Solar plant: site data

Solar power plant in Novopavlivka, Mykolaivskyi Raion, Mykolaiv Oblast

Novopavlivka: 1,202 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). Exactly the oblast median (1,198). #223 of 238 in the rayon, #397 of 909 in the oblast.

Mykolayiv, the rayon centre, is 51 km away. 39 m above sea level. 10 km away: Nova Odesa, the nearest bigger centre, 1,212 — 0.8% less here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 52 km. 9.81 m between rows, pitch 13.68 m (latitude 47.4°).

Yield of 1 kWp
1,202kWh/year
Tilt
36°4° east of south
10 kW
12,024kWh/year
Row pitch
13.68m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Novopavlivka

The designer opens with this place’s coordinates, latitude 47.4° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 52 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan57Feb102Mar124Apr140May140Jun152Jul148Aug124Sep96Oct48Nov32Dec

July: 152 kWh/kWp, December: 32 — 4.8 times less.

February: 57 against 54 in the oblast, 5.6% more.

Novopavlivka: plants, kWh
kWpA yearJulyDecember
56,012760160
1012,0241,520320
1518,0362,280480

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.