The Polish national annexes to PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) give a plot’s zone and the values s_k and q_b from which the loads on mounting structures, on roofs and on the ground, are built. This page explains what a designer takes from them and works one example with the values of the Solispec program.
Updated:
Scope: what the national annexes fix
The European parts EN 1991-1-3 and EN 1991-1-4 leave the countries the choice of nationally determined parameters. The Polish annex to the snow standard fixes five ground snow load zones with formulas for s_k by altitude above sea level (Table NB.1); the annex to the wind standard fixes three wind zones with v_b,0 and q_b,0 (Table NA.1). Zone borders follow county (powiat) boundaries.
The wind annex gives formulas with an altitude term above 300 m in zones 1 and 3; the sources show no explicit upper altitude limit.
What a PV designer takes from it
- the snow and wind zone of the plot (county) and its altitude above sea level
- s_k from the zone formula and q_b,0 from the wind zone; the tables per zone and altitude are on the page “Snow and wind zones in Poland”
- the shape coefficient μ₁ for the tilted module (0.8 up to 30° tilt, falling linearly to 0 at 60°) and the drift and sliding loads at parapets and behind rows to Annex B of EN 1991-1-3
- the peak velocity pressure q_p(z) = c_e(z) · q_b for the terrain category and the height of the structure, and the pressure coefficients for tilted modules
- the design values to EN 1990 (γ_Q = 1.5 for variable actions)
The zone map in words
Snow zone 1 is Lower Silesia and the Lubusz region (Wrocław, Opole, Zielona Góra, Legnica), zone 2 most of central Poland (Warsaw, Łódź, Poznań, Szczecin), zone 3 parts of the south and east (Kraków, Lublin, Rzeszów) and the coast at Gdańsk and Gdynia, zone 4 the north-east (Białystok, Olsztyn, Suwałki, Ełk); zone 5 is the Tatras. Wind zone 2 is the Baltic coastal belt (Gdańsk, Szczecin, Gdynia), zone 3 the Sudetes and the southern Carpathians (Bielsko-Biała, Wałbrzych, Nowy Sącz), the rest of the country is in zone 1. These are the zones of the cities in Solispec’s dataset; a plot’s zone comes from the annex map.
Worked example: Kraków
Kraków lies at 219 m above sea level, in snow zone 3 and wind zone 1. The calculation gives s_k = 1.20 kN/m² and q_b = 0.30 kN/m². On a module tilted 30° μ₁ = 0.8: the snow load on the module surface is 0.96 kN/m², the design value with γ_Q = 1.5 is 1.44 kN/m².
For wind the calculation gives, for terrain category II (open country) and III (suburban buildings), the peak velocity pressure q_p by height z above ground:
| Height z, m | c_e (II) | q_p (II), kN/m² | c_e (III) | q_p (III), kN/m² |
|---|---|---|---|---|
| 3 | 1.64 | 0.49 | 1.28 | 0.38 |
| 6 | 2.04 | 0.61 | 1.39 | 0.42 |
| 10 | 2.35 | 0.71 | 1.71 | 0.51 |
What changed and the special cases
- Snow: the edition PN-EN 1991-1-3:2005 is supplemented by AC:2009 and Ap1:2010; the zone values are in the national annex
- Wind: on the border of zones 1 and 2 map NA.1 has a transition band; Solispec’s data treats it as zone 2
- Wind zone 3 above 300 m includes the drop in air density in q_b,0
Checklist for the design
- County and the plot’s altitude above sea level noted
- Snow and wind zone read from the national annex maps (county), not only the voivodeship
- Special cases checked: zones 1 and 3 above 300 m, zone 5 in the Tatras, the transition band of the wind zones
- s_k and q_b from formula and table, cross-checked with the page “Zones in Poland”
- μ₁, drift behind rows and at parapets and sliding snow applied
- Terrain category and height of the structure set for q_p(z), pressure coefficients for tilted modules chosen
- Design values formed with γ_Q = 1.5 and the design checked by a structural engineer
Frequently asked questions
What does PN-EN 1991-1-3 with its national annex regulate?
Snow load: five zones, formulas for s_k by altitude above sea level and roof shape coefficients. The zones follow the map of the national annex.
What does PN-EN 1991-1-4 with its national annex regulate?
Wind actions: three wind zones, the basic velocity v_b,0 and pressure q_b,0 and the altitude correction in zones 1 and 3.
Where do I get my plot’s zone?
From the maps of the national annex; zone borders follow county boundaries, so the county the plot lies in decides.
Does s_k apply on the module?
No, s_k is the load on the ground. On a tilted module it is multiplied by μ₁, in the example 1.20 kN/m² times 0.8 gives 0.96 kN/m². Drift and sliding snow come on top.
Is the calculation on this page enough for a structural design?
No. It shows the method and guide values. A structural engineer does the calculation for the plot to the country’s standards.
Sources: the standards
- PN-EN 1991-1-3:2005 + NA (+AC:2009, Ap1:2010), Eurokod 1: Oddziaływania na konstrukcje, Część 1-3: Oddziaływania ogólne, Obciążenie śniegiem
- PN-EN 1991-1-4:2008 + NA, Eurokod 1: Oddziaływania na konstrukcje, Część 1-4: Oddziaływania ogólne, Oddziaływania wiatru
- Snow and wind zones: the tables
- Snow load on a flat roof with PV panels, Poland
- Snow and wind load calculator
- Ground-mount frame calculator
The values are guide values from the national annexes. A structural engineer must check them for the actual plot before installation.