Spain: solar plant site data

Solar power plant in Albacete, Spain: yield, tilt angle and row spacing

Albacete: 1,657 kWh per kWp a year at the optimal tilt of 36°, 4° east of south (PVGIS). 2.6% above the median of the main cities of Spain (1,615). #33 of 147 main cities of Spain by yield. For comparison, Kyiv: 1,114 kWh/kWp — 48.7% more here.

Albacete is in the province of Albacete, Castilla–La Mancha. Population 173,050 (GeoNames). 695 m above sea level. 129 km away: Murcia, the nearest bigger city, 1,630 kWh/kWp — 1.6% more here. 6.20 m between rows, pitch 10.07 m, GCR 0.48 (latitude 39.0°).

Yield of 1 kWp
1,657kWh/year
Tilt
36°4° east of south
10 kW
16,569kWh/year
Row pitch
10.07m · GCR 0.48
Rank in the country
33of 147 cities

Ground frame designer

A ground frame for a solar plant: Albacete

Latitude 39.0°: the tilt and the row pitch follow it. Enter the snow and wind for Spain in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

115Jan117Feb141Mar145Apr156May156Jun167Jul164Aug146Sep133Oct110Nov107Dec

July: 167 kWh/kWp, December: 107 — 1.6 times less.

November: 110 against the median of 103 for the main cities of Spain, 6.8% more.

Albacete: plants, kWh
kWpA yearJulyDecember
58,285835535
1016,5691,6701,070
1524,8542,5051,605

Fixed tilt facing south

What a table yields at another tilt than the optimal 36° — for roofs and frames with a standard slope.

Albacete: yield at a fixed tilt, kWh/kWp
TiltA yearAgainst the optimum
36° (optimum)1,657—
15°1,569−5.3%
30°1,648−0.5%
45°1,642−0.9%
90°1,084−34.6%

Snow and wind loads

Snow and wind loads for a site in Spain follow CTE DB SE-AE (Spain’s Código Técnico de la Edificación) and, where the Eurocodes are applied, UNE-EN 1991-1-3 and UNE-EN 1991-1-4 with the Spanish National Annex. Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Spain: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.

Nearby cities

Spain: all cities and regions

Sources

Preliminary calculation: a design needs an engineer’s check.