Norms · DIN EN 1991-1-3/NA · DIN EN 1991-1-4/NA

DIN EN 1991-1-3/NA and DIN EN 1991-1-4/NA: snow and wind loads for PV mounting structures

The national annexes to DIN EN 1991-1-3 (snow) and DIN EN 1991-1-4 (wind) fix which zone a site has and which s_k and q_b follow. They produce the loads every PV mounting structure, on a roof or on open ground, is checked for. This page explains what a designer takes from them and works one example with the values of the Solispec calculation.

Updated:

Scope: what the national annexes fix

The European parts EN 1991-1-3 and EN 1991-1-4 leave the countries room in the nationally determined parameters. For Germany the national annexes fix the snow load zones (1, 1a, 2, 2a, 3) with the formula for s_k by altitude, the wind zones (1 to 4) with the basic velocity pressure q_b,0 and the wind profiles for inland, coast and islands. Which municipality belongs to which zone is in the DIBt lists by administrative boundary.

For snow the standard applies up to 1500 m above sea level; above that the building authority sets the value case by case. For wind the annex keeps the value unchanged up to 800 m, adds a factor (0.2 + H/1000) from 800 to 1100 m and requires special consideration above.

What a PV designer takes from it

  • the snow zone and wind zone of the municipality (DIBt list) and the plot’s altitude above sea level
  • s_k from the zone formula and q_b,0 from the wind zone; the tables per zone and altitude are on the page “Snow load zones and wind zones in Germany”
  • the shape coefficient μ₁ for the tilted module (0.8 up to 30° tilt, falling linearly to 0 at 60°) and the drift and sliding loads at parapets and behind rows to Annex B of EN 1991-1-3
  • the peak velocity pressure q_p(z) = c_e(z) · q_b with the site’s profile and the pressure coefficients for tilted modules
  • the design values to EN 1990 (γ_Q = 1.5 for variable actions)

The zone map in words

The snow zone follows region and altitude: Cologne, Düsseldorf and Frankfurt are in zone 1, Berlin, Hamburg and Stuttgart in zone 2, Chemnitz, Rostock and Stralsund in zone 3; Munich is in zone 1a, Passau in Bavaria’s zone 3a. For wind most of the inland is in zone 1 or 2, the coast in zone 3 (Bremen, Rostock, Flensburg) and the North Sea ports in zone 4 (Wilhelmshaven, Emden, Cuxhaven). These are the zones of the cities in Solispec’s dataset; a plot’s zone is in the DIBt lists.

Worked example: München

München lies at 524 m above sea level in snow zone 1a and wind zone 2. The calculation gives s_k = 1.11 kN/m² and q_b = 0.39 kN/m². On a module tilted 30° μ₁ = 0.8: the snow load on the module surface is 0.89 kN/m², the design value with γ_Q = 1.5 is 1.33 kN/m².

For wind the calculation gives, for terrain category II (inland, open country) and III (suburb, buildings), the peak velocity pressure q_p by height z above ground:

Height z, mc_e (II)q_p (II), kN/m²c_e (III)q_p (III), kN/m²
31.640.641.280.50
62.040.791.390.54
102.350.921.710.67

What changed and the special cases

  • The national annex on snow load applies in the 2010-12 and 2019-04 versions; since the Bavarian interior ministry’s notice of 19.01.2018 Bavaria also has zones 3a and above 3a (1.25 × zone 3)
  • In the districts the DIBt marks in the northern German lowlands (zones 1 and 2) an accidental design situation with 2.3 · s_k must also be checked; Berlin is one of them
  • High-altitude places in zone 3 (for example the Upper Harz) can have higher values; the DIBt lists s_k = 5.5 kN/m² for Hochharz localities

Checklist for the design

  • Municipality, district and the plot’s altitude above sea level noted
  • Snow zone and wind zone from the DIBt lists, not from an overview map
  • Special cases checked: zone 3a in Bavaria, the northern lowlands (2.3 · s_k), high ground above 800 m
  • s_k and q_b from formula and table, cross-checked with the page “Zones in Germany”
  • μ₁, drift behind rows and at parapets and sliding snow applied
  • Terrain category and building height set for q_p(z), pressure coefficients for tilted modules chosen
  • Design values formed with γ_Q = 1.5 and the structural design checked by an engineer

Frequently asked questions

What does DIN EN 1991-1-3/NA regulate?

The national annex on snow load: the snow load zones, the formula for s_k by altitude and the nationally determined coefficients. It applies to snow loads up to 1500 m above sea level.

What does DIN EN 1991-1-4/NA regulate?

The national annex on wind load: the four wind zones with q_b,0 from 0.32 to 0.56 kN/m², the altitude factor above 800 m and the wind profiles for inland, coast and islands.

Where do I find my plot’s zone?

In the DIBt lists of snow load zones and wind zones by administrative boundary. Zone borders run through districts; the municipality decides.

Does s_k also apply on the module?

No, s_k is the load on the ground. On the tilted module it is multiplied by μ₁, in the example 1.11 kN/m² times 0.8 gives 0.89 kN/m². Drift and sliding snow come on top.

Is the calculation on this page enough for the structural check?

No. It shows the method and guide values. A structural engineer produces the check for your site to the country’s standards.

Sources: the standards

  • DIN EN 1991-1-3/NA:2010-12, Nationaler Anhang, National festgelegte Parameter, Eurocode 1: Einwirkungen auf Tragwerke, Teil 1-3: Allgemeine Einwirkungen, Schneelasten (Zonen: Fassung 2019-04)
  • DIN EN 1991-1-4/NA:2010-12, Nationaler Anhang, National festgelegte Parameter, Eurocode 1: Einwirkungen auf Tragwerke, Teil 1-4: Allgemeine Einwirkungen, Windlasten
  • DIBt: Schneelastzonen und Windzonen nach Verwaltungsgrenzen

The values are guide values from the national annexes and the DIBt lists. A structural engineer must check them for the actual site before installation.