Wind and snow load for solar mounting by city (Poland)

What snow and wind load to use for solar mounting in Warsaw, Krakow, Gdansk, Bialystok, Wroclaw and Katowice. National annex values, peak wind pressure at 10 m, a table and what drives the mounting.

By Solispec editorial3 min read

For solar mounting in Krakow the design starts from snow 1200 Pa and wind 300 Pa (national annex values). At a building height of 10 m in terrain category II the peak wind pressure is 1059 Pa. Across six Polish cities snow runs from 700 to 1600 Pa and wind from 300 to 420 Pa. The calculation is preliminary.

The numbers come from the same engine functions behind the free snow and wind calculator, so you can repeat them for your own address. What the wind does to a flat-roof row is in the ballast calculator, and the logic of fixing in the article on roof mounting.

Starting data

ItemValue
Sourcenational annex tables of Poland, values for the city
Building height10 m
Terrain categoryII
What is takencharacteristic snow S0 and wind W0, peak wind pressure Wm

Loads by city

CitySnow S0, PaWind W0, PaPeak wind Wm at 10 m, Pa
Warszawa9003001059
Kraków12003001059
Gdańsk12004201482
Białystok16003001059
Wrocław7003001059
Katowice9003001059

The peak pressure Wm is W0 times the exposure factor c_e = 2.35 for 10 m in terrain category II and the partial factor 1.5 for wind.

What the comparison shows

  • Wind. Gdańsk has 40 % more wind than Warszawa: 420 against 300 Pa. Wind sets the ballast on a flat roof and the force on a hook.
  • Snow. Białystok has 2.3 times the snow of Wrocław: 1600 against 700 Pa. Snow sets the rail, the purlins and the rafters.
  • The address. A city value is a guide. For an address in the hills or on a ridge, check the map of the national annex.

How to repeat the calculation

  1. Open the snow and wind calculator and pick the city.
  2. Set the building height to 10 m and terrain category II.
  3. Compare S0, W0 and Wm with the table above.

The calculation is preliminary. A city value is a guide, not data for one address. Altitude, snow pockets and local maps are checked by an engineer. Before installation the calculation must be checked by a qualified engineer, and the installation must be done only by a qualified electrician.

FAQ

What snow load should I use for solar panels in Krakow?

The characteristic value S0 for Krakow is 1200 Pa in the national annex. The load on the slope also depends on the tilt, so the final figure comes from the calculation of the mounting.

Where do the wind values come from?

From the national annex for the city: W0 for Krakow is 300 Pa. The peak pressure at 10 m is 1059 Pa because W0 is multiplied by the exposure factor c_e = 2.35 and the partial factor 1.5.

Which city in the table is the hardest for a mounting?

For wind Gdańsk (420 Pa), for snow Białystok (1600 Pa). The spread is large enough that the same layout needs a different amount of ballast in two cities.

StructuresNorms

News and design tips

What’s new in Solispec, changes to the standards and practical tips on designing solar power systems.

What interests you

How we handle your data: privacy policy.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate