Solar plant: site data

Solar power plant in Chorna Richka, Verkhovynskyi Raion, Ivano-Frankivsk Oblast

Chorna Richka: 1,041 kWh per kWp a year, tilt 36° 5° east of south (PVGIS). 5.1% below the oblast median (1,097). #28 of 41 in the rayon, #635 of 700 in the oblast.

Verkhovyna, the rayon centre, is 7 km away. 735 m above sea level — above 500 m the DBN snow and wind are higher. 7 km away: Verkhovyna, the nearest bigger centre, 1,074 — 3.0% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 83 km. 10.28 m between rows, pitch 14.15 m (latitude 48.1°).

Yield of 1 kWp
1,041kWh/year
Tilt
36°5° east of south
10 kW
10,412kWh/year
Row pitch
14.15m · GCR 0.34
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Chorna Richka

The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 83 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan64Feb92Mar107Apr113May115Jun123Jul122Aug103Sep85Oct48Nov30Dec

July: 123 kWh/kWp, December: 30 — 4.1 times less.

December: 30 against 38 in the oblast, 21.1% less.

Chorna Richka: plants, kWh
kWpA yearJulyDecember
55,206615150
1010,4121,230300
1515,6181,845450

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Verkhovynskyi RaionIvano-Frankivsk Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.