Solar plant: site data

Solar power plant in Stobykhivka, Kamin-Kashyrskyi Raion, Volyn Oblast

Stobykhivka: 1,060 kWh per kWp a year, tilt 38° 4° east of south (PVGIS). 2.2% below the oblast median (1,084). #108 of 167 in the rayon, #1032 of 1120 in the oblast.

Kamin-Kashyrskyi, the rayon centre, is 28 km away. 164 m above sea level. 26 km away: Kovel, the nearest bigger centre, 1,079 — 1.7% less here. Snow and wind from the nearest regional centre in the DBN — Луцьк, 73 km. 13.82 m between rows, pitch 17.59 m (latitude 51.4°).

Yield of 1 kWp
1,060kWh/year
Tilt
38°4° east of south
10 kW
10,604kWh/year
Row pitch
17.59m · GCR 0.27
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,240 / 480Pa

Ground frame designer

A ground frame for a solar plant: Stobykhivka

The designer opens with this place’s coordinates, latitude 51.4° for the row spacing and the DBN loads of the nearest regional centre — Луцьк, 73 km: snow 1,240 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan51Feb95Mar114Apr126May132Jun132Jul132Aug104Sep76Oct35Nov27Dec

June: 132 kWh/kWp, December: 27 — 4.9 times less.

November: 35 against 37 in the oblast, 5.4% less.

Stobykhivka: plants, kWh
kWpA yearJuneDecember
55,302660135
1010,6041,320270
1515,9061,980405

Snow and wind: Луцьк

Example: a 10 kW ground frame

For the loads of Lutsk: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamin-Kashyrskyi RaionVolyn Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.