Solar power plant in Kolomie, Shepetivskyi Raion, Khmelnytskyi Oblast

Kolomie: 1,078 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 2.0% below the oblast median (1,100). #278 of 307 in the rayon, #1056 of 1109 in the oblast.

Shepetivka, the rayon centre, is 28 km away. 215 m above sea level. 9 km away: Slavuta, the nearest bigger centre, 1,070 — 0.8% more here. Snow and wind from the nearest regional centre in the DBN — Рівне, 48 km. 12.41 m between rows, pitch 16.23 m (latitude 50.3°).

Yield of 1 kWp
1,078kWh/year
Tilt
37°2° east of south
10 kW
10,783kWh/year
Row pitch
16.23m · GCR 0.29
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 520Pa

Ground frame designer

A ground frame for a solar plant: Kolomie

The designer opens with this place’s coordinates, latitude 50.3° for the row spacing and the DBN loads of the nearest regional centre — Рівне, 48 km: snow 1,320 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan55Feb90Mar116Apr129May131Jun134Jul134Aug109Sep81Oct36Nov29Dec

July: 134 kWh/kWp, December: 29 — 4.6 times less.

January: 35 against 32 in the oblast, 9.4% more.

Kolomie: plants, kWh
kWpA yearJulyDecember
55,392670145
1010,7831,340290
1516,1752,010435

Snow and wind: Рівне

Example: a 10 kW ground frame

For the loads of Rivne: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shepetivskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.