Solar plant: site data

Solar power plant in Krasnoillia, Verkhovynskyi Raion, Ivano-Frankivsk Oblast

Krasnoillia: 1,056 kWh per kWp a year, tilt 37° 7° west of south (PVGIS). 3.7% below the oblast median (1,097). #26 of 41 in the rayon, #610 of 700 in the oblast.

Verkhovyna, the rayon centre, is 9 km away. 556 m above sea level — above 500 m the DBN snow and wind are higher. 9 km away: Verkhovyna, the nearest bigger centre, 1,074 — 1.7% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 78 km. 10.54 m between rows, pitch 14.36 m (latitude 48.1°).

Yield of 1 kWp
1,056kWh/year
Tilt
37°7° west of south
10 kW
10,559kWh/year
Row pitch
14.36m · GCR 0.33
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Krasnoillia

The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 78 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

46Jan59Feb89Mar105Apr113May115Jun123Jul122Aug103Sep84Oct56Nov41Dec

July: 123 kWh/kWp, December: 41 — 3.0 times less.

November: 56 against 48 in the oblast, 16.7% more.

Krasnoillia: plants, kWh
kWpA yearJulyDecember
55,280615205
1010,5591,230410
1515,8391,845615

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Verkhovynskyi RaionIvano-Frankivsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.