Solar plant: site data

Solar power plant in Kyshyn, Korostenskyi Raion, Zhytomyr Oblast

Kyshyn: 1,078 kWh per kWp a year, tilt 38° 4° east of south (PVGIS). 2.4% below the oblast median (1,104). #430 of 560 in the rayon, #1550 of 1700 in the oblast.

Korosten, the rayon centre, is 70 km away. 193 m above sea level. 60 km away: Zvyahel, the nearest bigger centre, 1,101 — 2.1% less here. Snow and wind from the nearest regional centre in the DBN — Рівне, 115 km. 13.54 m between rows, pitch 17.31 m (latitude 51.1°).

Yield of 1 kWp
1,078kWh/year
Tilt
38°4° east of south
10 kW
10,779kWh/year
Row pitch
17.31m · GCR 0.28
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,320 / 520Pa

Ground frame designer

A ground frame for a solar plant: Kyshyn

The designer opens with this place’s coordinates, latitude 51.1° for the row spacing and the DBN loads of the nearest regional centre — Рівне, 115 km: snow 1,320 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan55Feb89Mar116Apr130May137Jun136Jul133Aug108Sep77Oct34Nov28Dec

June: 137 kWh/kWp, December: 28 — 4.9 times less.

October: 77 against 81 in the oblast, 4.9% less.

Kyshyn: plants, kWh
kWpA yearJuneDecember
55,390685140
1010,7791,370280
1516,1692,055420

Snow and wind: Рівне

Example: a 10 kW ground frame

For the loads of Rivne: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Korostenskyi RaionZhytomyr Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.