels per table the truss spacing is 1040 mm and everything passes:
- 4 tables of 5 panels at 34°, 24 trusses of perforated C 41×41×2;
- 48 piles Ø76 × 2000 mm — two under each truss;
- steel ≈ 540 kg (the engine's estimate), 39 bars of 6 m;
- the weakest member is the rafter: 76 %; the rail 46 %, the joint 22 %;
- wind uplift per table ≈ 461 kg against an assumed capacity of 6000 kg (500 kg per pile — confirm on site);
- panel bottom 317 mm, row pitch at least 6370 mm.
The conclusion for this plot: the two-row frame takes less ground but needs drilling and concrete; trusses on piles go in without concrete but take more room with four rows and need the soil under the piles checked. What ground plants look like for different cities is on the page ground-mounted plant.
The calculation is preliminary. A qualified engineer must check it before installation.
Common mistakes
- A profile "like the neighbour's". Snow in Chernihiv and in Odesa differs almost twofold; a frame that stands at one place may bend at the other.
- Supports shallower than the frost depth. The very first winter lifts one support, and the truss twists.
- Too wide a truss spacing. The rail on a long span fails first, as in option 2.
- Panel bottoms almost on the ground. Drifts and grass take the yield, and the profile rots in wet soil.
- Drilling on site without protection. Every unpainted cut and hole is where rust starts.
- Two bolts in one hole or a profile through a profile. A joint that cannot be assembled as drawn does not work as calculated.
- Rows too close together. In winter the back row in the front row's shadow loses most exactly when energy is short.
If the panels are going on a roof rather than the ground, read the separate article on mounting solar panels on a roof.
Frequently asked questions
How deep should piles for solar panels go?
The pile's helix must be below the soil's frost depth in your region: for Kyiv it is about 1.1 m by the DBN reference value. A 2 m pile standing 300 mm out of the ground sits 1.7 m in the soil. The capacity is finally confirmed by a trial installation on site.
How high should ground-mounted panels be?
No lower than 300 mm from the soil to the panel's lower edge — that is the minimum our engine checks. Where there is a lot of snow or grass grows, 500–600 mm is better.
Which is better: piles or concrete blocks?
Piles hold by the soil and need no heavy machinery on site, but they depend on the soil. Blocks hold by weight and suit places where you cannot dig; on a windy plot you need many of them. Both are checked for uplift, and blocks also for overturning and sliding.
Can I build the frame myself?
Yes, if the profile, truss spacing and supports are chosen by calculation for your site and the joints are assembled to the drawing. Building it yourself does not cancel the check: what is checked and in what order is in the article on checking a truss.
What tilt should a ground plant have?
For annual yield at latitude 50°, about 35°; further south, a little less. A steeper angle gives slightly more in winter but raises the wind load and the row spacing.