Germany: solar plant site data

Solar power plant in Witten, Germany: yield, tilt angle and row spacing

Witten: 1,012 kWh per kWp a year at the optimal tilt of 39°, 2° east of south (PVGIS). 3.1% below the median of the main cities of Germany (1,045). #155 of 193 main cities of Germany by yield. For comparison, Kyiv: 1,114 kWh/kWp — 9.1% less here.

Witten is in North Rhine-Westphalia. Population 91,808 (GeoNames). 119 m above sea level. 10 km away: Bochum, the nearest bigger city, 1,020 kWh/kWp — 0.7% less here. 14.21 m between rows, pitch 17.93 m, GCR 0.27 (latitude 51.4°).

Yield of 1 kWp
1,012kWh/year
Tilt
39°2° east of south
10 kW
10,123kWh/year
Row pitch
17.93m · GCR 0.27
Rank in the country
155of 193 cities

Ground frame designer

A ground frame for a solar plant: Witten

Latitude 51.4°: the tilt and the row pitch follow it. Enter the snow and wind for Germany in the designer, by the national annex to the Eurocode.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan53Feb89Mar114Apr123May123Jun122Jul114Aug97Sep71Oct43Nov29Dec

May: 123 kWh/kWp, December: 29 — 4.2 times less.

February: 53 against the median of 56 for the main cities of Germany, 5.4% less.

Witten: plants, kWh
kWpA yearMayDecember
55,062615145
1010,1231,230290
1515,1851,845435

Snow and wind loads

Snow and wind loads for a site in Germany follow DIN EN 1991-1-3/NA (snow load zone, Schneelastzone) and DIN EN 1991-1-4/NA (wind zone, Windzone). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Germany: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.

The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.

Nearby cities

Germany: all cities and regions

Sources

Preliminary calculation: a design needs an engineer’s check.