Solar plant: site data

Solar power plant in Trostianets, Cherkaskyi Raion, Cherkasy Oblast

Trostianets: 1,138 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 0.5% below the oblast median (1,144). #187 of 207 in the rayon, #554 of 731 in the oblast.

Cherkasy, the rayon centre, is 63 km away. 126 m above sea level. 9 km away: Kaniv, the nearest bigger centre, the same 1,143. Snow and wind from the nearest regional centre in the DBN — Черкаси, 63 km. 11.88 m between rows, pitch 15.70 m (latitude 49.8°).

Yield of 1 kWp
1,138kWh/year
Tilt
37°3° east of south
10 kW
11,378kWh/year
Row pitch
15.70m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,520 / 420Pa

Ground frame designer

A ground frame for a solar plant: Trostianets

The designer opens with this place’s coordinates, latitude 49.8° for the row spacing and the DBN loads of the nearest regional centre — Черкаси, 63 km: snow 1,520 Pa, wind 420 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan59Feb97Mar117Apr138May141Jun144Jul141Aug114Sep83Oct38Nov28Dec

July: 144 kWh/kWp, December: 28 — 5.1 times less.

January: 38 against 35 in the oblast, 8.6% more.

Trostianets: plants, kWh
kWpA yearJulyDecember
55,689720140
1011,3781,440280
1517,0672,160420

Snow and wind: Черкаси

Example: a 10 kW ground frame

For the loads of Cherkasy: 11.16 kWp, 18 panels, 346 kg of steel, 12 piles, materials ≈ 51,820 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Cherkaskyi RaionCherkasy Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.