Solar plant: site data

Solar power plant in Hubcha, Khmelnytskyi Raion, Khmelnytskyi Oblast

Hubcha: 1,087 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.2% below the oblast median (1,100). #452 of 576 in the rayon, #891 of 1109 in the oblast.

Khmelnytskyi, the rayon centre, is 56 km away. 283 m above sea level. 17 km away: Starokostyantyniv, the nearest bigger centre, 1,094 — 0.6% less here. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 55 km. 11.72 m between rows, pitch 15.59 m (latitude 49.9°).

Yield of 1 kWp
1,087kWh/year
Tilt
36°2° east of south
10 kW
10,871kWh/year
Row pitch
15.59m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,340 / 500Pa

Ground frame designer

A ground frame for a solar plant: Hubcha

The designer opens with this place’s coordinates, latitude 49.9° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 55 km: snow 1,340 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

28Jan48Feb84Mar118Apr135May139Jun141Jul137Aug111Sep84Oct37Nov26Dec

July: 141 kWh/kWp, December: 26 — 5.4 times less.

January: 28 against 32 in the oblast, 12.5% less.

Hubcha: plants, kWh
kWpA yearJulyDecember
55,436705130
1010,8711,410260
1516,3062,115390

Snow and wind: Хмельницький

Example: a 10 kW ground frame

For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Khmelnytskyi RaionKhmelnytskyi Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.