How many roof hooks for solar panels: spacing and load

How many roof hooks 10 panels need on a 30 degree metal-tile slope in Krakow, what rafter spacing to use and the force on each hook: uplift, pressure, rail. Numbers from the Solispec engine.

By Solispec editorial3 min read

A roof of 10 panels (2 rows of 5, 30 degree slope, metal tile) in Krakow takes 36 hooks with rafters every 600 mm: each one carries 2409 N of uplift and 892 N of pressure against reference capacities of 3000 and 2500 N. It passes at 600 mm only. The calculation is preliminary.

The numbers come from the same engine functions behind the free attachments calculator, so you can repeat them with your own data. Snow and wind for a city are in the snow and wind calculator, and an overview of roof fixings is in the article on roof mounting.

Starting data

ItemValue
PlaceKrakow, wind W0 300 Pa, snow S0 1200 Pa (Polish national annex values)
Slope30°, metal tile, building height 7 m, terrain category II
Panels10 (2 rows of 5), 2350 × 1100 mm, 550 W
FixingM10 lag screw with an L-bracket and EPDM into the rafter
What changesrafter spacing: 600, 900 and 1200 mm

Result by rafter spacing

Rafter spacingHooksUplift per hook, NPressure per hook, NUplift of 3000 NPressure of 2500 NRailPasses
600 mm36240989280 %36 %12 %passes
900 mm2043371605145 %64 %26 %uplift
1200 mm1654212007181 %80 %48 %uplift

Hooks sit only on rafters, so their number follows the rafter spacing and not just the panels. The fewer the hooks, the more force on each: from 600 to 1200 mm there are 36 hooks against 16, and the uplift per hook grows 2.3 times.

What it means

  • Uplift is set by the wind. It is compared with the reference capacity of the hook, 3000 N. For a real hook use the manufacturer's data.
  • Pressure is the weight of the panels plus snow. It is compared with 2500 N.
  • The rail is checked separately for strength and deflection; the table shows the larger of the two.
  • The rafters are not calculated by the engine: an engineer checks their section and condition.

How to repeat the calculation

  1. Open the attachments calculator, pick Krakow and enter the wind and snow of the city in pascals (300 and 1200).
  2. Set metal tile, a 30° slope, 10 panels (2 rows of 5) and a building height of 7 m.
  3. Change the rafter spacing and compare the uplift and pressure per hook with the table.

The calculation is preliminary. The result covers the fixing only, not the rafters, the battens or the covering. Replace the reference 3000 / 2500 N with the manufacturer's data for the hook. Before installation the calculation must be checked by a qualified engineer, and the installation must be done only by a qualified electrician.

FAQ

How many roof hooks do solar panels need?

For 10 panels on a 30 degree metal-tile slope in Krakow, 36 hooks with rafters at 600 mm, 20 at 900 mm and 16 at 1200 mm. The number follows the rafter spacing, because hooks go only on rafters.

What spacing should roof hooks have?

A multiple of the rafter spacing. The calculator shows the load per hook for 600, 900 and 1200 mm: 2409 N of uplift at 600 mm and 5421 N at 1200 mm.

Does the roof need checking before installation?

Yes. The hook calculation says whether the fixing holds on its supports. Whether the rafters hold depends on their section, span and condition, and an engineer checks that.

StructuresNorms

News and design tips

What’s new in Solispec, changes to the standards and practical tips on designing solar power systems.

What interests you

How we handle your data: privacy policy.

Ground frame designer

Design the ground frame for your solar plant

Solispec picks the profiles and posts, checks the frame against snow and wind to the DBN and prices it down to the last bolt.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate