Spain: solar plant site data

Solar power plant in Murcia, Spain: yield, tilt angle and row spacing

Murcia: 1,630 kWh per kWp a year at the optimal tilt of 35°, 1° west of south (PVGIS). 0.9% above the median of the main cities of Spain (1,615). #56 of 147 main cities of Spain by yield. For comparison, Kyiv: 1,114 kWh/kWp — 46.3% more here.

Murcia is in Region of Murcia. Population 471,982 (GeoNames). 53 m above sea level. 178 km away: Valencia, the nearest bigger city, the same 1,632 kWh/kWp. 5.78 m between rows, pitch 9.70 m, GCR 0.49 (latitude 38.0°).

Yield of 1 kWp
1,630kWh/year
Tilt
35°1° west of south
10 kW
16,303kWh/year
Row pitch
9.70m · GCR 0.49
Rank in the country
56of 147 cities

Ground frame designer

A ground frame for a solar plant: Murcia

Latitude 38.0°: the tilt and the row pitch follow it. Enter the snow and wind for Spain in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

121Jan114Feb139Mar142Apr155May155Jun161Jul156Aug137Sep129Oct113Nov110Dec

July: 161 kWh/kWp, December: 110 — 1.5 times less.

January: 121 against the median of 109 for the main cities of Spain, 11.0% more.

Murcia: plants, kWh
kWpA yearJulyDecember
58,152805550
1016,3031,6101,100
1524,4552,4151,650

Fixed tilt facing south

What a table yields at another tilt than the optimal 35° — for roofs and frames with a standard slope.

Murcia: yield at a fixed tilt, kWh/kWp
TiltA yearAgainst the optimum
35° (optimum)1,630—
15°1,549−5.0%
30°1,624−0.4%
45°1,614−1.0%
90°1,058−35.1%

Snow and wind loads

Snow and wind loads for a site in Spain follow CTE DB SE-AE (Spain’s Código Técnico de la Edificación) and, where the Eurocodes are applied, UNE-EN 1991-1-3 and UNE-EN 1991-1-4 with the Spanish National Annex. Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Spain: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.

Nearby cities

Spain: all cities and regions

Sources

Preliminary calculation: a design needs an engineer’s check.