Solar plant: site data
Solar power plant in Marazliivka, Bilhorod-Dnistrovskyi Raion, Odesa Oblast
Marazliivka: 1,310 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 7.3% above the oblast median (1,221). #26 of 134 in the rayon, #39 of 1177 in the oblast.
Bilhorod-Dnistrovskyi, the rayon centre, is 49 km away. 11 m above sea level. 49 km away: Bilhorod-Dnistrovskyi, the nearest bigger centre, 1,288 — 1.7% more here. Snow and wind from the nearest regional centre in the DBN — Одеса, 92 km. 8.91 m between rows, pitch 12.78 m (latitude 45.9°).
- Yield of 1 kWp
- 1,310kWh/year
- Tilt
- 36°1° east of south
- 10 kW
- 13,098kWh/year
- Row pitch
- 12.78m · GCR 0.37
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 880 / 460Pa
Ground frame designer
A ground frame for a solar plant: Marazliivka
The designer opens with this place’s coordinates, latitude 45.9° for the row spacing and the DBN loads of the nearest regional centre — Одеса, 92 km: snow 880 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 155 kWh/kWp, December: 47 — 3.3 times less.
December: 47 against 38 in the oblast, 23.7% more.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 6,549 | 775 | 235 |
| 10 | 13,098 | 1,550 | 470 |
| 15 | 19,647 | 2,325 | 705 |
Example: a 10 kW ground frame
For the loads of Odesa: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.
How these numbers are computed
Nearby
- Charychanka2 km1,319 kWh/kWp
- Nove3 km1,293 kWh/kWp
- Zhovtyi Yar3 km1,319 kWh/kWp
- Roilianka5 km1,316 kWh/kWp
- Lyman6 km1,302 kWh/kWp
- Dyviziya8 km1,303 kWh/kWp
All places: Bilhorod-Dnistrovskyi RaionOdesa Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.