Solar plant: site data

Solar power plant in Sel’tso, Shepetivskyi Raion, Khmelnytskyi Oblast

Sel’tso: 1,065 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 3.2% below the oblast median (1,100). #304 of 307 in the rayon, #1106 of 1109 in the oblast.

Shepetivka, the rayon centre, is 30 km away. 209 m above sea level. 13 km away: Slavuta, the nearest bigger centre, the same 1,070. Snow and wind from the nearest regional centre in the DBN — Рівне, 47 km. 12.37 m between rows, pitch 16.19 m (latitude 50.3°).

Yield of 1 kWp
1,065kWh/year
Tilt
37°2° east of south
10 kW
10,654kWh/year
Row pitch
16.19m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 520Pa

Ground frame designer

A ground frame for a solar plant: Sel’tso

The designer opens with this place’s coordinates, latitude 50.3° for the row spacing and the DBN loads of the nearest regional centre — Рівне, 47 km: snow 1,320 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan52Feb89Mar114Apr127May130Jun133Jul133Aug108Sep80Oct36Nov28Dec

July: 133 kWh/kWp, December: 28 — 4.8 times less.

January: 34 against 32 in the oblast, 6.3% more.

Sel’tso: plants, kWh
kWpA yearJulyDecember
55,327665140
1010,6541,330280
1515,9811,995420

Snow and wind: Рівне

Example: a 10 kW ground frame

For the loads of Rivne: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shepetivskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.