Solar power plant in Kalynivka, Berdianskyi Raion, Zaporizhzhia Oblast

Kalynivka: 1,227 kWh per kWp a year, tilt 36° facing south (PVGIS). 1.2% above the oblast median (1,212). #54 of 116 in the rayon, #242 of 972 in the oblast.

Berdyansk, the rayon centre, is 54 km away. 107 m above sea level. 45 km away: Pryazovske, the nearest bigger centre, 1,254 — 2.2% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 124 km. 9.53 m between rows, pitch 13.40 m (latitude 47.0°).

Yield of 1 kWp
1,227kWh/year
Tilt
36°facing south
10 kW
12,266kWh/year
Row pitch
13.40m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Kalynivka

The designer opens with this place’s coordinates, latitude 47.0° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 124 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan59Feb100Mar122Apr143May143Jun152Jul153Aug128Sep98Oct56Nov34Dec

August: 153 kWh/kWp, December: 34 — 4.5 times less.

December: 34 against 32 in the oblast, 6.3% more.

Kalynivka: plants, kWh
kWpA yearAugustDecember
56,133765170
1012,2661,530340
1518,3992,295510

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.