Spain: solar plant site data
Solar power plant in Murcia, Spain: yield, tilt angle and row spacing
Murcia: 1,630 kWh per kWp a year at the optimal tilt of 35°, 1° west of south (PVGIS). 0.9% above the median of the main cities of Spain (1,615). #56 of 147 main cities of Spain by yield. For comparison, Kyiv: 1,114 kWh/kWp — 46.3% more here.
Murcia is in Region of Murcia. Population 471,982 (GeoNames). 53 m above sea level. 178 km away: Valencia, the nearest bigger city, the same 1,632 kWh/kWp. 5.78 m between rows, pitch 9.70 m, GCR 0.49 (latitude 38.0°).
- Yield of 1 kWp
- 1,630kWh/year
- Tilt
- 35°1° west of south
- 10 kW
- 16,303kWh/year
- Row pitch
- 9.70m · GCR 0.49
- Rank in the country
- 56of 147 cities
Ground frame designer
A ground frame for a solar plant: Murcia
Latitude 38.0°: the tilt and the row pitch follow it. Enter the snow and wind for Spain in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 161 kWh/kWp, December: 110 — 1.5 times less.
January: 121 against the median of 109 for the main cities of Spain, 11.0% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 8,152 | 805 | 550 |
| 10 | 16,303 | 1,610 | 1,100 |
| 15 | 24,455 | 2,415 | 1,650 |
Fixed tilt facing south
What a table yields at another tilt than the optimal 35° — for roofs and frames with a standard slope.
| Tilt | A year | Against the optimum |
|---|---|---|
| 35° (optimum) | 1,630 | — |
| 15° | 1,549 | −5.0% |
| 30° | 1,624 | −0.4% |
| 45° | 1,614 | −1.0% |
| 90° | 1,058 | −35.1% |
Snow and wind loads
Snow and wind loads for a site in Spain follow CTE DB SE-AE (Spain’s Código Técnico de la Edificación) and, where the Eurocodes are applied, UNE-EN 1991-1-3 and UNE-EN 1991-1-4 with the Spanish National Annex. Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Spain: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: CTE DB SE-AE