Solar plant: site data

Solar power plant in Ruch’i, Perekopskyi Raion, Autonomous Republic of Crimea

Ruch’i: 1,303 kWh per kWp a year, tilt 36° 2° west of south (PVGIS). 1.5% above the oblast median (1,284). #47 of 84 in the rayon, #323 of 1025 in the oblast.

Yany Kapu, the rayon centre, is 21 km away. 7 m above sea level. 13 km away: Rozdolne, the nearest bigger centre, 1,319 — 1.2% less here. Snow and wind from the nearest regional centre in the DBN — Херсон, 125 km. 8.86 m between rows, pitch 12.73 m (latitude 45.8°).

Yield of 1 kWp
1,303kWh/year
Tilt
36°2° west of south
10 kW
13,027kWh/year
Row pitch
12.73m · GCR 0.38
T_min
-27 °Cregion V, Crimean Mountains
Snow S₀ / wind W₀
760 / 480Pa

Ground frame designer

A ground frame for a solar plant: Ruch’i

The designer opens with this place’s coordinates, latitude 45.8° for the row spacing and the DBN loads of the nearest regional centre — Херсон, 125 km: snow 760 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

48Jan61Feb110Mar133Apr149May146Jun159Jul158Aug134Sep101Oct61Nov43Dec

July: 159 kWh/kWp, December: 43 — 3.7 times less.

February: 61 against 64 in the oblast, 4.7% less.

Ruch’i: plants, kWh
kWpA yearJulyDecember
56,514795215
1013,0271,590430
1519,5412,385645

Snow and wind: Херсон

Example: a 10 kW ground frame

For the loads of Kherson: 11.16 kWp, 18 panels, 349 kg of steel, 12 piles, materials ≈ 47,980 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Perekopskyi RaionAutonomous Republic of Crimea: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.