Solar plant: site data

Solar power plant in Radoshynka, Kamin-Kashyrskyi Raion, Volyn Oblast

Radoshynka: 1,065 kWh per kWp a year, tilt 38° 4° east of south (PVGIS). 1.8% below the oblast median (1,084). #85 of 167 in the rayon, #955 of 1120 in the oblast.

Kamin-Kashyrskyi, the rayon centre, is 26 km away. 165 m above sea level. 26 km away: Kamin-Kashyrskyi, the nearest bigger centre, 1,058 — 0.7% more here. Snow and wind from the nearest regional centre in the DBN — Луцьк, 76 km. 13.85 m between rows, pitch 17.62 m (latitude 51.4°).

Yield of 1 kWp
1,065kWh/year
Tilt
38°4° east of south
10 kW
10,654kWh/year
Row pitch
17.62m · GCR 0.27
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,240 / 480Pa

Ground frame designer

A ground frame for a solar plant: Radoshynka

The designer opens with this place’s coordinates, latitude 51.4° for the row spacing and the DBN loads of the nearest regional centre — Луцьк, 76 km: snow 1,240 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan52Feb95Mar115Apr127May132Jun133Jul133Aug105Sep77Oct36Nov28Dec

July: 133 kWh/kWp, December: 28 — 4.8 times less.

October: 77 against 80 in the oblast, 3.8% less.

Radoshynka: plants, kWh
kWpA yearJulyDecember
55,327665140
1010,6541,330280
1515,9811,995420

Snow and wind: Луцьк

Example: a 10 kW ground frame

For the loads of Lutsk: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamin-Kashyrskyi RaionVolyn Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.