Solar plant: site data

Solar power plant in Hankovytsia, Mukachivskyi Raion, Zakarpattia Oblast

Hankovytsia: 1,086 kWh per kWp a year, tilt 36° 8° east of south (PVGIS). 4.9% below the oblast median (1,141). #112 of 139 in the rayon, #467 of 613 in the oblast.

Mukachevo, the rayon centre, is 33 km away. 293 m above sea level. 33 km away: Mukachevo, the nearest bigger centre, 1,165 — 6.8% less here. Snow and wind from the nearest regional centre in the DBN — Ужгород, 55 km. 10.67 m between rows, pitch 14.54 m (latitude 48.6°).

Yield of 1 kWp
1,086kWh/year
Tilt
36°8° east of south
10 kW
10,857kWh/year
Row pitch
14.54m · GCR 0.33
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,340 / 370Pa

Ground frame designer

A ground frame for a solar plant: Hankovytsia

The designer opens with this place’s coordinates, latitude 48.6° for the row spacing and the DBN loads of the nearest regional centre — Ужгород, 55 km: snow 1,340 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan54Feb93Mar113Apr126May132Jun137Jul137Aug108Sep80Oct44Nov26Dec

July: 137 kWh/kWp, December: 26 — 5.3 times less.

November: 44 against 53 in the oblast, 17.0% less.

Hankovytsia: plants, kWh
kWpA yearJulyDecember
55,429685130
1010,8571,370260
1516,2862,055390

Snow and wind: Ужгород

Example: a 10 kW ground frame

For the loads of Uzhhorod: 11.16 kWp, 18 panels, 366 kg of steel, 12 piles, materials ≈ 48,597 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mukachivskyi RaionZakarpattia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.