Solar plant: site data

Solar power plant in Zadornoye, Yevpatoriiskyi Raion, Autonomous Republic of Crimea

Zadornoye: 1,307 kWh per kWp a year, tilt 36° 3° west of south (PVGIS). 1.8% above the oblast median (1,284). #95 of 120 in the rayon, #290 of 1025 in the oblast.

Yevpatoriya, the rayon centre, is 44 km away. 71 m above sea level. 33 km away: Rozdolne, the nearest bigger centre, 1,319 — 0.9% less here. Snow and wind from the nearest regional centre in the DBN — Херсон, 126 km. 8.75 m between rows, pitch 12.62 m (latitude 45.6°).

Yield of 1 kWp
1,307kWh/year
Tilt
36°3° west of south
10 kW
13,073kWh/year
Row pitch
12.62m · GCR 0.38
T_min
-27 °Cregion V, Crimean Mountains
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Zadornoye

The designer opens with this place’s coordinates, latitude 45.6° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 126 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

47Jan63Feb112Mar134Apr149May145Jun158Jul157Aug134Sep103Oct62Nov43Dec

July: 158 kWh/kWp, December: 43 — 3.7 times less.

March: 112 against 106 in the oblast, 5.7% more.

Zadornoye: plants, kWh
kWpA yearJulyDecember
56,537790215
1013,0731,580430
1519,6102,370645

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Yevpatoriiskyi RaionAutonomous Republic of Crimea: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.