How many panels to connect to an inverter: DC/AC ratio calculator
Choose the panel, how many, and an inverter from the catalogue. The calculator shows the DC/AC ratio, whether the array fits the maker maximum PV input and how many panels give the typical 1.3.
Updated:
Panel power may exceed the inverter rating within the maximum PV input of the model. 18 panels of 550 W (9.9 kW) on a 8 kW inverter give a DC/AC ratio of 1.24: the typical band up to 1.3, and the PV input takes up to 10.4 kW. A guide from datasheets, not a guarantee.
How the calculator works
DC/AC = panel power in kW ÷ the AC power rating of the inverter. The panel power is the number of panels times the panel watts at STC divided by 1000. It is the ratio of two datasheet numbers, not an efficiency and not a loss.
The bands come from the Solispec designer check: below 0.7 the inverter is large for the array, up to 1.3 the typical band, from 1.3 to 1.5 the peaks at a clear noon are clipped, above 1.5 heavily overloaded. This is a guide from inverter datasheets, not a maker guarantee.
The maximum PV input that the maker gives for the model is checked separately, where the catalogue has it. Going above that number is a problem whatever the ratio: the inverter has a limit on panel power.
The calculator does not compute the yearly clipping in kWh, does not check the strings (frost voltage and MPPT input current: the strings calculator does that) and ignores orientation and shading.
Step by step
- Choose the panel. The panel watts come from the catalogue.
- Enter the number of panels. How many panels are connected to the inverter in total.
- Choose the inverter. The catalogue gives the AC power, the maximum PV input, the number of MPPT inputs and the maximum voltage.
- Read the ratio. The DC/AC value, the assessment by band and whether the array fits the maximum PV input.
- Adjust the number. The result shows how many panels give the typical 1.3 and how many the PV input allows.
Assumptions and limits
- The panel power is taken at STC (1000 W/m², 25 °C); in practice panels seldom deliver all of it.
- The bands 0.7, 1.3 and 1.5 are a guide from the designer check and inverter datasheets, not a guarantee.
- The maximum PV input comes from the catalogue; for an older entry without it the check is skipped and the result says so.
- The calculator does not compute yearly clipping and does not split the panels between MPPT inputs.
- Orientation, tilt and shading are not part of the ratio.
Worked example
Example: 18 panels of 550 W make 9.9 kW. The Deye SUN-8K-SG05LP1-EU inverter has 8 kW of AC power, so DC/AC = 9.9 / 8 = 1.24. That is the typical band (up to 1.3), and 1.3 would be 18 panels.
The PV input of this inverter takes up to 10.4 kW, that is at most 18 panels of 550 W. Going to 19 panels gives 10.45 kW (1.31): that is already above the maximum input. It has 2 MPPT inputs, and the strings are split between them by orientation.
For the Deye SUN-6K-SG05LP1-EU inverter (6 kW, PV input up to 7.8 kW) the typical 1.3 is 14 panels of 550 W, and the maximum input allows 14.
Reference table
| Panels | Power, kW | DC/AC | Assessment | Inverter PV input |
|---|---|---|---|---|
| 10 | 5.50 | 0.69 | inverter large | within |
| 12 | 6.60 | 0.83 | typical | within |
| 14 | 7.70 | 0.96 | typical | within |
| 16 | 8.80 | 1.10 | typical | within |
| 18 | 9.90 | 1.24 | typical | within |
| 19 | 10.45 | 1.31 | peaks clipped | exceeded |
| 20 | 11.00 | 1.38 | peaks clipped | exceeded |
| 22 | 12.10 | 1.51 | heavily overloaded | exceeded |
| 24 | 13.20 | 1.65 | heavily overloaded | exceeded |
Bands: up to 0.7 the inverter is large, up to 1.3 typical, up to 1.5 peaks clipped, above 1.5 heavily overloaded. The inverter maximum PV input is 10.4 kW. A guide, not a guarantee.
What to check with an engineer
- The inverter datasheet: the maximum PV input, the maximum current of each MPPT input and the conditions under which the maker allows a DC overload.
- The strings on each MPPT input: frost voltage, operating voltage inside the MPPT window and the input current (the strings calculator and the designer).
- Tilt, orientation and shading: they decide how often the peaks are really clipped.
- The grid connection terms: the permitted power by contract and the number of phases.
The calculation is preliminary. A qualified engineer must check it before installation. Codes: DBN V.1.2-2:2006 (Ukraine) and the Eurocode; for other countries — snow and wind values from the national annex, entered by hand.
Frequently asked questions
Can I connect 10 kW of panels to an 8 kW inverter?
Yes, if it stays within the maximum PV input of the model and the ratio is not too high. In the example 18 panels (9.9 kW) on 8 kW give 1.24: the typical band, and the PV input allows up to 10.4 kW. Check the maximum input, the voltage and the string currents in your inverter datasheet.
How many panels can I connect to a 6 kW inverter?
For the Deye SUN-6K-SG05LP1-EU the typical 1.3 is 14 panels of 550 W, and its maximum PV input of 7.8 kW allows 14. The strings limit the number too: frost voltage and the MPPT input current, which the strings calculator checks.
What is the DC/AC ratio of an inverter?
It is the panel power in kilowatts divided by the AC power rating of the inverter. Panels seldom run at full power (sun angle, heat, dust), so an array a little larger than the inverter keeps it busy longer. A band up to 1.3 is typical in datasheets.
What happens if the panel power is higher than the inverter power?
While the panels stay within the PV input, the inverter simply clips the peak: at a clear noon part of the panel power goes unused. Above the maker maximum input it breaks the datasheet of the model. The calculator does not estimate how much energy is lost in a year.
What DC/AC ratio is best?
There is no single optimum: it depends on tilt, orientation and climate. The calculator calls the band up to 1.3 typical and warns about clipped peaks between 1.3 and 1.5. It is a guide from the designer check and datasheets, not a guarantee.